Palintest Lumiso RW7 Portable Permanganate Index (CODMn) Analyzer

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Palintest
Origin United Kingdom
Model Lumiso RW7
Instrument Type Portable Photometric Analyzer
Measurement Principle Acidic Potassium Permanganate Oxidation (Standardized Colorimetric Endpoint Detection)
Range 0.5–10 mg/L as O₂
Repeatability ±3% RSD
Accuracy ±5% of reading
Limit of Detection (LOD) 0.5 mg/L
Resolution 0.01 mg/L
Analysis Time per Sample 30 minutes
Ingress Protection Rating IP67
Compliance Designed in accordance with ISO 8467:1993 (Water quality — Determination of permanganate index)

Overview

The Palintest Lumiso RW7 is a purpose-engineered portable photometric analyzer dedicated to the quantitative determination of the permanganate index (CODMn) in natural and treated waters. Unlike general-purpose COD instruments relying on dichromate-based oxidation (CODCr), the Lumiso RW7 implements the standardized acidic potassium permanganate oxidation method—fully aligned with ISO 8467:1993. This method selectively oxidizes low-molecular-weight organic compounds and readily oxidizable inorganic reductants (e.g., Fe²⁺, NO₂⁻, S²⁻) under controlled heating and acid conditions. The residual unreacted permanganate is quantified spectrophotometrically at 525 nm, and the consumed oxidant is calculated as oxygen demand (mg/L O₂). The instrument is calibrated using traceable NIST-traceable potassium permanganate standards and optimized for field deployment in surface water monitoring, raw water intake assessment, and drinking water treatment process control.

Key Features

  • IP67-rated rugged housing ensures full dust ingress protection and submersion resistance up to 1 m for 30 minutes—validated for operation in humid, rainy, or splash-prone environments including riverbanks, reservoirs, and distribution networks.
  • Dedicated CODMn optical path with temperature-compensated LED source and precision interference filter minimizes spectral drift and interferences from turbidity or colored matrixes.
  • Integrated thermal block maintains precise reaction temperature (100 °C ± 0.5 °C) during the 30-minute digestion phase, critical for reproducible permanganate consumption kinetics.
  • On-device calibration verification using certified reference solutions enables field validation of photometric performance prior to sample analysis.
  • Internal rechargeable Li-ion battery supports ≥200 measurements per charge, with real-time voltage monitoring and low-power standby mode.
  • Pre-programmed method logic enforces strict adherence to ISO 8467 timing sequences—including acid addition, heating duration, cooling interval, and endpoint measurement—reducing operator-dependent variability.

Sample Compatibility & Compliance

The Lumiso RW7 is validated for use with clarified or filtered samples meeting ISO 8467 requirements: turbidity < 5 NTU, chloride concentration < 300 mg/L (to avoid interference), and absence of suspended solids that may adsorb permanganate. It complies with national implementation guidelines for GB/T 5750.7–2023 (China’s Standard Methods for Examination of Drinking Water – Organic Contaminants) and supports regulatory reporting frameworks requiring ISO 8467-conformant data. While not a GLP/GMP-certified system, its audit-ready measurement logs (including timestamp, operator ID, calibration status, and raw absorbance values) satisfy basic QA/QC documentation needs for environmental laboratories operating under CNAS-CL01 or equivalent accreditation scopes.

Software & Data Management

Data export is supported via micro-USB connection to Windows-based desktop software (Lumiso Manager v3.2+), enabling batch export of CSV-formatted results with full metadata (sample ID, location tag, analyst code, method version, QC flags). The software supports trend charting, statistical summaries (mean, SD, CV%), and automated generation of compliance reports aligned with Chinese Ministry of Ecology and Environment (MEE) template requirements. All measurement records include immutable timestamps and are stored in non-volatile memory with write-protection against accidental overwrites.

Applications

  • Field screening of source water quality at intake points for municipal waterworks
  • Routine monitoring of reservoirs and lakes to assess organic loading trends and eutrophication risk
  • Verification of oxidation unit performance (e.g., ozone or KMnO₄ pre-oxidation) in drinking water treatment plants
  • Compliance testing for Class I–III surface water quality standards (GB 3838–2002)
  • Emergency response assessments following industrial spills involving reducing agents
  • Educational use in environmental science laboratories requiring hands-on ISO-standard methodology training

FAQ

Is the Lumiso RW7 compliant with ISO 8467:1993?
Yes—the optical detection algorithm, thermal control profile, reagent delivery sequence, and calculation engine are all designed to replicate the manual ISO 8467 procedure with metrological equivalence.
Can it measure CODCr as well?
No. The Lumiso RW7 is exclusively configured for permanganate index (CODMn). It does not support dichromate-based oxidation or heavy metal catalysts required for CODCr.
What sample pretreatment is required?
Samples must be filtered through a 0.45 µm membrane if turbidity exceeds 5 NTU; high-chloride samples (>300 mg/L Cl⁻) require blank correction or alternative methods per ISO 8467 Annex B.
How is calibration verified in the field?
A certified 2.5 mg/L and 7.5 mg/L CODMn reference standard kit (LUM-CAL-KIT) is available for daily verification; deviation >±5% triggers recalibration.
Does the device support multi-user authentication?
No—it supports user-defined operator codes (alphanumeric, up to 8 characters) for traceability but lacks biometric or password-based access control.