Palintest
Filter
Showing 1–30 of 43 results
| Brand | Palintest |
|---|---|
| Origin | United Kingdom |
| Model | 7100 |
| Instrument Type | Portable / Handheld Photometer |
| Detection Parameters | Free & Total Chlorine, Chloramines, Bromine, Ozone, Ammonia-N, Nitrate-N, Total Phosphorus, Total Nitrogen, COD, Iron (LR/HR/MR), Manganese (LR/HR), Fluoride, Silica, Copper, Zinc, Hardness, Alkalinity, pH, Turbidity, Sulfate, Cyanide, Phenol, Surfactants, Urea, and >100 additional parameters |
| Optical Wavelengths | 450 nm, 500 nm, 550 nm, 570 nm, 600 nm, 650 nm |
| Display | Backlit LCD with alphanumeric interface |
| Accuracy | ±1% T |
| Absorbance Resolution | 0.001 AU |
| Memory Capacity | 500 test results with timestamp, parameter ID, and sample ID |
| Custom Calibration Curves | Up to 30 user-defined curves |
| Connectivity | Waterproof USB port and Bluetooth 4.0 |
| Ingress Protection | IP67 |
| Power Supply | 3 × AA batteries or USB bus power |
| Dimensions | 150 × 250 × 70 mm |
| Weight | 975 g |
| Certifications | CE, UKCA, CPA (UK Water Regulations Advisory Scheme) |
| Brand | Palintest |
|---|---|
| Origin | United Kingdom |
| Model | Arsenator |
| Instrument Type | Portable |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Target Analyte | Arsenic (As) |
| Detection Time | 5 min |
| Measurement Range | 2–100 µg/L (ppb) |
| Power Supply | 9 V PP3 battery (included) |
| Compliance | Aligns with WHO Guideline Value (10 µg/L for drinking water) |
| Kit Capacity | 420 field tests per kit |
| Brand | Palintest |
|---|---|
| Origin | United Kingdom |
| Model | CD |
| Instrument Type | Portable/Handheld Water Quality Analyzer |
| Measurable Parameters | Alkalinity, Aluminum, Ammonia, Bromine, Free Chlorine, Copper, Fluoride, Hydrogen Peroxide, Iron, Manganese, Molybdate, Nitrate, Nitrite, Ozone, Phosphate, Silica, Sulfide |
| Housing Material | Acrylic-based polycarbonate disc holder with UV-stabilized acrylic color discs |
| Compliance | ASTM D1293, ISO 7888, ISO 8694, EN 27888, USP <643>, EPA Method 334.0 (Cl₂), EPA Method 350.1 (NO₃⁻) |
| Brand | Palintest |
|---|---|
| Origin | United Kingdom |
| Model | CT12 |
| Type | Portable |
| Optical System | QuadoptiX™ dual-source 860 nm LED with dual silicon photodiode detection |
| Compliance | ISO 7027 |
| Measurement Range | 0.01–1050 NTU |
| Accuracy | ±2% of reading |
| Resolution | 0.01 NTU (≤9.99 NTU), 0.1 NTU (10–99.9 NTU), 1% of reading (>100 NTU) |
| Repeatability | ±1% |
| Power Supply | 2 × AA batteries (≈10,000 measurements) or USB bus power |
| Operating Environment | 0–50 °C, ≤90% RH |
| Dimensions | 82 × 225 × 50 mm |
| Weight | 340 g |
| Ingress Protection | IP67 |
| Measurement Modes | Single, Average, Continuous, TSS estimation |
| Data Storage | Internal logging for measurements and calibration records |
| Brand | Palintest |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Hydrosense |
| Pricing | Available Upon Request |
| Brand | Palintest |
|---|---|
| Origin | United Kingdom |
| Model | Kemio Disinfection |
| Instrument Type | Portable |
| Measurement Principle | Electrochemical Sensor Technology |
| Measurable Parameters | Free Chlorine, Total Chlorine, Chlorine Dioxide, Chlorite, Peracetic Acid (PAA), Low- and High-Range Options Available |
| IP Rating | IP67 |
| Dimensions | 156 × 180 × 95 mm |
| Weight | 1012 g |
| Operating Temperature | 0–50 °C |
| Battery | Rechargeable NiMH, 2300 mAh |
| Data Storage | 1000 results on-device, 10,000 via PC software |
| Interface | Micro-USB |
| Compliance | Designed for routine compliance with WHO, EPA, EU Drinking Water Directive, and ISO 7888 / ISO 8208 standards |
| Brand | Palintest |
|---|---|
| Origin | United Kingdom |
| Model | Kemio |
| Instrument Type | Portable |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Detectable Metals | Lead (Pb), Cadmium (Cd), Copper (Cu), Arsenic(III), Arsenic(V), Total Arsenic |
| Analysis Time | ≤3 minutes per test |
| Accuracy | ±5% for aqueous samples |
| Resolution | 0.1 µg/L |
| Operating Temperature Range | 0°C–50°C |
| Display | High-contrast LCD touchscreen |
| Data Storage | 10,000 test records with full metadata |
| Dimensions & Weight | 156 mm × 180 mm × 95 mm, 1012 g |
| Battery | 2300 mAh NiMH rechargeable (Palintest-specified only) |
| Ingress Protection | IP67 |
| Compliance | US EPA Method 7000B (for Pb, Cd, Cu, As), GLP-compliant data logging, 21 CFR Part 11-ready audit trail |
| Brand | Palintest |
|---|---|
| Origin | United Kingdom |
| Model | Kemio HM |
| Instrument Type | Portable |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Detectable Metals | Lead (Pb), Cadmium (Cd), Copper (Cu), Arsenic(III), Arsenic(V), Total Arsenic |
| Measurement Range | Pb 1–100 µg/L, Cd 0.2–10 µg/L, Cu 100–2000 µg/L, As(III)/As(V)/Total As 2–250 µg/L |
| Operating Temperature | 5–35 °C (sample), 0–50 °C (ambient) |
| Display | High-contrast LCD with touch interface |
| Data Storage | 10,000 test records with full metadata |
| Dimensions & Weight | 156 × 180 × 95 mm, 1012 g |
| Battery | 2300 mAh NiMH rechargeable (Palintest-certified only) |
| Ingress Protection | IP67 |
| Connectivity | USB, QR code scanning, on-device keypad |
| Languages | English, French, Spanish, Simplified Chinese |
| Brand | Palintest |
|---|---|
| Origin | United Kingdom |
| Model | Kemio Multi |
| Instrument Type | Portable / Handheld Water Quality Analyzer |
| Detection Parameters | Free Chlorine, Total Chlorine, Chlorine Dioxide, Chlorite, Hydrogen Peroxide, Lead (Pb), Cadmium (Cd), Copper (Cu), Arsenic(III), Arsenic(V), Total Arsenic |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Operating Temperature Range | 0°C – 50°C |
| Display | High-Resolution LCD with Touchscreen Interface |
| Data Storage Capacity | 10,000 test records with full metadata |
| Dimensions (W × L × H) | 156 mm × 180 mm × 95 mm |
| Weight | 1012 g |
| Battery | 2300 mAh NiMH rechargeable battery (Palintest OEM only) |
| Power Supply | USB port or external AC adapter |
| Ingress Protection Rating | IP67 |
| Certified Methods | US EPA-approved methods for all listed analytes |
| Compliance | Designed for GLP/GMP-aligned field and lab use, supports audit-trail-ready data management |
| Brand | Palintest |
|---|---|
| Origin | United Kingdom |
| Model | Legionella ONE |
| Detection Principle | Lateral Flow Immunoassay (Colloidal Gold Conjugate) |
| Target Analyte | *Legionella pneumophila* Serogroup 1 |
| Time-to-Result | ≤25 minutes |
| Limit of Detection | 100 CFU/L |
| Regulatory Compliance | DB/T 485–2020 (China), UK HSE Legionella Control Guidance, ISO 11731:2019 (supporting methodology), GLP-aligned workflow |
| VBNC Detection Capability | Yes |
| Format Options | Syringe-based Water Sampling Kit |
| Batch Traceability | Full lot-number registration (e.g., 1005010056) |
| Intended Use | Field-deployable qualitative detection in potable water systems, cooling towers, spa pools, hot water distribution networks, and premise plumbing |
| Brand | Palintest |
|---|---|
| Origin | United Kingdom |
| Model | Legionella PRO |
| Detection Time | 25 minutes |
| Detection Limit | 100 CFU/L |
| Serogroup Coverage | Legionella pneumophila Serogroups 1–15 |
| Assay Format | Lateral Flow Immunoassay (Colloidal Gold) |
| Target | Viable but Non-Culturable (VBNC) and Culturable L. pneumophila |
| Compliance | DB/T 485–2020, UK HSE Legionella Control Guidance (L8) |
| Brand | Palintest |
|---|---|
| Origin | United Kingdom |
| Model | LTH090WS |
| Type | Portable Turbidimeter |
| Measurement Range | 0.01–1000 NTU |
| Resolution | 0.01 NTU (0.01–9.99 NTU), 0.1 NTU (10.0–99.9 NTU), 1 NTU (100–1000 NTU) |
| Accuracy | ±2% |
| Stray Light | <0.02 NTU |
| Repeatability | ±1% or ±0.01 NTU (whichever is greater) |
| Operating Temperature | 0–40 °C |
| Sample Volume | 10 mL |
| Display | 800×480-pixel capacitive touchscreen IPS panel |
| Protection Rating | IP67 dust/water resistant, IK08 impact resistant |
| Data Storage | 5,000 measurements (including 1,000 detailed records with timestamp, operator ID, and metadata) |
| Connectivity | Wi-Fi, Bluetooth 5.0, USB-C |
| Power | Rechargeable Li-ion battery (USB-C charging), supports ≥2,500 measurements per full charge |
| Calibration | 3-point calibration using SDVB or formazin standards |
| Compliant with ISO 7027 | 2016 (860 nm infrared LED light source) |
| Units | NTU, FTU, FAU |
| Measurement Modes | Rapid, Average, Continuous |
| Response Time | <7 seconds per reading |
| Brand | Palintest |
|---|---|
| Origin | United Kingdom |
| Model | Lumiso Ammonia |
| Instrument Type | Portable |
| Measurement Principle | Colorimetric (DPD-based and Nessler/Salicylate methods) |
| Wavelengths | 465 nm, 620 nm |
| Detection Ranges | Nessler method: 0.06–15.00 mg/L (0.01 mg/L res.), 0.5–50.0 mg/L (0.1 mg/L res.), 1–100 mg/L (1 mg/L res.) |
| Salicylate method | 0.01–1.00 mg/L (0.01 mg/L res.), 0.15–12/50 mg/L (0.01 mg/L res.) |
| Accuracy | ±1% T |
| Display | 226 × 138 pixel backlit LCD |
| Data Storage | 50 measurement records (including parameter, date, time, operator ID) |
| Interface | USB port + QR-code memory access |
| Protection Rating | IP67 |
| Power Supply | 3 × AA batteries |
| Dimensions | 163 × 70 × 45 mm |
| Weight | 275 g |
| Cuvette Format | 16 mm round tubes (with adapter) |
| Brand | Palintest |
|---|---|
| Origin | United Kingdom |
| Model | Lumiso Chlorine |
| Instrument Type | Portable Photometer |
| Measurement Principle | DPD Colorimetric Method (ASTM D1253, ISO 7393-2) |
| Measured Parameter | Free and Total Residual Chlorine |
| Wavelength | 530 nm |
| Optical Accuracy | ±1% T |
| Detection Range | Free/Total Cl₂: 0.01–5.00 mg/L (0.01 mg/L resolution) |
| High-Range Total Cl₂ | 1–250 mg/L (0.01 mg/L resolution) |
| Display | 226 × 138 pixel backlit LCD with icon-based UI |
| Data Storage | 50 test records (including parameter, date, time, operator ID) |
| Connectivity | USB port + QR-code-enabled memory retrieval |
| Enclosure Rating | IP67 |
| Power Supply | 3 × AA batteries |
| Dimensions | 163 × 70 × 45 mm |
| Weight | 275 g |
| Calibration Verification | Integrated absorbance check using certified reference filters |
| Compliance | Designed for GLP-compliant field and laboratory use |
| Brand | Palintest |
|---|---|
| Origin | United Kingdom |
| Model | Lumiso Expert |
| Instrument Type | Portable / Handheld Photometric Water Quality Analyzer |
| Detection Parameters | Free Chlorine, Total Chlorine, Chloramines, Chlorine Dioxide, COD (5–20,000 mg/L), Ammonia-N (0.01–100 mg/L), Nitrate-N, Nitrite-N, Phosphate (LR/HR), Total Phosphorus, Total Nitrogen, Hardness (Calcium & Total), Alkalinity (Methyl Orange & Phenolphthalein), pH, Turbidity (1–1000 NTU), Iron (LR/MR/HR), Manganese (LR/HR), Zinc, Copper, Fluoride, Chloride (0.5–50,000 mg/L), Silica (LR/HR), Sulfate, Cyanuric Acid, Ozone, Bromine, Hydrogen Peroxide (LR/HR), Sulfite, Cyanide, Urea, Color (5–500 HU), Hexavalent Chromium, Nickel, Molybdate, Aluminum, Sulfide |
| Compliance | Designed for ASTM D1253, ISO 7890-2, ISO 8467, ISO 15704, USP <643>, EN ISO 11923, and EPA-approved colorimetric methods |
| Reagent Format | Pre-measured solid reagents (50–250 tests per vial) and liquid reagents (25 tests per vial) |
| Optical System | Dual-beam LED photometry with temperature-stabilized optics and automatic wavelength selection (420–850 nm) |
| Display | 5.0″ full-color capacitive touchscreen (IP67-rated front panel) |
| Data Management | Onboard storage for ≥10,000 results with GLP-compliant audit trail, time/date stamp, operator ID, and method versioning |
| Environmental Rating | IP67 ingress protection (dust-tight, submersible to 1 m for 30 min) |
| Power | Rechargeable Li-ion battery (≥16 h typical operation), USB-C charging |
| Brand | Palintest |
|---|---|
| Origin | United Kingdom |
| Model | Lumiso Expert |
| Protection Rating | IP67 |
| Wavelengths | 430 nm, 465 nm, 530 nm, 575 nm, 620 nm (auto-selected per method) |
| Display | 16:9 full-color touchscreen, 800 × 480 px resolution |
| Photometric Accuracy | ±1% T |
| Wavelength Accuracy | ±2 nm |
| Memory Capacity | 1000 test records with timestamp, sample ID, operator info, dilution factor, and method metadata |
| Preloaded Calibration Curves | >100 (for chlorine, COD, ammonia-N, total phosphorus, total nitrogen, hardness, color, heavy metals, etc.) |
| Cuvette Compatibility | 12 mm and 25 mm round glass or plastic cuvettes |
| Power Supply | 6 × AA batteries (≈5000 measurements per charge) or AC adapter |
| Data Interface | Waterproof USB port compliant with USB 2.0 |
| Operating Languages | English, Chinese, Spanish, French, German, Portuguese |
| Compliance | Designed to support ISO 7027, ISO 8466-1, ASTM D1253, EPA 365.2, USP <643>, and EN ISO 6226 for photometric water analysis methods |
| Brand | Palintest |
|---|---|
| Origin | United Kingdom |
| Model | Lumiso Pooltest 3 |
| Instrument Type | Portable / Handheld Photometer |
| Detection Parameter | Ozone (O₃) |
| Measurement Principle | DPD Colorimetric Method (N,N-Diethyl-p-phenylenediamine) |
| Optical System | Fixed-wavelength LED-based photometry with narrow-band interference filter |
| Wavelength | 530 nm |
| Display | Backlit LCD (226 × 138 pixels) |
| Accuracy | ±1% T (Transmittance) |
| Resolution | 0.01 mg/L (for ozone in typical range) |
| Measurement Range (O₃) | 0.01–5.00 mg/L (standard range) |
| Data Storage | 50 test records (including parameter, date, time, operator ID) |
| Connectivity | USB port + QR-code-based data retrieval |
| Protection Rating | IP67 |
| Power Supply | 3 × AA batteries |
| Dimensions (L×W×H) | 163 × 70 × 45 mm |
| Weight | 275 g |
| Calibration Verification | Integrated absorbance verification using certified reference filters |
| Compliance | Designed for routine compliance monitoring per ISO 9001 QA workflows |
| Brand | Palintest |
|---|---|
| Origin | United Kingdom |
| Model | Lumiso Pooltest3 |
| Instrument Type | Portable / Handheld Photometer |
| Measured Parameters | Free Chlorine, Total Chlorine, pH, Cyanuric Acid |
| Detection Principle | DPD Colorimetric Method (Dual-Wavelength Absorption) |
| Optical System | Fixed narrow-band interference filters with auto-wavelength selection |
| Photometric Accuracy | ±1.0% T |
| Display | 226 × 138-pixel backlit LED screen with icon-driven UI |
| Protection Rating | IP67 |
| Data Storage | 50 measurement records (including date/time stamp) |
| Interface | USB port for data export and firmware updates via QR-code-linked software |
| Power Supply | 3 × AA batteries (IEC LR6) |
| Regulatory Compliance | Designed to meet ISO 7027, ASTM D1253, EN ISO 8467, and GB/T 5750.11–2023 requirements for swimming pool water testing |
| Brand | Palintest |
|---|---|
| Origin | United Kingdom |
| Model | Lumiso Pooltest6 |
| Instrument Type | Portable / Handheld Photometer |
| Detection Parameters | Free Chlorine, Total Chlorine, Ozone, Cyanuric Acid, pH, Total Alkalinity, Calcium Hardness, Urea |
| Optical System | Dual-Wavelength Automatic Selection |
| Accuracy | ±1.0% T |
| Display | 226×138-pixel LED screen |
| Protection Rating | IP67 |
| Data Storage | 50 measurement records |
| Interface | USB port for data download and firmware updates via QR code |
| Power Supply | 3 × AA batteries |
| Reagent Compatibility | Pre-filled solid reagent vials (50–250 tests per vial) |
| Certifications | Compliant with ISO 7027, EN ISO 8694, APHA Standard Methods, and GB/T 5750.11–2023 (Chinese National Standard for Swimming Pool Water) |
| Brand | Palintest |
|---|---|
| Origin | United Kingdom |
| Model | Lumiso RW7 |
| Instrument Type | Portable Photometer |
| Measurement Principle | DPD-based Spectrophotometry |
| Measured Parameters | Free Chlorine, Total Chlorine, Chlorine Dioxide, Total Hardness, Ozone, Color, pH, Permanganate Index (COD<sub>Mn</sub>) |
| Wavelengths | 465 nm & 575 nm |
| Optical Bandwidth | 10 nm |
| Wavelength Accuracy | ±2 nm |
| Display | Backlit LCD |
| Data Storage | 10 recent results |
| Power Supply | 2 × AA batteries |
| Operating Temperature | 0–50 °C |
| Enclosure Rating | IP67 |
| Dimensions | 150 × 65 × 42 mm |
| Weight | 200 g |
| Brand | Palintest |
|---|---|
| Origin | United Kingdom |
| Model | Lumiso RW7 |
| Instrument Type | Portable Photometric Analyzer |
| Measurement Principle | Acidic Potassium Permanganate Oxidation (Standardized Colorimetric Endpoint Detection) |
| Range | 0.5–10 mg/L as O₂ |
| Repeatability | ±3% RSD |
| Accuracy | ±5% of reading |
| Limit of Detection (LOD) | 0.5 mg/L |
| Resolution | 0.01 mg/L |
| Analysis Time per Sample | 30 minutes |
| Ingress Protection Rating | IP67 |
| Compliance | Designed in accordance with ISO 8467:1993 (Water quality — Determination of permanganate index) |
| Brand | Palintest |
|---|---|
| Origin | United Kingdom |
| Model | Macro 900 |
| Detection Principle | In-situ fluorescence excitation/emission (685 nm emission, 470 nm excitation) |
| Probe Type | APLite multi-parameter probe with integrated chlorophyll fluorometer electrode |
| Display | 80-character backlit LCD |
| Data Storage | 1,000 measurement records (including GPS-tagged entries) |
| GPS | 12-channel receiver, ±10 m 3D positional accuracy |
| Barometric Pressure Range | 150–1150 mbar (±1 mbar) |
| Power Supply | 5 × AA alkaline or NiMH rechargeable batteries |
| Battery Life | >20 h (alkaline), >40 h (NiMH) |
| Operating Temperature | −20 °C to +70 °C |
| Enclosure Rating | IP67 (submersible to 1 m for 30 min) |
| Dimensions | 90 × 180 × 39 mm |
| Weight | 450 g (with batteries) |
| Connectivity | USB interface with included cable |
| Cleaning System | Dual-motor brush self-cleaning probe assembly |
| Compliance | Designed for field-deployable environmental monitoring per ISO 10260, ASTM D3921, and EPA Method 445.0 (Chlorophyll a by fluorescence) |
| Brand | Palintest |
|---|---|
| Origin | United Kingdom |
| Model | Macro 900 |
| Instrument Type | Portable/Handheld Water Quality Analyzer |
| Detection Parameters | Water Temperature, Depth, Dissolved Oxygen (DO), pH, ORP, Conductivity, Resistivity, TDS, Salinity, Specific Gravity of Seawater, Ammonium/Ammonia-N, Chloride, Fluoride, Nitrate, Calcium, Turbidity, Chlorophyll-a, Phycocyanin, Phycoerythrin, Rhodamine WT Dye, Oil-in-Water, Fluorescein, CDOM/FDOM |
| Display | 80-character backlit LCD |
| Data Storage | 1,000 measurement records (including GPS-tagged data) |
| Data Output | USB interface with cable |
| GPS | 12-channel receiver, internal antenna, ±10 m 3D positional accuracy |
| Barometric Pressure Range | 150–1150 mbar (±1 mbar) |
| Power Supply | 5 × AA alkaline or NiMH rechargeable batteries |
| Battery Life | >20 h (alkaline), >40 h (NiMH) |
| Operating Temperature | −20 °C to +70 °C |
| Ingress Protection | IP67 (submersible to 1 m for 30 min) |
| Dimensions | 90 × 180 × 39 mm |
| Weight | 450 g (with batteries) |
| Ordering Code | PT 1401 Macro 900 Host Unit with Accessories |
| Brand | Palintest |
|---|---|
| Origin | United Kingdom |
| Model | AP-700 |
| Instrument Type | Portable / Handheld Water Quality Analyzer |
| Measured Parameters | Conductivity, Dissolved Oxygen (DO), Oxidation-Reduction Potential (ORP), pH, Resistivity, Salinity, Total Dissolved Solids (TDS), Seawater Specific Gravity (σt), Temperature |
| Detection Principle | Electrochemical (membrane-based DO, combination pH/ORP electrodes, conductivity cell) and Thermistor-based temperature sensing |
| Connectivity | GPS-integrated handheld host with 3 m cable |
| Probe Architecture | Modular multi-sensor probe with 4 expansion ports (2 for ISEs, 2 for optical sensors) |
| Cleaning System | Dual-motor brush cleaning mechanism |
| Compliance | Designed for field-deployable GLP-aligned data collection |
| Brand | Palintest |
|---|---|
| Origin | United Kingdom |
| Model | Macro900 with AP-700 Probe |
| Instrument Type | Portable / Handheld Water Quality Analyzer |
| Measured Parameters | Conductivity, Dissolved Oxygen (DO), Oxidation-Reduction Potential (ORP), pH, Resistivity, Salinity, Seawater Density (σₜ), Total Dissolved Solids (TDS), Temperature |
| IP Rating | IP67 (Host), IP68 (AP-700 Probe) |
| Operating Temperature | −20 °C to +70 °C (Host) |
| Data Storage | 1,000 records with GPS metadata |
| Battery Life | >20 h (alkaline), >40 h (NiMH) |
| Dimensions (Host) | 90 × 180 × 39 mm |
| Weight (Host) | 450 g |
| Dimensions (AP-700 Probe) | 290 × 48 mm (L × Ø) |
| Weight (Probe) | 725 g |
| Depth Rating (Probe) | Up to 100 m |
| GPS | 12-channel, 3D positional accuracy ±10 m |
| Barometric Pressure Range | 150–1150 mbar (±1 mbar) |
| Brand | Palintest |
|---|---|
| Origin | United Kingdom |
| Model | Micro 600 |
| Instrument Type | Portable |
| Measurement Principle | Galvanic Cell Electrochemical Probe |
| Measurement Range | 0.00–20.00 mg/L |
| Resolution | 0.01 mg/L (DO), 0.1% (saturation), 0.1 °C (temperature) |
| Accuracy | ±1.5% FS (DO and saturation), ±0.3 °C (temperature) |
| Salinity Compensation Range | 0.0–50.0 g/L |
| Atmospheric Pressure Compensation Range | 500–1499 mmHg (66.6–199.9 kPa) |
| Temperature Compensation | Automatic, 0–50 °C |
| Power Supply | 4 × AAA alkaline batteries |
| Battery Life | >100 hours |
| Dimensions | 140 × 70 × 35 mm |
| Weight | 200 g |
| Brand | Palintest |
|---|---|
| Origin | United Kingdom |
| Model | Micro 600 |
| Portability | Portable |
| Conductivity Range | 0–199.9 mS/cm |
| Detection Parameter | Single-parameter (Conductivity & Temperature) |
| Electrode Constants | K = 0.1, 1.0, 10.0 (user-selectable via keypad) |
| Calibration Points | Up to 5 points (1 per range) |
| Temperature Range | 0–80.0 °C |
| Resolution | 0.1 °C (temperature), 0.05% FS (conductivity) |
| Accuracy | ±1% FS + 1 LSD (conductivity), ±0.5 °C (temperature) |
| Temp. Compensation | Automatic or manual (0–80 °C), adjustable temperature coefficient (0.0–3.0 %/°C), reference temp. selectable (20.0–25.0 °C) |
| Display | Monochrome LCD |
| Power | 4 × AAA alkaline batteries (>100 h operation) |
| Dimensions | 140 × 70 × 35 mm |
| Weight | 200 g |
| Brand | Palintest |
|---|---|
| Origin | United Kingdom |
| Model | Micro 600 pH |
| Instrument Type | Portable |
| Parameter Types | Dual (pH + Temperature) |
| pH Measurement Range | 0.00–14.00 pH |
| pH Resolution | 0.01 pH |
| pH Accuracy | ±0.01 pH |
| pH Calibration Points | 1–5 points |
| Recognized Buffers | NIST-traceable (pH 1.68, 4.01, 6.86, 9.18, 12.45) and USP/ASTM (pH 1.68, 4.01, 7.00, 10.01, 12.45) |
| Slope Acceptance Range | 80–120% |
| Temperature Range | 0.0–100.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.5 °C |
| Temperature Compensation | Automatic or Manual (0–100 °C) |
| mV Range | −1000 to +1000 mV |
| mV Resolution | 1 mV |
| mV Accuracy | ±2 mV |
| Display | Single-line LCD |
| Power | 4 × AAA alkaline batteries (>100 h operation) |
| Dimensions | 140 × 70 × 35 mm |
| Weight | 200 g |
| Auto-off | After 17 min inactivity |
| Brand | Palintest |
|---|---|
| Origin | United Kingdom |
| Model | Micro 600 |
| Portability | Portable |
| TDS Range | 0–99.9 g/L |
| Resolution | 0.01/0.1/1 mg/L and 0.01/0.1/1 g/L |
| Accuracy | ±1% FS |
| Temperature Range | 0–100.0 °C |
| Temp. Compensation | Automatic or Manual (0–80 °C) |
| Cell Constant Options | 0.1, 1.0, 10.0 cm⁻¹ |
| TDS Conversion Factor | 0.40–1.00 (default 0.67) |
| Calibration | Up to 5-point manual per range |
| Display | Single-line LCD |
| Power | 4 × AAA alkaline batteries (>100 h life) |
| Dimensions | 140 × 70 × 35 mm |
| Weight | 200 g |
| Brand | Palintest |
|---|---|
| Origin | United Kingdom |
| Model | Micro 800 |
| Instrument Type | Portable |
| Measurement Principle | Fluorescence Quenching |
| DO Range | 0.00–50.00 mg/L |
| DO Resolution | 0.01 mg/L / 0.1% saturation |
| DO Accuracy | ±1% of reading (≤20 mg/L or ≤200% sat) / ±10% of reading (>20 mg/L or >200% sat) |
| Conductivity Range | 0–200 mS/cm |
| TDS Range | 0–100,000 mg/L |
| Salinity Range | 0–70 PSU |
| Temperature Range | −5 to +50 °C |
| IP Rating | IP67 (instrument), IP68 (probe) |
| Battery Life | >20 h (alkaline), >40 h (NiMH) |
| Data Storage | 3,000 full-parameter records with GPS and barometric metadata |
| GPS | 12-channel internal antenna, ±10 m 3D accuracy |
| Operating Temperature | −20 to +70 °C |
| Probe Submersion Depth | Up to 30 m |
| Dimensions (main unit) | 90 × 180 × 39 mm |
| Weight (with batteries) | 450 g |
| Probe Dimensions | 250 × 24 mm (L × Ø) |
| Cable Length | 3 m (extendable) |