Empowering Scientific Discovery

Palintest Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPalintest
OriginUnited Kingdom
ModelKemio
Instrument TypePortable
Detection PrincipleAnodic Stripping Voltammetry (ASV)
Detectable MetalsLead (Pb), Cadmium (Cd), Copper (Cu), Arsenic(III), Arsenic(V), Total Arsenic
Analysis Time≤3 minutes per test
Accuracy±5% for aqueous samples
Resolution0.1 µg/L
Operating Temperature Range0°C–50°C
DisplayHigh-contrast LCD touchscreen
Data Storage10,000 test records with full metadata
Dimensions & Weight156 mm × 180 mm × 95 mm, 1012 g
Battery2300 mAh NiMH rechargeable (Palintest-specified only)
Ingress ProtectionIP67
ComplianceUS EPA Method 7000B (for Pb, Cd, Cu, As), GLP-compliant data logging, 21 CFR Part 11-ready audit trail
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPalintest
OriginUnited Kingdom
ModelCD
Instrument TypePortable/Handheld Water Quality Analyzer
Measurable ParametersAlkalinity, Aluminum, Ammonia, Bromine, Free Chlorine, Copper, Fluoride, Hydrogen Peroxide, Iron, Manganese, Molybdate, Nitrate, Nitrite, Ozone, Phosphate, Silica, Sulfide
Housing MaterialAcrylic-based polycarbonate disc holder with UV-stabilized acrylic color discs
ComplianceASTM D1293, ISO 7888, ISO 8694, EN 27888, USP <643>, EPA Method 334.0 (Cl₂), EPA Method 350.1 (NO₃⁻)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPalintest
OriginUnited Kingdom
ModelKemio Disinfection
Instrument TypePortable
Measurement PrincipleElectrochemical Sensor Technology
Measurable ParametersFree Chlorine, Total Chlorine, Chlorine Dioxide, Chlorite, Peracetic Acid (PAA), Low- and High-Range Options Available
IP RatingIP67
Dimensions156 × 180 × 95 mm
Weight1012 g
Operating Temperature0–50 °C
BatteryRechargeable NiMH, 2300 mAh
Data Storage1000 results on-device, 10,000 via PC software
InterfaceMicro-USB
ComplianceDesigned for routine compliance with WHO, EPA, EU Drinking Water Directive, and ISO 7888 / ISO 8208 standards
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPalintest
OriginUnited Kingdom
ModelPotatech+
Instrument TypePortable/Handheld Water Quality Analyzer
Detection ParametersTotal Bacteria, *E. coli*, Fluoride, Nitrate, Nitrite, Ammonia-N, Free Chlorine, Chlorine Dioxide, Iron, Manganese, Chloride, Sulfate, Arsenic, pH, TDS, COD (Chemical Oxygen Demand), Turbidity
Reagent FormatPre-formulated, lyophilized or stabilized dry-reagent tablets/packs with 5-year shelf life
ComplianceDesigned to align with China’s GB/T 5750 series (Standard Methods for Examination of Drinking Water), including microbiological membrane filtration (GB/T 5750.12) and colorimetric/spectrophotometric methods (e.g., GB/T 5750.6 for metals, GB/T 5750.11 for disinfectants)
Power OptionsRechargeable 12 V battery, 12 V vehicle adapter, 220–240 V AC adapter
EnclosureIntegrated rugged carry-case with modular compartments for microbiology, physicochemical, and filtration modules
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPalintest
OriginUnited Kingdom
ModelMacro 900
Detection PrincipleIn-situ fluorescence excitation/emission (685 nm emission, 470 nm excitation)
Probe TypeAPLite multi-parameter probe with integrated chlorophyll fluorometer electrode
Display80-character backlit LCD
Data Storage1,000 measurement records (including GPS-tagged entries)
GPS12-channel receiver, ±10 m 3D positional accuracy
Barometric Pressure Range150–1150 mbar (±1 mbar)
Power Supply5 × AA alkaline or NiMH rechargeable batteries
Battery Life>20 h (alkaline), >40 h (NiMH)
Operating Temperature−20 °C to +70 °C
Enclosure RatingIP67 (submersible to 1 m for 30 min)
Dimensions90 × 180 × 39 mm
Weight450 g (with batteries)
ConnectivityUSB interface with included cable
Cleaning SystemDual-motor brush self-cleaning probe assembly
ComplianceDesigned for field-deployable environmental monitoring per ISO 10260, ASTM D3921, and EPA Method 445.0 (Chlorophyll a by fluorescence)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPalintest
OriginUnited Kingdom
ModelKemio HM
Instrument TypePortable
Detection PrincipleAnodic Stripping Voltammetry (ASV)
Detectable MetalsLead (Pb), Cadmium (Cd), Copper (Cu), Arsenic(III), Arsenic(V), Total Arsenic
Measurement RangePb 1–100 µg/L, Cd 0.2–10 µg/L, Cu 100–2000 µg/L, As(III)/As(V)/Total As 2–250 µg/L
Operating Temperature5–35 °C (sample), 0–50 °C (ambient)
DisplayHigh-contrast LCD with touch interface
Data Storage10,000 test records with full metadata
Dimensions & Weight156 × 180 × 95 mm, 1012 g
Battery2300 mAh NiMH rechargeable (Palintest-certified only)
Ingress ProtectionIP67
ConnectivityUSB, QR code scanning, on-device keypad
LanguagesEnglish, French, Spanish, Simplified Chinese
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPalintest
OriginUnited Kingdom
ModelLumiso Expert
Protection RatingIP67
Wavelengths430 nm, 465 nm, 530 nm, 575 nm, 620 nm (auto-selected per method)
Display16:9 full-color touchscreen, 800 × 480 px resolution
Photometric Accuracy±1% T
Wavelength Accuracy±2 nm
Memory Capacity1000 test records with timestamp, sample ID, operator info, dilution factor, and method metadata
Preloaded Calibration Curves>100 (for chlorine, COD, ammonia-N, total phosphorus, total nitrogen, hardness, color, heavy metals, etc.)
Cuvette Compatibility12 mm and 25 mm round glass or plastic cuvettes
Power Supply6 × AA batteries (≈5000 measurements per charge) or AC adapter
Data InterfaceWaterproof USB port compliant with USB 2.0
Operating LanguagesEnglish, Chinese, Spanish, French, German, Portuguese
ComplianceDesigned to support ISO 7027, ISO 8466-1, ASTM D1253, EPA 365.2, USP <643>, and EN ISO 6226 for photometric water analysis methods
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPalintest
OriginUnited Kingdom
ModelLTH090WS
TypePortable Turbidimeter
Measurement Range0.01–1000 NTU
Resolution0.01 NTU (0.01–9.99 NTU), 0.1 NTU (10.0–99.9 NTU), 1 NTU (100–1000 NTU)
Accuracy±2%
Stray Light<0.02 NTU
Repeatability±1% or ±0.01 NTU (whichever is greater)
Operating Temperature0–40 °C
Sample Volume10 mL
Display800×480-pixel capacitive touchscreen IPS panel
Protection RatingIP67 dust/water resistant, IK08 impact resistant
Data Storage5,000 measurements (including 1,000 detailed records with timestamp, operator ID, and metadata)
ConnectivityWi-Fi, Bluetooth 5.0, USB-C
PowerRechargeable Li-ion battery (USB-C charging), supports ≥2,500 measurements per full charge
Calibration3-point calibration using SDVB or formazin standards
Compliant with ISO 70272016 (860 nm infrared LED light source)
UnitsNTU, FTU, FAU
Measurement ModesRapid, Average, Continuous
Response Time<7 seconds per reading
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPalintest
OriginUnited Kingdom
ModelPotalab RW
Instrument TypePortable, Field-Deployable Integrated Water Quality Laboratory
Detection ParametersTotal Coliforms, Fecal Coliforms, Free Chlorine, Ammonia-Nitrogen, Fluoride, Nitrate, Nitrite, Turbidity, pH, Conductivity, TDS
Additional Expandable ParametersArsenic, Mercury, Chromium, Cadmium, COD, Chloride, Manganese, Iron
ComplianceDesigned to meet requirements of GB 5749–2022 (China’s Standard for Drinking Water Hygiene), WHO Guidelines for Drinking-water Quality (4th Ed.), and ISO/IEC 17025-aligned field testing practices
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPalintest
ModelPT 162
OriginUnited Kingdom
Instrument TypePen-style Portable Meter
Parameter TypespH, TDS, Conductivity, Salinity, Temperature
Calibration StandardNIST-traceable solutions
IP RatingIP67
Power Supply4 × 1.5 V button cells (typical battery life >150 h
Operating Temperature0–50 °C
Automatic Temperature Compensation (ATC)Yes
Measurement RangespH 0.00–14.00 (±0.01)
ResolutionpH 0.01
CalibrationUp to 5-point pH auto-calibration
TDS Conversion FactorAdjustable 0.40–1.00
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPalintest
OriginUnited Kingdom
ModelLumiso Expert
Instrument TypePortable / Handheld Photometric Water Quality Analyzer
Detection ParametersFree Chlorine, Total Chlorine, Chloramines, Chlorine Dioxide, COD (5–20,000 mg/L), Ammonia-N (0.01–100 mg/L), Nitrate-N, Nitrite-N, Phosphate (LR/HR), Total Phosphorus, Total Nitrogen, Hardness (Calcium & Total), Alkalinity (Methyl Orange & Phenolphthalein), pH, Turbidity (1–1000 NTU), Iron (LR/MR/HR), Manganese (LR/HR), Zinc, Copper, Fluoride, Chloride (0.5–50,000 mg/L), Silica (LR/HR), Sulfate, Cyanuric Acid, Ozone, Bromine, Hydrogen Peroxide (LR/HR), Sulfite, Cyanide, Urea, Color (5–500 HU), Hexavalent Chromium, Nickel, Molybdate, Aluminum, Sulfide
ComplianceDesigned for ASTM D1253, ISO 7890-2, ISO 8467, ISO 15704, USP <643>, EN ISO 11923, and EPA-approved colorimetric methods
Reagent FormatPre-measured solid reagents (50–250 tests per vial) and liquid reagents (25 tests per vial)
Optical SystemDual-beam LED photometry with temperature-stabilized optics and automatic wavelength selection (420–850 nm)
Display5.0″ full-color capacitive touchscreen (IP67-rated front panel)
Data ManagementOnboard storage for ≥10,000 results with GLP-compliant audit trail, time/date stamp, operator ID, and method versioning
Environmental RatingIP67 ingress protection (dust-tight, submersible to 1 m for 30 min)
PowerRechargeable Li-ion battery (≥16 h typical operation), USB-C charging
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWagtech
OriginUnited Kingdom
ModelPotalab
Instrument TypePortable/Handheld Water Quality Analyzer
Detection CapabilitiesMicrobiological Testing, Physicochemical Parameter Analysis
Key ComponentsPortable Incubator (dual-zone, 20–50 °C), Digital Arsenic Analyzer (2–100 µg/L, arsenical spot method), 7100 Multi-parameter Photometer (≥100 pre-programmed calibration curves, IP67 rated), Portable Turbidimeter (ISO 7027 compliant, 0.01–1000 NTU), pH/Conductivity/TDS Meter (IP67, auto-temp compensation)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPalintest
OriginUnited Kingdom
ModelLumiso RW7
Instrument TypePortable Photometer
Measurement PrincipleDPD-based Spectrophotometry
Measured ParametersFree Chlorine, Total Chlorine, Chlorine Dioxide, Total Hardness, Ozone, Color, pH, Permanganate Index (COD<sub>Mn</sub>)
Wavelengths465 nm & 575 nm
Optical Bandwidth10 nm
Wavelength Accuracy±2 nm
DisplayBacklit LCD
Data Storage10 recent results
Power Supply2 × AA batteries
Operating Temperature0–50 °C
Enclosure RatingIP67
Dimensions150 × 65 × 42 mm
Weight200 g
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPalintest
OriginUnited Kingdom
ModelLumiso Pooltest3
Instrument TypePortable / Handheld Photometer
Measured ParametersFree Chlorine, Total Chlorine, pH, Cyanuric Acid
Detection PrincipleDPD Colorimetric Method (Dual-Wavelength Absorption)
Optical SystemFixed narrow-band interference filters with auto-wavelength selection
Photometric Accuracy±1.0% T
Display226 × 138-pixel backlit LED screen with icon-driven UI
Protection RatingIP67
Data Storage50 measurement records (including date/time stamp)
InterfaceUSB port for data export and firmware updates via QR-code-linked software
Power Supply3 × AA batteries (IEC LR6)
Regulatory ComplianceDesigned to meet ISO 7027, ASTM D1253, EN ISO 8467, and GB/T 5750.11–2023 requirements for swimming pool water testing
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPalintest
OriginUnited Kingdom
ModelMicro 600
PortabilityPortable
Conductivity Range0–199.9 mS/cm
Detection ParameterSingle-parameter (Conductivity & Temperature)
Electrode ConstantsK = 0.1, 1.0, 10.0 (user-selectable via keypad)
Calibration PointsUp to 5 points (1 per range)
Temperature Range0–80.0 °C
Resolution0.1 °C (temperature), 0.05% FS (conductivity)
Accuracy±1% FS + 1 LSD (conductivity), ±0.5 °C (temperature)
Temp. CompensationAutomatic or manual (0–80 °C), adjustable temperature coefficient (0.0–3.0 %/°C), reference temp. selectable (20.0–25.0 °C)
DisplayMonochrome LCD
Power4 × AAA alkaline batteries (>100 h operation)
Dimensions140 × 70 × 35 mm
Weight200 g
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPalintest
OriginUnited Kingdom
ModelKemio Multi
Instrument TypePortable / Handheld Water Quality Analyzer
Detection ParametersFree Chlorine, Total Chlorine, Chlorine Dioxide, Chlorite, Hydrogen Peroxide, Lead (Pb), Cadmium (Cd), Copper (Cu), Arsenic(III), Arsenic(V), Total Arsenic
Detection PrincipleAnodic Stripping Voltammetry (ASV)
Operating Temperature Range0°C – 50°C
DisplayHigh-Resolution LCD with Touchscreen Interface
Data Storage Capacity10,000 test records with full metadata
Dimensions (W × L × H)156 mm × 180 mm × 95 mm
Weight1012 g
Battery2300 mAh NiMH rechargeable battery (Palintest OEM only)
Power SupplyUSB port or external AC adapter
Ingress Protection RatingIP67
Certified MethodsUS EPA-approved methods for all listed analytes
ComplianceDesigned for GLP/GMP-aligned field and lab use, supports audit-trail-ready data management
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPalintest
OriginUnited Kingdom
ModelLegionella ONE
Detection PrincipleLateral Flow Immunoassay (Colloidal Gold Conjugate)
Target Analyte*Legionella pneumophila* Serogroup 1
Time-to-Result≤25 minutes
Limit of Detection100 CFU/L
Regulatory ComplianceDB/T 485–2020 (China), UK HSE Legionella Control Guidance, ISO 11731:2019 (supporting methodology), GLP-aligned workflow
VBNC Detection CapabilityYes
Format OptionsSyringe-based Water Sampling Kit
Batch TraceabilityFull lot-number registration (e.g., 1005010056)
Intended UseField-deployable qualitative detection in potable water systems, cooling towers, spa pools, hot water distribution networks, and premise plumbing
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPalintest
OriginUnited Kingdom
ModelCT12
TypePortable
Optical SystemQuadoptiX™ dual-source 860 nm LED with dual silicon photodiode detection
ComplianceISO 7027
Measurement Range0.01–1050 NTU
Accuracy±2% of reading
Resolution0.01 NTU (≤9.99 NTU), 0.1 NTU (10–99.9 NTU), 1% of reading (>100 NTU)
Repeatability±1%
Power Supply2 × AA batteries (≈10,000 measurements) or USB bus power
Operating Environment0–50 °C, ≤90% RH
Dimensions82 × 225 × 50 mm
Weight340 g
Ingress ProtectionIP67
Measurement ModesSingle, Average, Continuous, TSS estimation
Data StorageInternal logging for measurements and calibration records
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPalintest
OriginUnited Kingdom
ModelMicro 800
Instrument TypePortable
Measurement PrincipleFluorescence Quenching
DO Range0.00–50.00 mg/L
DO Resolution0.01 mg/L / 0.1% saturation
DO Accuracy±1% of reading (≤20 mg/L or ≤200% sat) / ±10% of reading (>20 mg/L or >200% sat)
Conductivity Range0–200 mS/cm
TDS Range0–100,000 mg/L
Salinity Range0–70 PSU
Temperature Range−5 to +50 °C
IP RatingIP67 (instrument), IP68 (probe)
Battery Life>20 h (alkaline), >40 h (NiMH)
Data Storage3,000 full-parameter records with GPS and barometric metadata
GPS12-channel internal antenna, ±10 m 3D accuracy
Operating Temperature−20 to +70 °C
Probe Submersion DepthUp to 30 m
Dimensions (main unit)90 × 180 × 39 mm
Weight (with batteries)450 g
Probe Dimensions250 × 24 mm (L × Ø)
Cable Length3 m (extendable)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPalintest
OriginUnited Kingdom
ModelPK
Instrument TypePortable/Handheld Water Quality Analyzer
Detection ParametersFree Chlorine, Total Chlorine, Total Alkalinity, Calcium Hardness, Acid Demand (Cleaning Acid Strength), Chloride, Total Hardness, Nitrite, Phosphate, pH, Zinc, Ammonia-N, Sulfate, Organic Phosphorus, Quaternary Ammonium Compounds, Aluminum, Nitrate, Copper
Accessories IncludedPT 210 Kit (1 × 10 mL pipette, 1 × 100 mL sample cup, 1 × grinding rod, rigid portable case
ReagentsNot included
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPalintest
OriginUnited Kingdom
ModelPotatech9
Instrument TypePortable/Handheld Water Quality Analyzer
Detection ParametersTotal Coliforms & Fecal Coliforms, Heterotrophic Plate Count (HPC), Free Chlorine, Chlorine Dioxide, Ozone, COD (Permanganate Index), Turbidity, Color, pH
ComplianceDesigned to meet Chinese National Standards (e.g., GB/T 5750 series), ISO 9001-certified manufacturing, CE-marked for EU environmental instrumentation safety
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPalintest
OriginUnited Kingdom
ModelPT151
Instrument TypePen-style
Parameter TypeSingle-parameter
Measurement Accuracy±0.1 pH / ±1% FS (Conductivity & TDS)
Calibration StandardNIST-traceable buffer and standard solutions
Protection RatingIP67
Operating Temperature0–50 °C
Temperature CompensationAutomatic (ATC)
Power Supply4 × 1.5 V LR44/A76/V13GA button cells (>100 h battery life
Dimensions163 × 40 mm
Weight90 g
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPalintest
OriginUnited Kingdom
ModelLumiso Pooltest6
Instrument TypePortable / Handheld Photometer
Detection ParametersFree Chlorine, Total Chlorine, Ozone, Cyanuric Acid, pH, Total Alkalinity, Calcium Hardness, Urea
Optical SystemDual-Wavelength Automatic Selection
Accuracy±1.0% T
Display226×138-pixel LED screen
Protection RatingIP67
Data Storage50 measurement records
InterfaceUSB port for data download and firmware updates via QR code
Power Supply3 × AA batteries
Reagent CompatibilityPre-filled solid reagent vials (50–250 tests per vial)
CertificationsCompliant with ISO 7027, EN ISO 8694, APHA Standard Methods, and GB/T 5750.11–2023 (Chinese National Standard for Swimming Pool Water)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPalintest
OriginUnited Kingdom
ModelPotacheck 2
Instrument TypePortable/HANDHELD Water Quality Analyzer
Measured ParametersFree Chlorine, Chlorine Dioxide, Fluoride, Ammonia-N, Nitrate, Nitrite, Turbidity, Color, TDS, pH, Conductivity
Optical System (Turbidimeter)QuadoptiX™ dual 860 nm LED sources & dual silicon photodiode detectors
Turbidity Range0–1050 NTU
Turbidity Accuracy≤2%
Turbidity Resolution0.01 NTU (≤9.99), 0.1 NTU (10.0–99.9), 1% of reading (>100)
Turbidity Repeatability±1%
Turbidity ComplianceISO 7027
Photometer Wavelengths450, 500, 550, 570, 600, 650 nm (auto-selected per method)
Photometer Accuracy±1% T
Photometer Resolution0.001 AU
Data Storage100 turbidity records / 500 photometric results
ConnectivityUSB + Bluetooth 4.0
Protection RatingIP67 (all main units)
PowerAA/AAA batteries (varies by module)
Operating Environment0–50 °C, ≤90% RH
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0