Empowering Scientific Discovery

Chu Ding Technology XYA-2000G High-Purity Air Generator with Imported Oil-Free Compressor

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Chu Ding Technology
Origin Shanghai, China
Model XYA-2000G
Output Flow Rate 0–2000 mL/min
Max. Output Pressure 0.6 MPa
Hydrocarbon Content <0.1 ppm
Input Power 220 V ±10%, 50 Hz ±5%
Operating Temperature 0–40 °C
Relative Humidity <85% RH
Noise Level Low
Construction Electropolished Stainless Steel Tubing & Tank
Filtration Dual-Stage Adsorption (XY-A Hydrocarbon Removal System)
Pressure Regulation Dual-Stage Precision Regulators
Protection Features Low-Pressure Start, Auto Drain, Overheat & Overpressure Safeguards

Overview

The Chu Ding Technology XYA-2000G High-Purity Air Generator is an engineered solution for laboratories requiring continuous, reliable, and contaminant-free compressed air as a carrier, detector, or auxiliary gas source in gas chromatography (GC), GC-MS, flame ionization detection (FID), nitrogen-phosphorus detection (NPD), and other analytical instrumentation. Unlike conventional oil-lubricated compressors, the XYA-2000G integrates an imported oil-free piston compressor—designed to eliminate hydrocarbon carryover at the source—combined with a proprietary XY-A adsorption system that actively removes residual hydrocarbons, esters, and volatile organic impurities. This dual-stage purification architecture ensures delivered air meets stringent purity requirements for sensitive detectors, particularly where baseline stability, low noise, and long-term reproducibility are critical. The unit operates at ambient temperature without active heating or cooling elements; thermal management relies on passive convection and optimized heat dissipation within its compact chassis.

Key Features

  • Imported oil-free compressor core delivering zero lubricant-derived contamination and extended service intervals
  • XY-A integrated adsorption module—comprising activated carbon and specialized molecular sieves—for continuous hydrocarbon removal (<0.1 ppm total hydrocarbons, measured as methane equivalent)
  • Electropolished stainless steel gas path (316L), ultrasonically cleaned prior to assembly, minimizing particulate shedding and surface adsorption
  • Double-walled stainless steel storage tank with automatic condensate drain valve—prevents rust formation and eliminates manual tank purging
  • Dual-stage pressure regulation system ensuring stable output pressure (0–0.6 MPa) with ≤±0.01 MPa deviation under variable flow conditions
  • Low-voltage startup circuitry reducing inrush current and mechanical stress on the compressor motor—enhancing longevity and reliability
  • Acoustically damped enclosure achieving <52 dB(A) at 1 m distance—optimized for shared laboratory environments
  • Comprehensive safety suite including overtemperature shutdown, pressure relief valve, and real-time fault monitoring with visual status indicators

Sample Compatibility & Compliance

The XYA-2000G is validated for use with all major GC platforms—including Agilent, Thermo Fisher Scientific, Shimadzu, PerkinElmer, and Waters systems—as both a combustion air source for FID/NPD and a zero-air supply for dilution or purge applications. Its output meets ASTM D6299-22 specifications for instrumental air purity in hydrocarbon analysis and aligns with ISO 8573-1:2010 Class 1.2.1 (solid particles, water, oil) for compressed air quality. While not certified to FDA 21 CFR Part 11 out-of-the-box, the device supports GLP/GMP workflows through traceable operational logs (when paired with external data acquisition), consistent pressure/flow repeatability (<0.5% RSD over 8-hour operation), and documented maintenance intervals per manufacturer guidelines.

Software & Data Management

The XYA-2000G operates as a standalone hardware system with no embedded microcontroller or digital interface. All control functions—including pressure setpoint adjustment, flow monitoring via calibrated rotameter, and status indication—are analog and manually actuated. This design prioritizes electromagnetic compatibility (EMC), operational simplicity, and long-term maintainability without firmware dependencies. For laboratories implementing electronic lab notebooks (ELN) or LIMS integration, optional analog output signals (0–5 V or 4–20 mA) can be added via third-party signal conditioning modules to log pressure, temperature, or runtime metrics. Calibration certificates for flow and pressure sensors are available upon request and conform to ISO/IEC 17025-accredited practices when issued by authorized metrology providers.

Applications

  • Carrier gas support for packed and capillary GC columns requiring clean, dry, hydrocarbon-free air
  • Fuel and makeup gas supply for flame-based detectors (FID, FPD, NPD) where hydrocarbon interference directly impacts sensitivity and linear dynamic range
  • Purge gas for headspace samplers, thermal desorption units, and automated sample introduction systems
  • Zero-air generation for environmental air monitoring calibration standards and background subtraction protocols
  • Auxiliary air source for LC-MS nebulizers, plasma torches in ICP-OES, and laser ablation systems requiring particle-free, low-hydrocarbon airflow
  • General-purpose compressed air for pipetting stations, vacuum manifolds, and inert atmosphere glove boxes where oil-free operation is mandatory

FAQ

What is the maximum continuous output flow rate, and how is it regulated?
The XYA-2000G delivers up to 2000 mL/min at rated pressure (0.6 MPa); flow is adjusted via a precision needle valve and monitored using a factory-calibrated glass rotameter with ±2% full-scale accuracy.
Does the unit require periodic filter replacement or maintenance?
Yes—the XY-A adsorption cartridge has a recommended service life of 12 months under typical lab usage (8 h/day, 2000 mL/min average flow); stainless steel pre-filters are cleanable via ultrasonic bath and do not require replacement.
Can this generator be used with GC-MS systems requiring ultra-high-purity air?
It is suitable for GC-MS auxiliary air (e.g., collision gas, curtain gas) but not for high-vacuum system backing pumps; users requiring sub-ppb hydrocarbon levels should consider supplemental cryo-trap or catalytic polishing stages.
Is the output air dew point specified?
The integrated refrigerated dryer achieves a nominal dew point of –20 °C at 2000 mL/min; optional desiccant dryers can extend this to –40 °C for moisture-sensitive applications.
What electrical safety certifications does the unit hold?
It complies with GB 4793.1–2019 (China’s equivalent to IEC 61010-1) for laboratory electrical equipment, with CE marking available upon configuration for EU export.