Empowering Scientific Discovery

Chu Ding Technology DHG-9240A Precision Forced-Air Drying Oven with Stainless Steel Chamber and LCD Display

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Chu Ding Technology
Origin Shanghai, China
Model DHG-9240A
Instrument Type Precision Drying Oven
Temperature Range RT+10°C to 250°C
Temperature Uniformity ±1°C (at setpoint, empty chamber)
Temperature Resolution 0.1°C
Chamber Dimensions (W×D×H) 600 × 595 × 650 mm
External Dimensions (W×D×H) 880 × 800 × 830 mm
Chamber Volume 220 L
Power Supply AC 220 V, 50 Hz
Rated Power 2500 W
Standard Shelving 2 stainless steel trays
Timer Range 1–9999 minutes
Compliance Designed for GLP-compliant laboratory environments

Overview

The Chu Ding Technology DHG-9240A is a precision forced-air drying oven engineered for consistent thermal processing in research laboratories, quality control facilities, and industrial R&D settings. It operates on the principle of convective heat transfer via a calibrated, high-efficiency air circulation system—featuring a low-noise, high-temperature-resistant centrifugal blower and an optimized duct geometry that ensures uniform airflow distribution across the entire working chamber. Unlike natural convection ovens, this model maintains temperature stability within ±1°C across its 220 L stainless steel chamber (600 × 595 × 650 mm), validated under no-load conditions at ambient 20°C and 50% RH per IEC 60068-3-5. Its operational range spans from ambient +10°C to 250°C, making it suitable for applications requiring controlled dehydration, thermal stabilization, polymer curing, moisture loss determination (per ASTM E121–22), and dry-heat sterilization protocols where steam-free thermal treatment is mandated.

Key Features

  • Electropolished mirror-finish 304 stainless steel interior chamber with seamless, radius-rounded corners—resistant to corrosion, easy to decontaminate, and compliant with ISO 14644-1 Class 8 cleanroom-compatible surface standards.
  • Microprocessor-based PID temperature controller with 0.1°C resolution and real-time LCD display—enabling precise setpoint entry, ramp/soak programming, and continuous monitoring of actual chamber temperature.
  • Dual independent safety systems: (1) Adjustable over-temperature cut-off (limit switch) with audible/visual alarm; (2) Redundant thermal fuse integrated into heating circuitry—both conforming to EN 61000-6-2 EMC and EN 61000-6-3 emission standards.
  • Forced-air circulation architecture featuring backward-curved impeller motor rated for continuous operation at 250°C, delivering ≥20 air exchanges per minute at full load—verified via thermocouple mapping per IQ/OQ validation templates.
  • Front-access double-layer tempered glass door with silicone gasket seal—minimizing heat loss while enabling visual process monitoring without chamber opening.

Sample Compatibility & Compliance

The DHG-9240A accommodates standard laboratory sample formats including Petri dishes, weighing boats, crucibles, glassware, and metal trays up to 600 mm width. Its chamber geometry and airflow profile are validated for uniform thermal exposure across all shelf positions—critical for gravimetric moisture analysis (USP ), residual solvent testing (ICH Q5C), and pre-conditioning of test specimens prior to tensile or hardness evaluation (ASTM D618, ISO 291). The unit meets essential electrical safety requirements per GB 4793.1–2019 (equivalent to IEC 61010-1) and is designed to support GxP-regulated workflows: audit trail functionality (via optional RS485/Modbus interface), electronic record retention, and configurable user access levels align with FDA 21 CFR Part 11 expectations when integrated with validated LIMS or ELN platforms.

Software & Data Management

While the DHG-9240A operates as a standalone instrument with embedded firmware, it includes a standard RS485 communication port supporting Modbus RTU protocol for integration into centralized facility monitoring systems (e.g., DeltaV, Ignition SCADA). Optional data logging modules enable time-stamped temperature capture at user-defined intervals (1–60 sec), exporting CSV files compatible with JMP, Minitab, or Python-based statistical process control (SPC) pipelines. Firmware versioning, calibration history tracking, and event log archiving—including door-open duration, over-temp events, and power interruptions—are retained locally for ≥12 months. All configuration changes require multi-level password authentication, satisfying ALCOA+ data integrity principles for regulated environments.

Applications

  • Moisture content determination in pharmaceutical excipients and active ingredients (USP , Ph. Eur. 2.2.32)
  • Drying and conditioning of soil, aggregate, and cementitious samples prior to sieve analysis or compressive strength testing (ASTM D2216, EN 1097-5)
  • Thermal aging of polymer films and composites per ASTM D573 and ISO 188
  • Pre-baking of printed circuit board (PCB) substrates and solder paste stencils
  • Desiccation of biological specimens prior to SEM sample preparation
  • Heat treatment of calibration standards (e.g., NIST SRM 1484) in metrology labs

FAQ

What is the maximum operating temperature for the DHG-9240A?
The DHG-9240A is rated for continuous operation up to 250°C. It is not certified for use above this temperature.
Does the oven include validation documentation for IQ/OQ protocols?
Yes—factory-supplied IQ/OQ checklists, sensor calibration certificates (traceable to NIM), and airflow uniformity test reports are provided upon request for GMP-compliant installations.
Can the timer function be used for unattended overnight operation?
Yes—the 1–9999 minute programmable timer supports automatic shutdown after completion. However, remote monitoring via RS485 is recommended for extended runs.
Is the stainless steel chamber passivated per ASTM A967?
The 304 SS chamber undergoes citric acid passivation post-fabrication, with certificate of conformance available upon order.
How many shelves are included, and are additional ones available?
Two adjustable, perforated stainless steel shelves are supplied as standard. Up to four shelves can be installed; spare trays (part #CD-DHG-SH-304) are orderable separately.