- All
- Favorite
- Popular
- Most rated
| Brand | TeraSense |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Terasource-3 |
| Core Technology | Electro-vacuum backward-wave oscillator (BWO) |
| Frequency Range | 80–120 GHz (electronically tunable) |
| Tuning Range | 10 GHz |
| Linewidth | < 1 MHz |
| Output Power | 0.5–1 W (CW, frequency-dependent) |
| Dimensions | 18 × 18 × 18 cm |
| Weight | 5 kg |
| Power Supply Requirement | High-voltage DC (±15 kV), precision-stabilized |
| Cooling | Forced-air with thermal monitoring |
| Compliance | CE, RoHS, IEC 61000-6-3/6-4 |
| Brand | Rayscience |
|---|---|
| Model | QFLD-1550-100S |
| Emission Wavelength | 1550 nm |
| Output Power | 100 mW (CW) |
| Spectral Linewidth | < 3 nm (typ.) |
| Operating Temperature Range | –40 °C to +50 °C |
| Wavelength Drift Coefficient | 0.5 nm/°C |
| Rise Time | 0.5 ns |
| Fiber Type | SMF-28e+ single-mode fiber pigtail |
| Connector Options | FC/PC or FC/APC (optional) |
| Integrated Components | TEC and thermistor |
| Monitor Photodiode | Not included |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | NOVA |
| Price Range | USD 7,000–14,000 |
| Spectral Range | 185–1100 nm |
| Detector Type | Back-Illuminated FFT-CCD |
| Optical Resolution | 0.14–7.7 nm (FWHM) |
| Sensitivity | High Quantum Efficiency (QE >95% peak, 85% @ 250 nm) |
| Signal-to-Noise Ratio (SNR) | 1000:1 (single-pixel, full-well, 1 s integration) |
| Dynamic Range | 10,000:1 |
| Stray Light | <0.85% @ 600 nm |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | IO-H-1064 / IO-G-1310 / IO-F-1550 / IO-K-1064-CO (Multi-Model Platform) |
| Operating Wavelengths | 780–1550 nm |
| Max CW Power Handling | 250 mW to 20 W |
| Isolation | 27–42 dB |
| Insertion Loss | 0.3–2.0 dB |
| PDL | ≤0.25 dB (Polarization-Independent), N/A (Polarization-Dependent) |
| Extinction Ratio | >20 dB (PD), >50 dB (PI) |
| Return Loss | >50 dB |
| Fiber Types | HI1060, SMF-28e, PM980/1064, PM1300, PM1550, 780HP, SM800, SM980/1060 |
| Brand | PV Measurements |
|---|---|
| Origin | USA |
| Model | QEX12M |
| Measurement Mode | DC |
| Wavelength Range | 300–1100 nm (extendable to 1400 nm / 1800 nm) |
| Spectral Bandwidth | Adjustable via monochromator slit (default ~10 nm) |
| Wavelength Step | User-selectable (default 10 nm) |
| Repeatability | ±1% (400–1000 nm), ±2% (300–400 nm & 1000–1100 nm) |
| Sample Size Capacity | Up to 1 m × 2 m |
| Bias Light | Broadband, 0–1 SUN, Ø1.5 cm spot, with optional spectral filtering |
| Bias Voltage Range | −5 V to +40 V |
| Photocurrent Protection | 150 mA max |
| Chopper Frequency | 4–200 Hz |
| Calibration Traceability | NIST-traceable reference photodiode |
| Compliance | ASTM E1021-06, IEC 60904-8, ISO 18583 |
| Brand | RAYSCIENCE |
|---|---|
| Origin | Shanghai, China |
| Model | SCS-4000 |
| Product Type | Motorized Translation Stage |
| Pulling Accuracy | 0.2 µm |
| Pulling Speed Range | 0.2–10,000 µm/s |
| Max Pulling Distance | 50 mm |
| Fiber Clamping Diameter | φ0.1–0.5 mm |
| Flame Axial Stroke | 0–20 mm |
| Flame Scanning Speed | 0–4 mm/s |
| H₂ Flow Rate | 0–200 sccm (adjustable) |
| O₂ Flow Rate | 0–200 sccm (adjustable) |
| Detector Options | InGaAs (850–1600 nm), Si (400–1000 nm) |
| Light Source Options | 1310/1550 nm FP Laser Diode, 1 mW |
| Packaging Temperature Range | 0–130 °C |
| Power Supply | 220 V, 6 A |
| Brand | HalfMoon |
|---|---|
| Origin | Japan |
| Wavelength Range | 190–1100 nm |
| Thickness Measurement Range | 1 nm – 250 µm |
| Optical Configuration | Non-contact, Spectroscopic Interferometry |
| Detector | PDA or CCD, 512-channel, thermoelectrically cooled |
| Light Sources | Deuterium (D₂) lamp (UV), Tungsten-Halogen (W) lamp (Vis), D₂ + W combination |
| Standard Measurement Aperture | Microscope-coupled objective port |
| Compliance | Designed for ISO/IEC 17025-aligned lab environments, compatible with GLP/GMP data integrity workflows (audit trail, user access control, electronic signatures per FDA 21 CFR Part 11) |
| Brand | Keopsys |
|---|---|
| Origin | France |
| Model | PGFL-KULT Series |
| Wavelength | 532 nm |
| Pulse Energy | Up to 10 mJ |
| Peak Power | Up to 10 kW |
| Pulse Width | 1–5 ns |
| Repetition Rate | 50 kHz |
| Polarization | Linear |
| Output Type | Free-space or fiber-coupled |
| Compliance | CE, RoHS, IEC 60825-1 (Laser Safety Class 4) |
| Brand | Qioptiq |
|---|---|
| Origin | United Kingdom |
| Model | iFLEX-473nm |
| Wavelength | 473 nm |
| Output Power | 25 mW |
| Beam Mode | TEM₀₀, M² < 1.1 |
| Beam Diameter (at aperture) | 0.7 mm |
| Beam Divergence | Diffraction-limited |
| Polarization Ratio | >200:1 (vertical, ±2°) |
| Pointing Stability | <1 µrad/°C |
| Power Stability (8 h) | <0.5% RMS |
| Intensity Noise | <0.05% RMS (20 Hz – 20 MHz) |
| Dimensions | 70 mm × 40 mm × 38 mm |
| Output | Collimated free-space or single-mode polarization-maintaining fiber-coupled |
| Technology | CLM-stabilized diode laser with active temperature control |
| Custom Options | Adjustable output power, circular or shaped beam profile |
| Brand | Optogama |
|---|---|
| Origin | Lithuania |
| Manufacturer Type | OEM Manufacturer (Not Distributor) |
| Product Category | Imported Scientific Laser System |
| Model | Erbium Series |
| Output Wavelengths | 1522 nm, 1531 nm, 1550 nm, or 1602 nm |
| Output Power | Up to 500 mW CW |
| Beam Mode | TEM₀₀ (Diffraction-Limited) |
| Spectral Linewidth | FWHM < 1 nm |
| Power Stability | ±2% over 8 hours |
| Cooling | Air-Cooled |
| Gain Medium | Erbium-Doped Crystal |
| Pump Source | Diode-Pumped |
| Compliance | IEC 60825-1:2014 Class 1M / Class 3R (wavelength-dependent) |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Country of Origin | Russia |
| Model | 206 |
| Pricing | Available Upon Request |
| Brand | Spectrolight |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | FWS Poly |
| Price Range | USD 0–7,200 (approx.) |
| Spectral Range | UV–NIR (model-dependent, up to 358–900 nm) |
| FWHM Tuning Range | 3–15 nm |
| Aperture Size | 10 mm (standard), 3 mm (Laser Version) |
| Peak Transmission | >75% |
| CW Accuracy | ±0.5 nm |
| FWHM Accuracy | ±0.5 nm |
| Minimum CW Step | 0.2 nm |
| Minimum FWHM Step | 1 nm |
| Extinction Ratio | OD >6 (275–925 nm) |
| IR Cutoff | OD6 @ 930–1600 nm |
| Interface | USB 2.0 |
| Control Software | Windows-based GUI with API support (DLL/COM) |
| Brand | TTI |
|---|---|
| Origin | USA |
| Model | TIA-525I |
| Detector Type | InGaAs |
| Wavelength Range | 850–1700 nm |
| Bandwidth | DC–14 GHz (typical) |
| Gain Options | 1.0 and 10.0 |
| Max Linear Input Power | 2 mW |
| Damage Threshold | 15 mW |
| Input Interface | FC or ST |
| Output Interface | Male BNC |
| Power Supply | 9 V Li-ion battery or external DC |
| Brand | Avesta |
|---|---|
| Origin | Russia |
| Model | EFOA-SH-UB |
| Wavelengths | 1560 nm (fs), 780 nm (fs), 1100–2000 nm (supercontinuum) |
| Pulse Width | <150 fs |
| Repetition Rate | 70 ± 5 MHz |
| Output Power | >150 mW @1560 nm, >50 mW @780 nm, >130 mW @SC |
| Polarization | Linear (horizontal @1560 nm, vertical @780 nm) |
| Stability (24 h) | <1% RMS @780 nm |
| Power Supply | 110–220 VAC, 50/60 Hz |
| Operating Temperature | 22 ± 5 °C |
| Dimensions (Laser Head) | 430 × 455 × 120 mm |
| Dimensions (Control Unit) | 353 × 260 × 155 mm |
| Dimensions (SHG Unit) | 200 × 160 × 60 mm |
| Output Coupling | FC/APC fiber port (1560 nm), free-space (780 nm & SC) |
| Sync Output | SMA (TTL), Mode-Lock Status: SMA + LED |
| Brand | Solar Light |
|---|---|
| Origin | USA |
| Model | SPF-290AS |
| Wavelength Range | 290–400 nm |
| Spectral Bandwidth (FWHM) | 1.66 nm |
| Wavelength Accuracy | ±0.2% (±0.58–0.80 nm) |
| Wavelength Repeatability | ±0.25 nm |
| Absorbance Range | 0–3.2 A (Dual-Doped PMMA Method) |
| SPF Measurement Range | 1–50+ |
| Scan Time | <25 s |
| Wavelength Step Intervals | 1, 2, or 5 nm (user-selectable) |
| Light Source | Continuous-output Xenon Arc Lamp |
| Detector | High-Sensitivity Photomultiplier Tube (PMT) |
| Sample Positioning | Motorized X-Y Stage |
| Power Supply | 110 V AC / 60 Hz or 220 V AC / 50 Hz |
| Warranty | 1 year (instrument), 500 h (lamp |
| typical lamp life | ~1000 h) |
| Brand | TYDEX |
|---|---|
| Origin | Russia |
| Model | TSFPI / TSFPI-2 |
| Operating Frequency Range | 0.1–15 THz |
| Free Spectral Range (FSR) | 0.01–1.8 THz |
| Mirror Spacing | 0–9.5 mm (standard), 1.8 mm (compact variant) |
| Spectral Tuning Accuracy | ±1.25 µm |
| Clear Aperture | 52 mm |
| Optical Port Height | 110 mm |
| Dimensions (L×H×W) | 232×151×120 mm |
| Weight | 5.0 kg |
| Detector Compatibility | Tydex GP-1P photoacoustic detector |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ASOM-001 |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DG535 |
| Price | Upon Request |
| Brand | Qioptiq |
|---|---|
| Origin | UK |
| Model | iFLEX-IRIS-405 |
| Wavelength | 405 nm |
| Output Power | 25 mW |
| Beam Mode | TEM₀₀ (M² < 1.1) |
| Beam Diameter (at aperture) | 0.7 mm |
| Beam Divergence | Diffraction-limited |
| Polarization Ratio | >200:1 (Vertical ±2°) |
| Power Stability (8 h) | <0.5% RMS |
| Intensity Noise | <0.05% RMS (20 Hz – 20 MHz) |
| Pointing Stability | <1 µrad/°C |
| Dimensions | 70 mm × 40 mm × 38 mm |
| Delivery | Free-space or single-mode polarization-maintaining fiber-coupled output |
| Illumination Type | External illumination |
| Brand | Optiphase |
|---|---|
| Origin | USA |
| Model | MFI-10-50, MFI-13-50, MFI-15-50 |
| Operating Wavelength | 1064 nm, 1310 nm, 1550 nm |
| Insertion Loss | <1.5 dB |
| Optical Path Difference (OPD) Mismatch | 0 m (nominal), ±10 cm tolerance |
| Modulation Constant | 2.5 rad/V (1064 nm), 2.0 rad/V (1310 nm), 1.6 rad/V (1550 nm) |
| PZT Drive Interface | BNC |
| Max Optical Power Handling | 250 mW |
| Delay Fiber Length (standard) | 50 m (customizable from 0.5 m to 1000 m) |
| Fiber Type | HI-1060 (1064 nm), SMF-28e (1310/1550 nm) |
| Connector | FC/APC |
| Package Dimensions | 260 × 160 × 90 mm |
| Weight | ~2.7 kg |
| Brand | Covesion |
|---|---|
| Origin | United Kingdom |
| Model | SHG8-1 |
| Application | Second Harmonic Generation (SHG) |
| Pump Wavelength | 976–984 nm |
| Output Wavelength | 488–492 nm |
| Grating Period | 5.00, 5.04, 5.08 µm |
| Operating Temperature Range | 160–200 °C |
| Crystal Length | 1 mm |
| Aperture | 0.5 × 0.5 mm |
| Surface Flatness | <λ/4 |
| Parallelism | ±5 arcmin |
| Surface Quality | 20–10 scratch-dig |
| Coating | AR-coated for pump and signal bands |
| Compliance | ISO 10110 optical manufacturing standards, RoHS-compliant substrate processing |
| Brand | Lyncee Tec |
|---|---|
| Origin | Switzerland |
| Model | DHM |
| Measurement Principle | Digital Holographic Microscopy (Single- and Dual-Wavelength Interferometric Phase Imaging) |
| Vertical Resolution | 0.2 nm (single-wavelength), 50 nm (dual-wavelength) |
| Vertical Repeatability | <0.01 nm |
| Vertical Scan Accuracy | 0.1 nm |
| Lateral Resolution | 300 nm (with 1.4 NA oil immersion objective) |
| Field of View | 0.3–18 mm (objective-dependent) |
| Hologram Acquisition Speed | up to 15 fps (1024×1040 pixels), optional 30 fps |
| Reconstruction Rate | 15 fps @ 512×512, 4 fps @ 1024×1040 (single-wavelength) |
| Dual-Wavelength Scan Time | 1.5 s |
| Z-Scan Speed | 6 µm/s |
| Digital Focus Range | up to 50× depth of field |
| Illumination Intensity | <1 µW/cm² |
| Camera | 1392×1040 px, 8-bit monochrome CMOS |
| Software | Koala™ (C++/.NET-based, GLP-compliant workflow architecture) |
| Brand | TeraSense |
|---|---|
| Origin | Russia |
| Model | Ultrafast |
| Spectral Range | 0.05–0.7 THz |
| Response Time | <150 ps |
| Responsivity (typ.) | 1 V/W |
| NEP | 1 nW/Hz⁰·⁵ |
| Active Area | 3 × 3.5 mm |
| Dimensions | 23 × 29 × 6.5 mm |
| Excitation Compatibility | 200 nJ, 1 ps Laser Pulses (0.1–3 THz Band) |
| Brand | CDE ResMap |
|---|---|
| Origin | USA |
| Model | ResMap 168 |
| Automation Level | Fully Automated |
| Probe Material | Tungsten Carbide (WC) |
| Probe Lifetime | >500,000 measurements |
| Vertical Resolution for Probe Contact Optimization | 0.01 mm |
| Measurement Range | 1 mΩ/□ to 5 MΩ/□ |
| Standard Reference Wafers Included | NIST-traceable calibration set (6 pieces) |
Show next