Empowering Scientific Discovery

Chu Ding DL-01 Integrated Solvent Filtration System with Oil-Free Diaphragm Vacuum Pump

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Chu Ding
Origin Shanghai, China
Model DL-01
Pump Type DP-01 Oil-Free Diaphragm Vacuum Pump
Filter Assembly DL-1000 Borosilicate Glass Solvent Filtration Kit (1000 mL Collection Flask, 300 mL Funnel, Fritted Disc, Clamp)
Operating Vacuum ≤70 kPa
Noise Level ≤50 dB(A)
Power Supply AC 220 V / 50 Hz
Weight 4.2 kg
Dimensions (Pump) 180 × 120 × 160 mm
Dimensions (Filter Assembly) 320 × 180 × 350 mm

Overview

The Chu Ding DL-01 Integrated Solvent Filtration System is a purpose-engineered laboratory solution for rapid, contamination-free solvent and mobile phase preparation in high-performance liquid chromatography (HPLC), ultra-high-performance liquid chromatography (UHPLC), and related analytical workflows. It combines a compact DP-01 oil-free diaphragm vacuum pump with a fully assembled DL-1000 borosilicate glass filtration apparatus—including a 1000 mL heavy-walled triangular collection flask, 300 mL funnel, sintered glass frit (porosity grade G3, ~15–40 µm), and stainless-steel clamping hardware—into a single, benchtop-ready unit. The system operates on the principle of vacuum-assisted gravity filtration: negative pressure applied to the collection flask draws liquid through the fritted disc, retaining particulates, undissolved residues, and micro-aggregates that could otherwise clog analytical columns, compromise detector baseline stability, or induce backpressure spikes. Critically, the integrated vacuum also facilitates efficient dissolved gas removal—reducing bubble formation in HPLC lines and autosampler syringes—thereby enhancing method robustness and reproducibility across routine QC and research applications.

Key Features

  • Oil-free DP-01 diaphragm pump engineered for chemical compatibility: no hydrocarbon vapor contamination, eliminating risk of solvent carryover or column fouling in trace-level analyses.
  • DL-1000 filtration assembly fabricated from premium-grade borosilicate glass (Duran®/Pyrex® equivalent), certified to withstand thermal shock up to ΔT = 270 °C and autoclave sterilization (121 °C, 20 min).
  • Uniform wall thickness and ISO-standardized ground-glass joints (ISO 2955/KG 14/23) ensure leak-tight sealing and interchangeability with major international brands (e.g., Whatman, Millipore, Sartorius).
  • Integrated vibration-dampening feet and acoustic enclosure design reduce operational noise to ≤50 dB(A), supporting use in shared lab environments without acoustic interference.
  • Fritted disc conforms to ASTM E1779–21 specifications for sintered glass filter performance, with nominal pore size of 15–40 µm (G3 grade), suitable for pre-filtration prior to 0.45 µm or 0.22 µm membrane filtration.
  • Modular configuration allows optional upgrade to 2000 mL collection capacity or integration with pressure-regulated vacuum controllers for sensitive filtration of volatile or low-boiling solvents.

Sample Compatibility & Compliance

The DL-01 system is validated for use with common HPLC-grade organic solvents (acetonitrile, methanol, tetrahydrofuran), aqueous buffers (phosphate, acetate, ammonium formate), and mixed mobile phases. All wetted components—glass body, PTFE-coated clamp, and EPDM diaphragm—are chemically resistant to pH 2–12 and non-oxidizing solvents. The system supports GLP/GMP-aligned workflows: the pump’s sealed architecture prevents lubricant migration; the glassware meets ISO 3585 (borosilicate glass) and USP (glass containers); and full traceability is maintained via batch-labeled components. While not intrinsically 21 CFR Part 11 compliant, the system integrates seamlessly with validated LIMS or ELN platforms when paired with external electronic logbooks for audit-trail documentation.

Software & Data Management

The DL-01 is a standalone mechanical system with no embedded firmware or digital interface. Its operation requires no software installation, minimizing cybersecurity exposure and validation overhead. Process parameters—including filtration duration, observed vacuum level (via optional analog gauge), and solvent batch ID—are manually recorded per SOP. For laboratories requiring digital workflow integration, the system is compatible with third-party vacuum monitoring modules (e.g., Vacuubrand VACUU*VIEW) that provide RS485/Modbus output and support CSV export for inclusion in electronic lab notebooks (ELNs) or quality management systems (QMS). Calibration certificates for the optional vacuum gauge are supplied with NIST-traceable documentation.

Applications

  • HPLC/UHPLC mobile phase degassing and particulate removal prior to system priming and column equilibration.
  • Preparation of sterile-filtered reagents for cell culture media or pharmaceutical assay standards (when used with 0.22 µm membrane inserts).
  • Gravimetric analysis of suspended solids in environmental water samples (per EPA Method 160.2).
  • Colloidal separation in nanomaterial synthesis workflows where centrifugation may induce aggregation.
  • Routine QC filtration of calibration standards, reference materials, and extraction solvents in food safety and environmental testing labs.
  • Pre-filtration of aggressive solvents (e.g., chloroform, DMF) prior to membrane filtration, extending membrane life and reducing consumable costs.

FAQ

Is the DP-01 pump suitable for continuous operation?
Yes—the DP-01 is rated for intermittent duty cycles up to 30 minutes ON / 10 minutes OFF at ambient temperatures ≤35 °C. For extended use (>2 hours/day), active cooling or duty-cycle scheduling is recommended to maintain diaphragm longevity.
Can I replace the sintered glass frit with a membrane filter?
Yes—the DL-1000 funnel accepts standard 47 mm diameter membrane filters (cellulose acetate, nylon, PVDF) placed atop the frit. Use appropriate support screens to prevent membrane rupture under vacuum.
What is the maximum operating temperature for the glass assembly?
The borosilicate glass components are rated for continuous use up to 150 °C and short-term autoclaving at 121 °C. Avoid thermal shock by allowing gradual cooling after sterilization.
Does the system include vacuum tubing and connectors?
Yes—the standard DL-01 kit includes 1.5 m of reinforced silicone vacuum tubing (ID 8 mm), two hose barb fittings, and one vacuum gauge port adapter.
How often should the DP-01 diaphragm be replaced?
Under typical lab use (≤4 hrs/day, non-aggressive solvents), the EPDM diaphragm maintains performance for ≥12 months. Replacement kits (part #DP-01-DIA-REPL) are available with torque-specification tools for field service.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0