Empowering Scientific Discovery

Thermo Scientific Finnpipette Digital Multi-Channel Pipette

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Thermo Fisher
Origin USA
Manufacturer Type Authorized Distributor
Origin Category Imported
Model Finnpipette Digital Multi-Channel Pipette
Pricing Available Upon Request

Overview

The Thermo Scientific Finnpipette Digital Multi-Channel Pipette is a precision-engineered liquid handling instrument designed for high-throughput, reproducible dispensing across 8-, 12-, and 16-channel configurations. Based on positive displacement air-cushion technology, it delivers consistent volumetric accuracy and repeatability across its adjustable range (e.g., 0.5–10 µL, 1–20 µL, 5–100 µL, and other standard ranges depending on model variant), making it suitable for demanding applications in molecular diagnostics, ELISA, qPCR setup, and cell-based assays. Its lightweight construction—among the lightest multi-channel pipettes in its class—reduces operator fatigue during extended use. The instrument’s core architecture integrates mechanical robustness with ergonomic fidelity, enabling precise control without compromising user comfort or assay integrity.

Key Features

  • Ergonomic arc-shaped handle with integrated finger rests minimizes wrist flexion and ulnar deviation during repeated pipetting cycles
  • Full-instrument autoclavable design (121 °C, 20 min, saturated steam) ensures sterility compliance without disassembly—critical for aseptic workflows in GLP/GMP environments
  • Digital volume adjustment with tactile feedback and lockable setting prevents accidental volume drift during operation
  • Low-force plunger activation (≤1.5 N for aspiration, ≤2.0 N for dispensing) reduces repetitive strain injury (RSI) risk per ISO 10993-5 and EU Directive 2006/42/EC guidelines
  • Interchangeable tip cone system compatible with universal low-retention and filtered tips from major OEMs (e.g., Eppendorf, Gilson, USA Scientific)
  • Calibration traceable to NIST standards; supports in-house verification using gravimetric methods per ISO 8655-2 and ASTM E1154

Sample Compatibility & Compliance

The Finnpipette Digital Multi-Channel Pipette accommodates aqueous buffers, viscous reagents (e.g., glycerol-containing solutions up to 40% v/v), and low-surface-tension liquids (e.g., ethanol/water mixtures) when used with appropriate tip selection and technique optimization. It complies with IEC 61010-1 for electrical safety and meets RoHS 2011/65/EU requirements. For regulated environments—including clinical diagnostics (CLIA, CAP), pharmaceutical QC (USP , FDA 21 CFR Part 11), and environmental testing (EPA Method 500 series)—the device supports audit-ready documentation via optional calibration logs and user access control protocols when integrated with validated LIMS platforms.

Software & Data Management

While the Finnpipette Digital operates as a standalone mechanical-electronic instrument without embedded firmware or Bluetooth connectivity, its design enables full compatibility with third-party laboratory informatics systems. Volume settings, usage logs, and maintenance records can be manually entered into electronic lab notebooks (ELNs) compliant with 21 CFR Part 11. Calibration certificates include unique serial-numbered traceability, digital signature fields, and expiration dates aligned with ISO/IEC 17025-accredited service providers. Routine performance verification data may be exported in CSV format for statistical process control (SPC) analysis using JMP or Minitab.

Applications

  • High-density microplate preparation for immunoassays (ELISA, Western blotting, multiplex cytokine profiling)
  • Genomic workflow automation support—including cDNA synthesis, library normalization, and NGS sample indexing
  • Cell culture seeding and media supplementation across 96-well and 384-well formats
  • Environmental water testing (e.g., nutrient analysis, microbial enumeration)
  • Food safety screening (pathogen detection, mycotoxin quantification, allergen testing)
  • Regulatory-compliant reference material dilution in metrology laboratories

FAQ

Is the entire pipette body autoclavable?
Yes—the complete unit, including shaft, tip cone, and digital display housing, is rated for full-cycle autoclaving at 121 °C for 20 minutes without degradation of accuracy or structural integrity.
What volume ranges are available for multi-channel configurations?
Standard offerings include 0.5–10 µL (8/12/16-channel), 1–20 µL, 5–100 µL, 10–200 µL, and 20–1000 µL; each calibrated per ISO 8655-2 Annex B.
Does it meet FDA 21 CFR Part 11 requirements?
The device itself is not software-driven and thus falls outside Part 11 scope; however, its calibration documentation, usage logs, and maintenance history fully support Part 11-compliant recordkeeping when managed within validated ELN/LIMS environments.
Can it be serviced by certified third-party providers?
Yes—Thermo Fisher maintains an authorized service network globally, and calibration/maintenance procedures are documented in publicly accessible technical bulletins (TB-FINN-MC-2023 Rev. D).