Empowering Scientific Discovery

PerkinElmer Clarus 600 Gas Chromatograph (Refurbished)

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand PerkinElmer
Origin USA
Model Clarus 600
Instrument Type Laboratory Gas Chromatograph
Temperature Control Range Ambient to 450 °C
Maximum Ramp Rate 140 °C/min (programmable up to 160 °C/min)
Cooling Rate 450 °C to 50 °C in <2 min
Carrier Gas Flow Range 0–1200 mL/min
Carrier Gas Pressure Range 0–970 kPa
Injector Max Temp 450 °C (PSS injector up to 500 °C)
Injector Pressure Range 0–970 kPa
Injector Total Flow Range 0–1200 mL/min
FID Detection Limit <3×10⁻¹² g C/sec (n-nonane, S/N = 2:1)
Oven Operating Range (with cryogenic cooling) –90 °C to 450 °C
Temperature Programming 9 ramps / 10 steps
Injector Types Supported Packed Column (PKD), Split/Splitless Capillary (CAP), Programmable Temperature Vaporization (PSS)

Overview

The PerkinElmer Clarus 600 Gas Chromatograph (refurbished and fully requalified) is a high-performance, laboratory-grade GC system engineered for precision, reproducibility, and operational efficiency in regulated and research environments. Based on robust capillary and packed column separation principles, the Clarus 600 employs precise electronic pressure control (EPC) and advanced oven thermal management to deliver rapid, repeatable separations across diverse sample matrices. Its core architecture integrates a thermally optimized column oven capable of ultra-fast heating and active cooling—enabling cycle times significantly shorter than conventional GC platforms. Designed for compatibility with flame ionization detection (FID), the system meets routine quantification requirements in environmental, petrochemical, pharmaceutical, and food safety applications where hydrocarbon profiling, residual solvent analysis, and volatile organic compound (VOC) characterization are critical.

Key Features

  • Ultra-Rapid Thermal Cycling: Column oven cools from 450 °C to 50 °C in under 2 minutes using integrated air-assisted cooling; maximum ramp rate of 140 °C/min (user-configurable up to 160 °C/min) ensures minimal dwell time between injections.
  • Electronic Pressure & Flow Control (EPC/EFC): Dual independent EPC modules provide real-time, digital regulation of carrier gas pressure (0–970 kPa) and total flow (0–1200 mL/min) with <±0.01 kPa stability—critical for method transfer and retention time reproducibility.
  • Modular Injector Architecture: Supports three injector types: packed column (PKD), standard split/splitless (CAP), and programmable temperature vaporizing (PSS) injectors—each rated to 450 °C (PSS to 500 °C), enabling broad volatility range coverage without hardware swaps.
  • Intuitive Touchscreen Interface: Integrated 7-inch color touchscreen with context-sensitive menus allows full method setup, run control, and diagnostics without external PC dependency—reducing training overhead and minimizing operator error.
  • FID Performance: Hydrogen-air flame ionization detector with optimized jet geometry and low-noise electrometer delivers sub-picogram carbon sensitivity (10⁷.
  • Cryogenic Compatibility: Optional liquid nitrogen or mechanical cryo-cooling support extends oven operating range to –90 °C, facilitating high-resolution separation of early-eluting volatiles and light gases.

Sample Compatibility & Compliance

The Clarus 600 accommodates liquid, gaseous, and headspace-derived samples via multiple inlet configurations—including standard syringe injection, autosampler integration (e.g., PerkinElmer TurboMatrix), and optional purge-and-trap or thermal desorption interfaces. It complies with analytical workflows aligned with ASTM D3606, EPA Method 8021B, USP , and ISO 17025 requirements when operated under documented SOPs. All refurbished units undergo comprehensive factory recalibration, leak testing, and performance verification per PerkinElmer’s Certified Refurbishment Protocol—ensuring conformance with GLP/GMP data integrity expectations. Audit trail functionality in TotalChrom software supports 21 CFR Part 11 compliance when deployed with appropriate IT controls and user access management.

Software & Data Management

Controlled by PerkinElmer TotalChrom® Chromatography Data System (CDS), the Clarus 600 supports full acquisition, processing, reporting, and archival workflows. TotalChrom provides validated sequence building, peak integration with customizable baselines and retention time locking, multi-level user permissions, and electronic signature capability. Raw data files (.chd) are stored in vendor-neutral formats compatible with LIMS integration. The software includes built-in tools for calibration curve generation (linear, quadratic, weighted), system suitability assessment (tailing factor, resolution, %RSD), and automated report templating compliant with ISO/IEC 17025 reporting clauses. Remote monitoring and method synchronization across instrument networks are supported via TotalChrom Enterprise Server.

Applications

  • Environmental analysis: BTEX, PAHs, chlorinated solvents, and gasoline range organics (GRO) per EPA SW-846 methods.
  • Petrochemical QA/QC: Hydrocarbon type analysis (HTA), simulated distillation (SimDis), and refinery gas composition.
  • Pharmaceutical: Residual solvent testing (ICH Q3C), excipient purity, and extractables/leachables screening.
  • Food & flavor: Volatile aroma profiling, lipid oxidation products (hexanal, pentanal), and ethanol quantification.
  • Forensics & toxicology: Blood alcohol content (BAC), drug metabolite screening, and ignitable liquid residue identification.

FAQ

Is this a factory-refurbished unit or third-party reconditioned?
All Clarus 600 systems are refurbished at PerkinElmer-certified service centers using OEM parts and calibrated against traceable NIST standards.
Does the system include a working FID and associated gases?
Yes—each unit ships with a fully tested FID, along with certified gas regulators and fittings for H₂, air, and carrier gas (He or N₂). Gas purity specifications (≥99.999%) are documented in the qualification report.
Can the Clarus 600 be upgraded to support mass spectrometry?
Yes—the system features a standard GC-MS interface port and is compatible with PerkinElmer’s Torion T-9 portable MS or SQ 8 series benchtop quadrupole mass spectrometers.
What documentation accompanies the instrument?
Each unit includes a Certificate of Requalification, full maintenance history, calibration certificates (oven, injector, detector), and a complete set of electronic manuals and software licenses.
Is remote technical support available post-installation?
Yes—customers receive 12 months of PerkinElmer Priority Support, including remote diagnostics, method troubleshooting, and firmware updates via secure portal access.

InstrumentHive