PerkinElmer Optima 8000 ICP-OES Spectrometer (Refurbished)
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | Optima 8000 |
| Instrument Type | Full-Spectrum Simultaneous ICP-OES |
| Detection Limit | 1 ppm |
| Precision (RSD) | ≤1.5% |
| Short-Term Stability (1 hr) | RSD <1% |
| Long-Term Stability (4 hr) | RSD <2% |
| Wavelength Range | 160–900 nm |
| Optical Resolution | ≤0.003 nm (pixel resolution at 200 nm) |
Overview
The PerkinElmer Optima 8000 is a full-spectrum simultaneous inductively coupled plasma optical emission spectrometer (ICP-OES) engineered for high-throughput, multi-element trace metal analysis in demanding laboratory environments. Operating on the fundamental principle of atomic emission spectroscopy, the instrument atomizes and excites liquid samples in a high-temperature argon plasma (~6,000–10,000 K), causing constituent elements to emit characteristic wavelengths of ultraviolet and visible light. A high-efficiency echelle optical system—combined with a solid-state CCD detector—captures the entire spectral range from 160 nm to 900 nm in a single exposure, enabling true simultaneous detection of up to 70+ elements without sequential scanning or wavelength repositioning. Designed for robustness and analytical reproducibility, the Optima 8000 delivers sub-part-per-trillion (ppt) to part-per-trillion (ppq) detection capability across most elements when paired with optimized sample introduction systems (e.g., concentric nebulizers, cyclonic spray chambers, and cooled desolvation modules). Its modular architecture supports routine operation in regulated quality control (QC) laboratories as well as method development in research settings.
Key Features
- Full-spectrum simultaneous acquisition using an advanced echelle grating and back-thinned, thermoelectrically cooled CCD detector for maximum quantum efficiency and low dark current.
- High-resolution optics delivering ≤0.003 nm pixel resolution at 200 nm—critical for resolving complex spectral overlaps in environmental and metallurgical matrices.
- Robust RF generator with automatic impedance matching and plasma stabilization algorithms ensuring consistent excitation conditions over extended run times.
- Integrated peristaltic pump and intelligent sample introduction system supporting both aqueous and organic solvent-based analyses with optional micro-nebulization capabilities.
- Self-diagnostic hardware monitoring—including plasma status, gas flow integrity, detector temperature, and lamp stability—with real-time alerts and loggable event history.
- Refurbishment protocol compliant with PerkinElmer’s original factory service specifications, including full optical alignment, detector calibration, plasma torch conditioning, and comprehensive performance verification against NIST SRM standards.
Sample Compatibility & Compliance
The Optima 8000 accommodates a broad range of sample types, including aqueous digests (EPA Methods 200.7, 200.8, 6010D), acid-leached solids, filtered environmental waters, biological fluids (after appropriate dilution and matrix-matching), and high-purity acids used in semiconductor manufacturing. It meets key regulatory requirements for elemental quantification under ASTM D5191, ISO 11885, USP /, and EN 14802. When operated within validated methods and configured with audit-trail-enabled software, the system supports GLP and GMP compliance frameworks. All refurbished units undergo rigorous testing for spectral purity, background equivalence, and linearity across five orders of magnitude (0.1–10,000 µg/L), with documented RSD ≤1.5% for triplicate measurements and long-term stability verified at <2% RSD over four consecutive hours.
Software & Data Management
Instrument control, data acquisition, and quantitative analysis are managed via WinLab32 v6.x or Syngistix™ for ICP-OES software—both fully compatible with Windows 10/11 platforms and compliant with FDA 21 CFR Part 11 requirements when deployed with electronic signature and audit trail configurations. The software provides customizable calibration curves (linear, quadratic, or weighted), internal standard correction, inter-element correction (IEC) for spectral interference modeling, and automated QC checks (e.g., continuing calibration verification, bracketing standards, drift correction). Raw spectral data are stored in vendor-neutral formats (e.g., .csv, .txt) and can be exported for third-party statistical analysis or LIMS integration via ODBC or HL7 interfaces. All software licenses included with refurbished systems are fully transferable and activated under valid PerkinElmer maintenance agreements.
Applications
- Environmental testing labs performing multi-element analysis of wastewater, soil extracts, and airborne particulate matter per EPA and ISO protocols.
- Pharmaceutical quality control laboratories verifying elemental impurities in active pharmaceutical ingredients (APIs) and excipients per ICH Q3D guidelines.
- Geochemical and mining laboratories quantifying major, minor, and trace elements in rock digests and exploration samples.
- Food safety laboratories screening for toxic metals (As, Cd, Pb, Hg) and essential nutrients (Ca, Mg, Fe, Zn) in raw materials and finished products.
- Materials science research groups characterizing dopants, contaminants, and stoichiometric ratios in catalysts, ceramics, and battery-grade precursors.
- Contract testing organizations requiring high uptime, method portability, and regulatory traceability across client-specific SOPs.
FAQ
Is this a factory-refurbished unit or dealer-refurbished?
This Optima 8000 has undergone a certified refurbishment process aligned with PerkinElmer’s OEM technical specifications, including full optical recalibration, plasma source validation, and detector quantum efficiency mapping.
What documentation accompanies the instrument?
Each unit ships with a Certificate of Performance Verification, detailed refurbishment report, original operator manuals (digital and printed), and calibration records traceable to NIST SRMs.
Can the system be upgraded to support newer software versions?
Yes—hardware compatibility with Syngistix v5.5+ is confirmed; upgrade paths require a valid PerkinElmer software maintenance contract.
What is the expected operational lifetime post-refurbishment?
Based on component wear analysis and historical field data, properly maintained units typically deliver ≥5 years of reliable service in routine QC environments.
Does the system include a computer and peripherals?
A dedicated, pre-configured Windows workstation with dual monitors, licensed software, and all necessary cables and interface cards is supplied as part of the turnkey package.