Empowering Scientific Discovery

Kanomax Model 6822 Portable Vane Anemometer for Cleanroom Air Velocity Monitoring

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Kanomax
Model 6822
Type Vane (Propeller) Anemometer
Measurement Range 0.2–20.0 m/s
Resolution 0.01 m/s
Accuracy ±3% of reading or ±0.1 m/s (whichever is greater)
Operating Temperature −20 to +100 °C
Operating Humidity 5.0–95.0 %RH
Probe Diameter 70 mm
Power Supply 3 × AA batteries
Battery Life Approx. 150 hours
Dimensions (W×H×D) 81 × 165 × 38 mm
Weight 175 g (including batteries)
Air Volume Calculation Yes (user-input duct geometry)
Display Backlit LCD
Data Hold & Min/Max/Avg Functions Yes

Overview

The Kanomax Model 6822 is a portable, handheld vane anemometer engineered for precise air velocity measurement in controlled environments—particularly pharmaceutical cleanrooms, semiconductor fabrication facilities, medical device manufacturing suites, and ISO Class 5–8 classified spaces. It operates on the principle of rotational torque conversion: airflow imparts angular momentum to a calibrated 70-mm-diameter vane probe, whose rotational speed is transduced into a linear velocity signal via an optoelectronic sensor. This mechanical sensing architecture delivers stable, low-drift performance across wide temperature and humidity ranges without requiring thermal compensation algorithms—critical for validation-compliant airflow verification during HVAC commissioning, filter integrity testing, and routine environmental monitoring per ISO 14644-3 and EU GMP Annex 1 requirements.

Key Features

  • High-resolution digital display with backlight for low-light cleanroom corridor or glovebox use
  • Vane probe optimized for low-turbulence sampling at supply diffusers, return grilles, and laminar flow hoods
  • Real-time air volume calculation (in cfm) when user inputs duct cross-section geometry (rectangular, circular, or custom polygon)
  • Data-hold, min/max/average tracking, and auto-zero functions for repeatable spot-checking
  • Rugged ABS housing with IP54-rated ingress protection against dust and incidental moisture
  • Low-power design enabling >150 hours of continuous operation on standard AA alkaline cells
  • Compact form factor (81 × 165 × 38 mm) and lightweight construction (175 g) for ergonomic one-handed use during extended audits

Sample Compatibility & Compliance

The Model 6822 is validated for use in non-explosive, non-corrosive ambient air streams typical of regulated clean environments. Its −20 to +100 °C operating range supports sterilization cycle verification (e.g., steam-in-place duct monitoring) and cold-chain storage area qualification. While not intrinsically safe, it complies with IEC 61000-4 electromagnetic immunity standards for industrial instrumentation. The device meets general requirements for periodic calibration traceability to NIST-traceable reference standards; users are advised to perform annual recalibration per ISO/IEC 17025-accredited laboratories. Documentation supports audit readiness for FDA 21 CFR Part 11 (when used with compliant data logging accessories), EU GMP Annex 1 (Section 4.38–4.42 on airflow uniformity), and ISO 14644-3:2019 Annex B test protocols.

Software & Data Management

The Model 6822 operates as a standalone instrument with no embedded memory or USB interface. However, its analog output (0–1 V DC proportional to velocity) and optional RS-232 serial module (sold separately) enable integration with third-party SCADA systems, LIMS platforms, or custom validation databases. When paired with Kanomax’s optional PC software (e.g., KAN-LOG v3.x), users can generate timestamped CSV reports compliant with ALCOA+ principles (Attributable, Legible, Contemporaneous, Original, Accurate). Audit trail functionality—including operator ID, calibration date, and environmental conditions—is maintained externally via integrated electronic logbooks adhering to 21 CFR Part 11 Annex A guidance for electronic records.

Applications

  • Supply air velocity mapping across HEPA-filtered laminar flow workstations (ISO 14644-3 Section B.4)
  • Return air grille balancing during HVAC system recommissioning
  • Filter face velocity verification pre- and post-integrity testing (e.g., DOP/PAO challenge)
  • Environmental monitoring during aseptic processing line qualification (EU GMP Annex 1 §4.40)
  • Validation of unidirectional airflow patterns in isolators and RABS enclosures
  • Temperature-compensated velocity trending in high-heat clean manufacturing zones (e.g., wafer bake ovens)

FAQ

Is the Model 6822 suitable for ISO Class 5 cleanroom certification?
Yes—it meets the minimum resolution (0.01 m/s) and accuracy (±3%) requirements specified in ISO 14644-3:2019 for airborne particle concentration and airflow uniformity testing.
Can it measure air velocity inside small-diameter ducts?
The 70-mm vane probe requires ≥3× probe diameter straight-run upstream and downstream for laminar flow development; for ducts <210 mm, use with caution and apply ISO 14644-3 Annex C correction factors.
Does it support GLP/GMP-compliant data export?
Standalone unit does not store data; compliance requires external logging hardware/software validated per 21 CFR Part 11 Annex A.
What is the recommended calibration interval?
Annual calibration is recommended; more frequent intervals (e.g., quarterly) are required if used in critical process verification or after physical impact.
Can the same probe be used for both supply and exhaust measurements?
Yes—the vane design is bidirectional and insensitive to flow direction; however, ensure probe orientation aligns with nominal airflow vector for optimal signal-to-noise ratio.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0