Empowering Scientific Discovery

KANOMAX 6006 Handheld Thermal Anemometer

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand KANOMAX
Origin Liaoning, China (Distributed by Authorized KANOMAX Representative)
Model 6006
Instrument Type Thermal Anemometer
Velocity Range 0.01–20.0 m/s
Velocity Accuracy ±5% of reading
Velocity Resolution ±5% of reading
Temperature Range −20 to +70 °C
Temperature Accuracy ±1.0 °C
Power Supply 4 × AA batteries
Dimensions 60 × 120 × 34 mm
Weight 180 g
Operating Ambient Temperature −20 to +70 °C

Overview

The KANOMAX 6006 Handheld Thermal Anemometer is a compact, field-deployable instrument engineered for precise real-time measurement of air velocity and ambient temperature in HVAC commissioning, indoor air quality (IAQ) assessments, cleanroom validation, and industrial ventilation surveys. Based on constant-temperature anemometry (CTA), the device employs a fine-wire thermistor probe heated to a fixed differential above ambient; airflow-induced convective cooling is quantified to derive velocity via calibrated thermal transfer models. Its low-end sensitivity down to 0.01 m/s enables detection of subtle drafts and laminar flow conditions—critical for ISO 14644-1 classified environments—while the upper limit of 20.0 m/s accommodates high-velocity duct traverses and fume hood face velocity checks. Integrated temperature compensation circuitry actively corrects for thermal drift across the full operating range (−20 to +70 °C), ensuring metrological consistency without manual recalibration between seasonal or site-specific thermal shifts.

Key Features

  • Simultaneous dual-parameter acquisition: air velocity and ambient temperature, displayed concurrently on a high-contrast LCD
  • Interchangeable probe design compliant with KANOMAX’s modular sensor platform—supports future upgrades including extended-range or high-temperature probes
  • Compact ergonomic form factor (60 × 120 × 34 mm, 180 g) optimized for one-handed operation during extended field use
  • Built-in temperature compensation algorithm maintaining velocity accuracy across −20 to +70 °C ambient conditions
  • Low-power architecture powered by four standard AA cells, delivering >20 hours of continuous operation under typical usage
  • Robust housing rated for industrial environments, with IP54-equivalent ingress protection against dust and water splashes

Sample Compatibility & Compliance

The KANOMAX 6006 is validated for use in non-corrosive, non-explosive air streams containing particulate concentrations within ISO 16890 Class ePM10 limits. It is not intended for saturated vapor, high-humidity condensing environments (>95% RH sustained), or aggressive chemical atmospheres (e.g., chlorine, ammonia, or solvent vapors). The instrument conforms to IEC 61000-4 electromagnetic compatibility standards and meets CE marking requirements for portable measuring instruments. While not certified to specific regulatory mandates (e.g., FDA 21 CFR Part 11), its measurement traceability aligns with ISO/IEC 17025 principles when used within a documented QA/QC framework—supporting GLP-compliant data collection in laboratory and facility validation workflows.

Software & Data Management

The 6006 operates as a standalone field instrument with no proprietary software dependency. All measurements are stored in internal memory (up to 99 data sets) with timestamp and unit annotation. Data export is facilitated via manual transcription or optional IR interface (KANOMAX IR-Link adapter, sold separately), enabling direct transfer to Excel-compatible CSV files for audit-ready reporting. No cloud connectivity or firmware update capability is embedded—consistent with ISO 13485-aligned design philosophy prioritizing deterministic behavior and long-term calibration stability over feature creep.

Applications

  • HVAC system balancing and duct traverse verification per ASHRAE Guideline 12 and ISO 16813
  • Cleanroom airflow uniformity mapping in pharmaceutical manufacturing (ISO 14644-3 Annex B)
  • Local exhaust ventilation (LEV) capture velocity assessment per HSE HSG258 and OSHA Technical Manual Section III: Chapter 5
  • Classroom and office IAQ baseline studies supporting WELL Building Standard v2 Air Concept
  • Validation of laminar flow hoods and biosafety cabinets per NSF/ANSI 49 and EN 12469
  • Energy audit pre- and post-retrofit airflow comparisons under ASHRAE Standard 202

FAQ

Does the KANOMAX 6006 support data logging with time-stamped intervals?

No—it retains up to 99 manually triggered readings with timestamps but lacks programmable interval logging.
Is the probe calibrated to NIST-traceable standards?

Each unit ships with a manufacturer’s calibration certificate referencing KANOMAX’s ISO/IEC 17025-accredited calibration lab; full NIST traceability requires optional third-party certification.
Can the 6006 measure velocity in CO₂-enriched or inert gas environments?

No—the thermal transfer model assumes standard air composition (78% N₂, 21% O₂); accuracy degrades in non-air gas matrices without reconfiguration.
What is the recommended recalibration interval?

Annual calibration is advised under routine use; more frequent verification is required after mechanical shock, exposure to condensation, or operation beyond specified temperature limits.
Is the device suitable for outdoor wind speed measurement?

It is designed for indoor and sheltered semi-outdoor applications only; unshielded outdoor use introduces turbulence-induced uncertainty exceeding ±5% specification.