Empowering Scientific Discovery

Luchuang GC60 Advanced Gas Chromatograph with Electronic Pressure Control (EPC), Precision Valve-Actuated Pneumatic System, and Multi-Detector Support

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Luchuang
Origin Shandong, China
Manufacturer Type Direct Manufacturer
Instrument Type Laboratory Gas Chromatograph
Model GC60
Temperature Control Range Ambient +8 °C to 450 °C
Max Ramp Rate 65 °C/min
Cool-down Time ≤3.5 min (300 °C → 100 °C at 25 °C ambient)
Temperature Stability ±0.01 °C
Programmed Temperature Steps Up to 99
Inlet Max Temp 450 °C
Inlet Pressure Range 0–1000 kPa
Carrier Gas Flow Range 0–1200 mL/min
Carrier Gas Pressure Range 0–1000 kPa
Detector Compatibility FID, TCD, ECD, FPD, NPD (up to 4 detectors simultaneously)

Overview

The Luchuang GC60 is a high-performance, laboratory-grade gas chromatograph engineered for precision, reliability, and regulatory-compliant operation in demanding analytical environments—particularly within petrochemical, refinery, and quality control laboratories. It employs a dual-mode pneumatic architecture combining electronically controlled pressure regulation (EPC) with high-precision mechanical valve actuation for robust, repeatable carrier gas delivery. The system utilizes capillary or packed column separation, supported by advanced thermal management and real-time digital feedback loops to maintain temperature uniformity across the oven, inlet, and detector zones. Its core measurement principle relies on differential partitioning of volatile analytes between a mobile phase (inert carrier gas) and a stationary phase (column coating), followed by selective detection based on physicochemical properties—enabling quantitative and qualitative analysis of complex hydrocarbon mixtures, sulfur compounds, halogenated organics, and trace contaminants per ASTM D3606, D5599, ISO 6425, and USP . Designed for continuous operation under GLP/GMP-aligned workflows, the GC60 integrates seamlessly into validated laboratory information management systems (LIMS) and supports full audit trail generation.

Key Features

  • 10-inch capacitive touchscreen interface with intuitive, icon-driven method setup—eliminating keyboard dependency and reducing operator training time.
  • Modular oven design featuring optimized internal heat exchange geometry and dual-sensor PID control, achieving ±0.01 °C thermal stability and uniformity across 100–350 °C (±1% gradient).
  • Triple-inlet configuration support (up to 3 independently controllable inlets), compatible with split/splitless, on-column, PTV, and gas-tight syringe injection modes; six inlet options available for application-specific optimization.
  • Multi-detector capability: simultaneous installation of up to four detectors—including FID, TCD, ECD, FPD, and NPD—with independent temperature zoning and signal conditioning.
  • Electronic pressure and flow control (EPC/EFC) across all pneumatic modules, replacing analog gauges with digital readouts calibrated to NIST-traceable standards; pressure resolution: 0.1 kPa, flow resolution: 0.1 mL/min.
  • Enhanced cooling architecture enabling sub-4-minute cooldown from 300 °C to 100 °C—critical for high-throughput batch analysis in refinery QA/QC labs.

Sample Compatibility & Compliance

The GC60 accommodates gaseous, liquid, and volatile solid samples via standard 10 μL syringes, headspace vials (HS-GC), or automated liquid samplers (ALS). It is routinely deployed for ASTM D1319 (hydrocarbon types), D2425 (naphthas), D5186 (diesel aromatics), and EPA Method 8021B (halogenated VOCs). All hardware and firmware comply with IEC 61000-6-3 (EMC), UL 61010-1 (safety), and support 21 CFR Part 11-compliant data integrity through role-based user authentication, electronic signatures, and immutable audit trails. Optional IQ/OQ documentation packages are available for GxP validation.

Software & Data Management

The GC60 operates with Luchuang ChromaLink™ v4.x workstation software—a Windows-based platform supporting remote instrument monitoring, real-time chromatogram streaming, and centralized method library management. It includes integrated calibration curve fitting (linear, quadratic, weighted), peak integration with baseline correction algorithms (valley-to-valley, tangent skim), and customizable report templates compliant with ISO/IEC 17025 reporting requirements. Raw data files (.cdf) are stored in open-format structure, ensuring long-term readability and third-party software interoperability (e.g., OpenLab CDS, Chromeleon).

Applications

  • Petrochemical QA/QC: Benzene/toluene/xylene (BTX) quantification, olefin/paraffin ratio determination, gasoline oxygenate analysis (MTBE, ETBE).
  • Environmental testing: Chlorinated pesticides (e.g., lindane, DDT), PCB congeners, BTEX in soil/water extracts.
  • Pharmaceutical residual solvent screening per ICH Q3C guidelines using headspace-GC/FID.
  • Food & flavor analysis: Volatile organic compound profiling in essential oils and fermented products.
  • Industrial gas purity verification (e.g., H₂, N₂, O₂, CO₂) via TCD with dual-column configuration and column backflush capability.

FAQ

Does the GC60 support 21 CFR Part 11 compliance?
Yes—when configured with ChromaLink™ v4.x and enabled audit trail logging, user access controls, and electronic signature modules.

Can the instrument operate with both capillary and packed columns simultaneously?
Yes—the TCD module supports single-column, dual-column, or capillary-column configurations with column backflush and dual reference flow paths.

What is the minimum detectable concentration for chlorinated compounds using the ECD?
The ECD achieves ≤1×10⁻¹⁴ g/mL detection limit for γ-HCH (lindane) under optimized conditions, per EPA 8081B validation protocols.

Is remote diagnostics and firmware updates supported?
Yes—via secure TLS-enabled web interface; firmware patches and calibration updates are distributed through authenticated Luchuang support portal.

How many temperature program steps can be defined in a single method?
Up to 99 ramp-hold steps, with individual setpoint resolution of 0.1 °C and time resolution of 1 second.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0