| Brand | Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | A-3000 |
| Output Flow Rate | 3000 mL/min |
| Maximum Output Pressure | 0.6 MPa |
| Hydrocarbon Content | <0.1 ppm (as total hydrocarbons) |
| Oxygen Content | 20–22% (v/v) |
| Moisture Content | <3 ppm (v/v) |
| Total Hydrocarbons (THC) | <1 ppm (v/v) |
| Pressure Stability | ≤0.003 MPa |
| Rated Power | 185 W |
| Noise Level | ≤42 dB(A) |
| Dimensions (L×W×H) | 450 × 250 × 365 mm |
| Brand | Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | AHS-2036Plus |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Vial Heating Range | Ambient to 260 °C |
| Valve Temperature Control Range | Ambient to 260 °C |
| Sample Loop Volume | 1 mL |
| Temperature Control Accuracy | ±0.1 °C |
| Sample Capacity | 30 or 36 vials |
| Vial Size | 20 mL (customizable to 10 mL) |
| Brand | Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | ATDS-800 |
| Instrument Type | Single-Stage Thermal Desorber |
| Automation Level | Semi-Automatic |
| Primary Desorption Temperature Range | 50–380 °C |
| Valve Injection Zone Temperature Range | Ambient to 220 °C |
| Transfer Line Temperature Range | Ambient to 220 °C |
| Cold Trap Temperature | −30 °C |
| Temperature Control Accuracy | < ±0.1 °C |
| Desorption Recovery Rate | >99% (compound-dependent) |
| Sample Position Count | 1 |
| Sample Tube Dimensions | ≤6.5 mm OD, ≥120 mm length |
| Brand | Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | ATDS-8100 |
| Instrument Type | Dual-stage thermal desorber |
| Automation Level | Semi-automatic |
| Primary Desorption Temp Range | 50–380 °C |
| Valve Injection Temp Range | Ambient to 260 °C |
| Transfer Line Temp Range | Ambient to 220 °C |
| Cryo-Trap Temp Range | –30 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Desorption Recovery Rate | >80% |
| Sample Position Count | 1 |
| Brand | Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Dual-Stage Thermal Desorber |
| Automation Level | Fully Automated |
| Primary Desorption Temp Range | 50–380 °C |
| Secondary Desorption Temp Range | 150–380 °C |
| Valve & Transfer Line Temp Range | Ambient to 260 °C / Ambient to 220 °C |
| Cryo-Trap Temp Range | −30 to 30 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Desorption Recovery Rate | ≥90% |
| Sample Positions | 20 |
| Brand | Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Petrochemical Industry |
| Temperature Control Range | 0–450 °C |
| Maximum Ramp Rate | 65 °C/min |
| Cooling Rate | 300 °C to 100 °C in ≤3.5 min (at 25 °C ambient) |
| Carrier Gas Flow Range | 0–1200 mL/min (7-program segments) |
| Carrier Gas Pressure Range | 0–970 kPa (7-program segments) |
| Injector Maximum Temperature | 450 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Temperature Control Range | Ambient +8 °C to 450 °C |
| Maximum Ramp Rate | 65 °C/min |
| Cooling Rate | 3.5 min (300 °C → 100 °C at 25 °C ambient) |
| Temperature Stability | ±0.01 °C |
| Programmable Temperature Steps | Up to 99 |
| Oven Time Setting Range | 0–9999 min |
| Carrier Gas Flow Range | 0–1200 mL/min |
| Carrier Gas Pressure Range | 0–1000 psi |
| Injector Max Temp | 450 °C |
| Injector Pressure Set Range | 0–1000 psi |
| Injector Total Flow Set Range | 0–1200 mL/min |
| Detector Options | FID, TCD, ECD, FPD, NPD |
| Simultaneous Detectors | Up to 4 |
| Injector Ports | Up to 3 configurable ports |
| Available Injector Types | 6 modular configurations |
| Brand | Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC-9870 TVOC |
| Temperature Control Range | 25–450 °C |
| Maximum Ramp Rate | 60 °C/min |
| Cooling Rate | 1 °C/min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–1000 kPa |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–1000 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Temperature Control Range | Ambient + 6 °C to 399 °C |
| Temperature Ramp Rate | 0.1–40 °C/min |
| Cooling Rate | 300 °C to 50 °C in ~6 min |
| Carrier Gas Flow Range | 0–600 mL/min |
| Carrier Gas Pressure Range | 0–0.4 MPa |
| Injector Maximum Temperature | 400 °C |
| Injector Pressure Setting Range | 0–0.4 MPa |
| Total Injector Flow Setting Range | 0–600 mL/min |
| Column Oven Dimensions | 260 × 250 × 150 mm (L×H×D) |
| Weight | 50 kg |
| Power Consumption | 2500 W |
| Display | 5.7″ LCD (320 × 240), Bilingual (English/Chinese) |
| Brand | Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Portable Gas Chromatograph |
| Application Field | Power Industry – Transformer Oil Dissolved Gas Analysis (DGA) |
| Oven Temperature Range | Ambient +4°C to 450°C |
| Maximum Ramp Rate | 0.1–50°C/min |
| Cooling Time | ~3 min (200°C to 100°C) |
| Carrier Gas Flow Control Range | 0–1200 mL/min (7 programmable segments) |
| Carrier Gas Pressure Control Range | 0–970 kPa (7 programmable segments) |
| Injector Max Operating Temperature | 450°C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Temperature Stability | ±0.02°C |
| Programmable Temperature Steps | Up to 32 oven ramps |
| EPC Precision | Pressure ±0.001 psi |
| Dimensions | 400 mm × 300 mm × 400 mm (L×W×H) |
| Brand | Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable Gas Chromatograph |
| Application Field | Coal Mining Industry |
| Temperature Control Range | Ambient +4°C to 450°C |
| Maximum Ramp Rate | 0–60°C/min |
| Cooling Rate | 200°C → 100°C in ~3 min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min (7 programmable segments) |
| Carrier Gas Pressure Range & Control | 0–970 kPa (7 programmable segments) |
| Injector Max Operating Temperature | 450°C |
| Injector Pressure Setting Range | Up to 450°C |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Column Oven | Supports up to four packed columns |
| Detector Compatibility | FID, TCD, FPD, methanizer, optional MS interface |
| Brand | Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC-9870T |
| Temperature Control Range | Ambient + 6°C to 399°C |
| Ramp Rate | 0.1–40°C/min |
| Cooling Time | ~6 min (300°C to 50°C) |
| Carrier Gas Flow Range | 0–600 mL/min |
| Carrier Gas Pressure Range | 0–0.4 MPa |
| Injector Maximum Temperature | 400°C |
| Injector Pressure Setting Range | 0–0.4 MPa |
| Injector Total Flow Setting Range | 0–600 mL/min |
| Column Oven Dimensions | 260 × 250 × 150 mm (L×H×D) |
| Weight | 50 kg |
| Power Consumption | 2500 W |
| Voltage | 220 V ±10% |
| FID Detection Limit | ≤2×10⁻¹² g/s (n-hexadecane) |
| TCD Sensitivity | ≥10,000 mV·mL/mg (n-hexadecane) |
| ECD Detection Limit | ≤1×10⁻¹⁴ g/mL (⁶³Ni source) |
| Max Operating Temperature (FID) | ≤450°C |
| Programmed Temperature Ramping | 8-step linear |
| Temperature Stability | ±0.1°C |
| Temperature Gradient Uniformity | ±1% (100–350°C) |
| Data Storage Capacity | 20 chromatographic methods |
| Display | 10-inch LCD with bilingual (Chinese/English) interface |
| Brand | Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC60 |
| Temperature Control Range | Ambient +8 °C to 450 °C |
| Max Ramp Rate | 65 °C/min |
| Cool-down Time | ≤3.5 min (300 °C → 100 °C at 25 °C ambient) |
| Temperature Stability | ±0.01 °C |
| Programmed Temperature Steps | Up to 99 |
| Inlet Max Temp | 450 °C |
| Inlet Pressure Range | 0–1000 kPa |
| Carrier Gas Flow Range | 0–1200 mL/min |
| Carrier Gas Pressure Range | 0–1000 kPa |
| Detector Compatibility | FID, TCD, ECD, FPD, NPD (up to 4 detectors simultaneously) |
| Brand | Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC70 |
| Temperature Control Range | Ambient +8 °C to 450 °C |
| Maximum Ramp Rate | 65 °C/min |
| Cooling Rate | 3.5 min (300 °C → 100 °C at 25 °C ambient) |
| Temperature Stability | ±0.01 °C |
| Programmed Temperature Steps | Up to 99 |
| Carrier Gas Flow Range | 0–1200 mL/min |
| Carrier Gas Pressure Range | 0–1000 psi |
| Inlet Temperature Max | 450 °C |
| Inlet Pressure Setpoint Range | 0–1000 psi |
| Inlet Total Flow Setpoint Range | 0–1000 mL/min |
| EPC Precision | ±0.001 psi (pressure), ±0.001 mL/min (flow) |
| Inlet Configurations | Up to 3 simultaneously installed, 6 optional inlet types |
| Detector Capacity | 1–4 modular detectors (FID, TCD, ECD, FPD, NPD) |
| FID Detection Limit | ≤2×10⁻¹² g/s (n-hexadecane) |
| TCD Sensitivity | ≥10,000 mV·mL/mg (n-hexadecane) |
| ECD Detection Limit | ≤1×10⁻¹⁴ g/mL (63Ni source) |
| Brand | Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC80 |
| Temperature Control Range | 20–450 °C |
| Maximum Ramp Rate | 0–60 °C/min |
| Cooling Rate | 1 °C/min (from 300 °C to 100 °C in ≤3.5 min at 25 °C ambient) |
| Carrier Gas Flow Range | 0–1200 mL/min |
| Carrier Gas Pressure Range | 0–1000 psi |
| Injector Max Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–1000 psi |
| Injector Total Flow Setting Range | 0–1000 mL/min |
| EPC Precision | ±0.001 psi (pressure), ±0.001 mL/min (flow) |
| Programmed Temperature Vaporizing (PTV) Support | Yes |
| Max Temperature Ramping Steps | 99 |
| Max Hold Time per Step | 6000 min |
| Temperature Stability | ±0.01 °C |
| Temperature Uniformity | ±1% (100–350 °C) |
| Brand | Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Gas Chromatography Autosampler |
| Maximum Sample Capacity | 60–120 vials |
| Minimum Injection Volume | 0.1–5 mL |
| Standard Loop Volume | 1000 µL |
| Positioning Accuracy | <0.3 mm |
| Motion Architecture | XYZ Three-Axis |
| Needle Wash Mode | XYZ Three-Axis Cleaning |
| Integrated Purge Function | Yes |
| Observation Window | Yes |
| Built-in Filtration Module | Yes |
| Brand | Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Benchtop Ion Chromatograph |
| Model | IC-3000 |
| Pump Pressure Range | 0–35 MPa (0–5000 psi) |
| Flow Rate Range | 0.00–10.00 mL/min |
| Eluent Flow Rate | 0.1–3.0 mL/min |
| Max Operating Pressure | 35 MPa |
| Operating Temperature Range | 30–60°C (86–140°F) |
| Temperature Stability | ±0.1°C |
| Eluent Concentration Range | 0.1–100 mM (varies by eluent chemistry) |
| Brand | Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Semi-Automatic |
| Sample Vial Capacity | 20 positions |
| Vial Size | 20 mL (10 mL optional |
| Sample Zone Temperature Range | Ambient to 300 °C (1 °C increment, ±0.5 °C accuracy) |
| Valve System Temperature Range | Ambient to 180 °C (1 °C increment, ±0.5 °C accuracy) |
| Transfer Line Temperature Range | Ambient to 200 °C (1 °C increment, ±0.5 °C accuracy |
| Pressure-Controlled Sampling Range | 0–0.4 MPa (continuously adjustable) |
| Purge Flow Rate | 0–400 mL/min (continuously adjustable) |
| Precision | RSD ≤3% (measured with 200 ppm ethanol in water) |
| Dimensions | 420 × 248 × 380 mm |
| Weight | ~15 kg |