Cole-Parmer 05629-22/40 Digital Flow Monitor and Totalizer with Dual Power Options

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Cole-Parmer
Model 05629-22 (Battery-Powered) / 05629-40 (AC/DC-Powered)
Accuracy ±0.5% of reading
Display Upper 4-digit LCD (flow rate), Lower 8-digit LCD (totalizer)
Power 05629-22 — dual internal lithium batteries (4-year nominal life)
Dimensions 05629-22 — 3.875" W × 3.875" H × 3.875" D
Operating Temperature –10 to 55 °C (14 to 131 °F)
Relay Output 2 SPDT, 125 VAC / 30 VDC, 5 A max
Analog Output 4–20 mA (non-isolated)
Pulse Output Optically isolated, sink current ≤5 mA
Display Update Rate 200 ms
Hysteresis 2% of setpoint
Sensor Compatibility Roto-X and Metalex flow sensors only (Roto-X low-flow sensors excluded)
Environmental Rating NEMA 4X-rated enclosure (IP65 equivalent)

Overview

The Cole-Parmer 05629-22/40 Digital Flow Monitor and Totalizer is a dual-configuration instrumentation platform engineered for reliable, high-fidelity gas flow monitoring and cumulative volume tracking in industrial, laboratory, and pilot-scale process environments. Designed around a microprocessor-based architecture, the system supports two distinct operational modes: battery-powered standalone operation (model 05629-22) for remote or hazardous locations where wired power is unavailable or impractical, and AC/DC-powered continuous-duty control (model 05629-40) for fixed installations requiring analog output, relay actuation, and real-time process interfacing. Both variants implement independent calibration pathways for instantaneous flow rate and integrated totalization—ensuring metrological integrity across dynamic operating conditions. The device operates on the principle of pulse counting from compatible turbine- or vortex-based gas flow sensors (Roto-X and Metalex series), translating sensor-generated frequency signals into calibrated volumetric flow rates (e.g., SLPM, SCFH) and cumulative totals (e.g., standard liters, cubic feet). Its design complies with fundamental requirements for field-deployable instrumentation under IEC 61000-6-2 (immunity) and IEC 61000-6-3 (emissions), and supports traceable calibration workflows aligned with ISO/IEC 17025 documentation practices.

Key Features

  • Dual-power flexibility: 05629-22 operates on two replaceable lithium batteries (4-year nominal service life at 25 °C); 05629-40 accepts universal 12–24 VAC/VDC input with 50/60 Hz compatibility
  • Independent calibration architecture: Flow rate scaling and totalizer accumulation are decoupled—enabling recalibration of one parameter without affecting the other
  • High-contrast dual-display interface: Upper 4-digit LCD for real-time flow rate; lower 8-digit LCD for totalized volume, both with auto-adjusting contrast and low-battery indicator (05629-22)
  • Configurable analog and digital outputs: 4–20 mA current loop (non-isolated), optically isolated pulse output (≤5 mA sink), and two programmable SPDT relays (125 VAC / 30 VDC, 5 A)
  • On-device scalability: Front-panel 6-position range selector dial and included unit/multiplier adhesive labels support rapid re-ranging for different gases or pipe configurations
  • NEMA 4X-rated polycarbonate enclosure (IP65 equivalent): Resistant to dust ingress, water jets, and corrosion—suitable for washdown or outdoor mounting
  • Non-volatile memory retention: All configuration parameters, alarm thresholds, and accumulated totals persist through power loss or battery replacement

Sample Compatibility & Compliance

The 05629-22/40 is validated exclusively for use with Cole-Parmer–certified Roto-X and Metalex gas flow sensors. These sensors employ mechanical rotation or vortex shedding principles to generate proportional frequency outputs, which the monitor processes using factory-trimmed linearization algorithms. Roto-X low-flow variants are explicitly incompatible due to signal amplitude and frequency response mismatches. The system meets general-purpose industrial safety requirements per UL 508 and CSA C22.2 No. 14, and its relay outputs conform to EN 61810-1 for electromechanical switching devices. While not intrinsically safe, the unit may be deployed in Class I, Division 2 environments when installed per NEC Article 500 guidelines. Calibration traceability follows NIST-traceable procedures; end-user recalibration is supported via front-panel keypad entry of span and zero offsets, with audit trail capability enabled when integrated into validated systems adhering to FDA 21 CFR Part 11 (with appropriate electronic signature controls).

Software & Data Management

No proprietary software is required for basic operation—the 05629-22/40 is fully configured via its front-panel keypad and dual-line alphanumeric LCD (05629-40 only). However, the analog (4–20 mA) and pulse outputs enable seamless integration into distributed control systems (DCS), SCADA platforms, or PLC-based data acquisition networks. The 200 ms display update rate ensures responsive visualization of transient flow events, while non-volatile EEPROM preserves all user-defined settings—including relay setpoints, hysteresis (2% of setpoint), and totalizer reset history—across power cycles. For GxP-regulated applications, the device supports configurable alarm logging (via relay state changes) and can be paired with external dataloggers compliant with ASTM E2500 and Annex 11 principles. Audit trails must be maintained externally, as the unit itself does not embed time-stamped electronic records.

Applications

  • Medical gas delivery verification in hospital utility rooms and anesthesia equipment validation
  • Calibration verification of mass flow controllers (MFCs) in semiconductor tool purge lines
  • Batch gas consumption tracking in chemical synthesis reactors and fermentation vessels
  • Leak testing and pressure decay analysis using controlled purge flows
  • Environmental chamber air exchange rate monitoring (e.g., ISO 14644 cleanroom certification support)
  • Field validation of biogas or natural gas metering systems prior to fiscal installation
  • Research lab gas blending consistency checks for catalytic studies or plasma processing

FAQ

Which flow sensors are compatible with the 05629-22/40?
Only Cole-Parmer Roto-X and Metalex gas flow sensors are electrically and algorithmically compatible. Roto-X low-flow models are excluded due to insufficient pulse amplitude and out-of-spec frequency range.
Can the totalizer be reset remotely?
No—totalizer reset is local-only via front-panel keypad. The device includes both fixed and user-resettable totalizers; the latter requires physical access and password-protected menu navigation.
Is the 4–20 mA output isolated?
No—the analog output is non-isolated. For galvanic isolation, an external signal conditioner or isolated transmitter module must be installed in series.
What happens to accumulated data during battery replacement?
All totalized values and configuration parameters are retained in non-volatile memory; no data loss occurs during battery swap on the 05629-22.
Does the unit support Modbus or other digital communication protocols?
No—it provides only analog (4–20 mA), pulse, and relay outputs. Integration with Modbus networks requires an external protocol converter.