Empowering Scientific Discovery

GreenPrima PM8200I Online Fluoride Ion Analyzer

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand GreenPrima
Origin United Kingdom
Manufacturer Type Original Equipment Manufacturer (OEM)
Product Category Imported Instrument
Model PM8200I Fluoride
Instrument Type Online Analyzer
Measurement Range 0–30,000 mg/L F⁻
Detection Limits 0.01 / 0.1 / 1 ppm
Response Time ≤30 s
Accuracy ±0.01, ±0.1, or ±1 ppm (dependent on range selection)
Operating Temperature Range −5 to +70 °C
Temperature Compensation −10 to +130 °C (NTC10K or PT1000 sensor compatible)
Display Backlit graphic LCD with adjustable contrast
Data Storage 600,000 records with timestamped query capability
Output Dual isolated 4–20 mA (max. loop resistance 500 Ω, accuracy 0.1% FS)
Communication RS485 interface, MODBUS RTU protocol compliant
Relay Output 1 multifunctional relay (configurable for cleaning cycle trigger, alarm notification, or fault indication)
Enclosure Rating IP65
Power Supply 90–260 VAC, 50/60 Hz or optional 24 VDC
Mounting Options Wall-mount, pole-mount, panel-mount
Dimensions 144 × 144 × 106 mm
Panel Cutout 138 × 138 mm
Weight 0.86 kg
Fluoride Electrode Bsens710
Electrode Material Polyphenylsulfone (PPS)
Electrode Pressure Rating ≤3.5 bar
Cable Length 5 m
Electrode Measurement Range 0–20 ppm F⁻
Electrode Resolution 0.1 mg/L
Electrode Accuracy ±3% FS

Overview

The GreenPrima PM8200I Online Fluoride Ion Analyzer is a robust, field-deployable potentiometric measurement system engineered for continuous, real-time quantification of fluoride ion (F⁻) concentration in aqueous process streams and environmental water matrices. It operates on the principle of selective ion detection via a solid-state, polyphenylsulfone (PPS)-housed fluoride ion-selective electrode (ISE), coupled with a stable reference electrode and integrated temperature compensation. The instrument employs a Nernstian response curve calibrated against traceable standard solutions, enabling direct conversion of measured millivolt potential into concentration values across three selectable resolution modes (0.01, 0.1, or 1 ppm). Designed for unattended operation in municipal, industrial, and regulatory-compliant monitoring environments, the PM8200I delivers high reproducibility under variable flow, pressure, and ambient thermal conditions — critical for applications where fluoridation control, effluent compliance, or raw water quality assurance is mandated.

Key Features

  • Industrial-grade IP65-rated enclosure with full gasket sealing, suitable for outdoor installation and high-humidity or chemically aggressive atmospheres.
  • High-contrast backlit graphical LCD display with user-adjustable brightness and contrast; supports dual-language (English/Chinese) menu navigation without hardware modification.
  • Dual isolated 4–20 mA analog outputs, each independently scalable and configurable for primary fluoride reading, temperature, or diagnostic status — compliant with IEC 61000-6-2/4 EMC standards.
  • RS485 serial interface implementing MODBUS RTU protocol (slave ID 1–247), enabling seamless integration into SCADA, DCS, or PLC-based supervisory systems.
  • Configurable multifunction relay supporting programmable cleaning cycles (interval: 0.1–1000 h; duration: 1–1000 s), threshold alarms, and system fault signaling per EN 61508 SIL1 functional safety guidelines.
  • Onboard non-volatile memory storing up to 600,000 timestamped data points (F⁻ concentration, temperature, date/time, electrode potential, and system status), accessible via serial query or local display review.
  • Auto-power-saving mode: backlight deactivates after 3 minutes of no keypad interaction, extending display lifespan and reducing standby power consumption.

Sample Compatibility & Compliance

The PM8200I is validated for use with potable water, surface water, wastewater effluents, cooling tower recirculation loops, semiconductor rinse water, electroplating baths, and pharmaceutical process water. Its Bsens710 fluoride electrode exhibits minimal interference from common anions including chloride (Cl⁻), nitrate (NO₃⁻), sulfate (SO₄²⁻), and phosphate (PO₄³⁻) within typical environmental concentration ranges. The analyzer meets ISO 5667-3:2018 requirements for sampling preservation and measurement traceability when operated with certified calibration standards (e.g., NIST-traceable NaF solutions). It supports audit-ready data logging aligned with GLP and GMP principles, including time-stamped calibration records, maintenance logs, and event-triggered alerts — essential for facilities subject to EPA Method 300.0, ISO 10304-1, or WHO Guideline Limits for fluoride in drinking water (1.5 mg/L).

Software & Data Management

No proprietary PC software is required for basic configuration; all setup is performed locally via intuitive on-device menu navigation. For centralized deployment, GreenPrima provides a MODBUS register map (available upon request) facilitating custom HMI development or integration with third-party platforms such as Ignition, Siemens Desigo, or Honeywell Experion. All stored historical data retain absolute timestamps synchronized to internal RTC (real-time clock) with ±2 s/month drift. Data export is supported via MODBUS function code 03 (Read Holding Registers) using standard polling intervals. Firmware updates are delivered via secure UART interface using signed binary files — ensuring integrity verification prior to flash programming.

Applications

  • Municipal drinking water treatment plants performing fluoride dosing control and regulatory reporting (e.g., US EPA 40 CFR Part 141, EU Directive 98/83/EC).
  • Wastewater treatment facilities monitoring industrial discharge compliance with local fluorine limits (e.g., China’s GB 8978-1996, Germany’s AbwV Annex 33).
  • Semiconductor fabrication sites requiring sub-ppm fluoride monitoring in ultrapure rinse water to prevent etching of silicon dioxide layers.
  • Electroplating and metal finishing operations managing hydrofluoric acid (HF) bath chemistry and waste stream neutralization efficacy.
  • Pharmaceutical manufacturing utilities verifying fluoride levels in purified water (PW) and water-for-injection (WFI) per USP and EP 2.2.38.
  • Power plant condensate polishing systems detecting fluoride ingress from steam cycle corrosion byproducts.

FAQ

What calibration standards are recommended for daily verification?
NIST-traceable sodium fluoride (NaF) standards at 0.1, 1.0, and 10.0 ppm F⁻ are recommended for two-point calibration and one-point verification. Calibration frequency should follow site-specific QA/QC protocols — typically every 24–72 hours in continuous operation.
Can the PM8200I operate in pressurized piping systems?
Yes — the Bsens710 electrode is rated for continuous operation at pressures up to 3.5 bar (51 psi); however, a pressure-regulating bypass or flow cell with pressure relief must be installed upstream to avoid mechanical stress on the sensing membrane.
Is temperature compensation automatic or manual?
Both modes are supported: automatic compensation using integrated NTC10K or PT1000 sensors, or manual offset entry within ±10 °C of actual sample temperature.
How often does the fluoride electrode require replacement?
Under typical municipal water conditions (pH 6.5–8.5, low turbidity, no suspended solids), electrode service life exceeds 12 months. In high-fluoride or acidic industrial streams, replacement interval may reduce to 6–9 months — indicated by increased drift (>2 mV/h), sluggish response (>60 s), or failure to calibrate within tolerance.
Does the analyzer support FDA 21 CFR Part 11 compliance?
While the PM8200I itself does not provide electronic signature or audit trail encryption natively, its MODBUS-enabled data output and immutable onboard logging allow full Part 11 compliance when integrated with validated third-party data acquisition and archiving systems meeting ALCOA+ principles.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0