Hanna HI991003 Portable pH/ORP/Temperature Meter

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Hanna Instruments
Origin Italy
Model HI991003
pH Range -2.00 to 16.00
pH Resolution 0.01
pH Accuracy ±0.01
ORP Range ±1999 mV
ORP Resolution 1 mV
ORP Accuracy ±0.2 mV
Temperature Range -20.0 to 120.0°C
Temp Resolution 0.1°C
Temp Accuracy ±0.5°C (≤60°C), ±1.0°C (>60°C)
Calibration Auto-recognizing 1–2 point with dual built-in buffer sets (pH 4.01/7.01/10.01 and 4.01/6.86/9.18)
Temperature Compensation Automatic (-5.0 to 105.0°C)
Electrode HI1297D stainless steel body pH/ORP/ATC combination probe
Power 3 × 1.5 V AAA batteries
IP Rating IP67 (dust-tight, immersion up to 1 m for 30 min)
Dimensions 152 × 58 × 30 mm
Weight 205 g

Overview

The Hanna HI991003 is a rugged, portable benchtop-style pH/ORP/temperature meter engineered for high-reliability field and laboratory measurements in water quality, environmental monitoring, food processing, aquaculture, and industrial process control. It operates on the fundamental electrochemical principles of potentiometric measurement: pH is determined via the Nernst equation using a glass membrane electrode, while ORP (oxidation-reduction potential) is measured as the open-circuit voltage between a noble metal sensing element (typically platinum or gold) and a stable reference electrode—both integrated into the HI1297D combination probe. The instrument features automatic temperature compensation (ATC) using an embedded thermistor, ensuring thermally corrected pH and ORP values across the full operational range of –20.0 to 120.0°C. Its microprocessor-controlled architecture enables stable endpoint detection, real-time signal averaging, and intelligent buffer recognition—minimizing operator dependency and mitigating systematic error from manual calibration drift.

Key Features

  • Integrated HI1297D probe with stainless steel body, corrosion-resistant titanium-coated junction, and built-in ATC sensor—designed for durability in aggressive media and easy cleaning to extend service life
  • Dual pre-programmed calibration sets (pH 4.01/7.01/10.01 and 4.01/6.86/9.18) with auto-buffer recognition and 1–2 point calibration routines compliant with ISO 7888 and ASTM D1293
  • Auto-endpoint hold function with visual stability indicator—ensures consistent data capture without premature reading
  • Simultaneous dual-parameter display: pH (or mV) + °C on a large backlit LCD; intuitive icon-driven interface with two-button operation
  • BEPS (Battery Error Prevention System) monitors battery voltage in real time and disables measurement below safe operating threshold to prevent erroneous results
  • IP67-rated housing—fully dust-tight and submersible up to 1 meter for 30 minutes—validated per IEC 60529 for use in humid, outdoor, or splash-prone environments
  • Low-power design with auto-off after 20 minutes of inactivity; battery replacement requires no tools and preserves calibration memory

Sample Compatibility & Compliance

The HI991003 is validated for aqueous solutions including drinking water, wastewater effluent, nutrient solutions, brines, and mild chemical process streams. It is not intended for non-aqueous solvents, highly viscous slurries, or samples containing sulfides, heavy metals, or proteins that may foul the reference junction. The HI1297D probe’s double-junction design minimizes contamination migration and extends calibration stability in challenging matrices. Instrument firmware adheres to GLP (Good Laboratory Practice) data integrity requirements: all calibrations are timestamped and stored internally (up to 50 events), with user-accessible logs supporting traceability. While not FDA 21 CFR Part 11–certified out-of-the-box, audit-ready calibration records—including date, buffer IDs, slope (%), offset (mV), and temperature—can be manually documented for ISO/IEC 17025-accredited laboratories.

Software & Data Management

The HI991003 operates as a standalone instrument with no proprietary software dependency. All calibration, measurement, and diagnostic functions are executed onboard. Internal memory retains calibration history, last-measured values, and system diagnostics. For regulatory documentation, users export calibration metadata manually via visual inspection of the LCD log screen. No Bluetooth, USB, or cloud connectivity is included—intentionally omitting wireless interfaces to eliminate cybersecurity vulnerabilities and ensure electromagnetic compatibility in industrial settings per EN 61326-1. This architecture aligns with IEC 61000-4 immunity standards and supports long-term reliability in electrically noisy environments such as pump stations or food production lines.

Applications

  • Environmental field testing: surface water pH/ORP profiling, sediment pore-water redox assessment, and wetland restoration monitoring
  • Food & beverage QA/QC: pH verification of dairy products, meat marinades, fermented beverages, and RTE (ready-to-eat) formulations per USDA-FSIS guidelines
  • Aquaculture management: real-time tracking of pond pH diurnal shifts and ORP as an indicator of nitrification efficiency and dissolved oxygen saturation
  • Swimming pool & spa maintenance: rapid verification of sanitizer efficacy through ORP correlation with free chlorine residuals (per CDC Model Aquatic Health Code)
  • Industrial pretreatment: monitoring of acid wash tanks, neutralization basins, and electroplating bath stability

FAQ

What electrode is required for the HI991003?
The instrument is exclusively compatible with the HI1297D stainless steel combination pH/ORP/ATC probe. Substitution with third-party or non-Hanna electrodes invalidates calibration accuracy and voids warranty.
Does the HI991003 support manual temperature input?
No—temperature is measured exclusively via the integrated thermistor in the HI1297D probe. Manual entry is disabled to prevent compensation errors.
Can this meter be used for soil slurry measurements?
Only when prepared as a 1:5 (w/v) aqueous extract per ASTM D4972; direct insertion into undiluted soil is not supported due to junction clogging risk.
How often should the HI1297D electrode be cleaned and reconditioned?
Clean after each use with deionized water; soak in HI7061L electrolyte cleaning solution for 15 minutes weekly if used in protein- or sulfide-rich samples. Recalibrate before each measurement session.
Is the HI991003 suitable for GMP-regulated pharmaceutical water systems?
It meets basic performance criteria for purified water (PW) and water for injection (WFI) spot checks per USP , but lacks electronic audit trail functionality required for full GMP compliance; dedicated validated systems are recommended for routine release testing.