Empowering Scientific Discovery

Jiebi Technology (Beijing) Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKittiwake
OriginUnited Kingdom
Manufacturer TypeAuthorized Distributor
Import StatusImported
ModelFG-K
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSETA
OriginUnited Kingdom
Model99580-0
Conductivity Range0–2000 pS/m
Resolution0.1 pS/m and 0.1 °C
Temperature Accuracy±0.5 °C
Operating Temperature−30 °C to +50 °C
Power SourceReplaceable AAA batteries
ComplianceASTM D2624, IP 274, GB/T 6539
Measurement PrincipleAC Conductance (2-electrode, frequency-compensated)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandParker
OriginUnited Kingdom
ModelLCM20
Calibration StandardsACFTD & MTD
Channel Count6
Detection PrincipleSingle-Point Source Laser (SPSL) Light Scattering
DisplayIntegrated LCD Handheld Unit
Data Storage300 Test Records
Pressure RatingUp to 420 bar
Flow CompatibilityUp to 400 L/min (with system integration)
CommunicationRS232 @ 9600 baud
ComplianceISO 4406, ISO 11171, NAS 1638, ASTM D6786
SoftwareDAT μm Trend Analysis Suite (free firmware updates included)
Optional AccessoriesBarcode Scanner, Built-in Thermal Printer, Relay Output for External Equipment Control
ServiceAnnual calibration support via Parker Authorized Service Centers
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSETA
OriginUnited Kingdom
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelSA6000-0
Measurement ParameterDiesel Cetane Number (CN)
Form FactorBenchtop
Detection PrincipleConstant-Volume Combustion Method
Standards ComplianceIP 617, prEN 17155, ASTM D8183, EN 590 Clause 5.7.4, ASTM D613, EN ISO 5165, DIN 51773
Calibration Fuelsn-Hexadecane and 2,2,4,4,6,8,8-Heptamethylnonane (HMN)
Sample Volume per Test40 mL
Test Duration per Sample~25 min
Autosampler Capacity36 positions
Fuel Injection SystemPiezoelectric High-Pressure Injector with Temperature-Controlled Nozzle
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSETA
OriginUnited Kingdom
ModelSA1900-0
Instrument TypeOptical Particle Counter
Compliance StandardsIP 565, NB/SH/T 0868, ASTM D7647, ISO 4406, ISO 60970, ASTM D6786, NAS 1638, AS 4059F, ISO 11171, ISO 11500, SAE J183, SAE J749D, GOST 17216, GB/T 5930, GJB 420A–1996, GJB 420B–2006, JIS B 9932:2012, JIS B 9933:2021, JIS B 9934:2012
Sample Viscosity RangeUp to 400 cSt (tested with in-service lubricants, hydraulic fluids, and insulating oils)
Sealing MaterialFFKM (perfluoroelastomer)
Integrated Pressure PumpYes
Analysis Time≤ 3 minutes per sample
Control ModesStandalone operation or PC-controlled via ProTrend software
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSETA
OriginUnited Kingdom
Model22100-0
Maximum Operating Pressure1400 kPa (200 psi)
Temperature Range−20 °C to +60 °C
Test Chamber Burst Pressure2800 kPa
ComplianceASTM D1657, BS EN ISO 3993, IP 235, SH/T 0221
Added to wishlistRemoved from wishlist 0
Add to compare
BrandORBIS BV
OriginNetherlands
Manufacturer TypeAuthorized Distributor
Origin CategoryImported Instrument
ModelCFPP
Price RangeUSD 13,500 – 67,500 (FOB Rotterdam)
Test Range−105 °C to +65 °C
Temperature Accuracy±0.1 °C
Temperature SensorPT100 Class A
Temperature Resolution0.1 °C
Vacuum ControlMicroprocessor-controlled, programmable fixed/dynamic vacuum (2.0 ± 0.1 kPa)
Cooling SystemIntegrated solid-state thermoelectric bath (no external chiller required), min. temp. −105 °C
Cooling ProfileProgrammable linear and stepwise ramping
Sample DetectionTriple-point laser level sensor
Filtration Mesh45 µm stainless steel
Pipette Volume20 mL
Timing Resolution>0.1 s (digital display)
Data Storage Capacity200 test records
Cleaning ProtocolFully automated dual-solvent wash cycle
Power Supply100–240 VAC, 50/60 Hz
Power Consumption150 W
Dimensions (W×D×H)16 cm × 59 cm × 35 cm
Weight25 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandORBIS BV
OriginNetherlands
Manufacturer TypeAuthorized Distributor
Origin CategoryImported Instrument
ModelSTARDist
Operating PressureAtmospheric
Temperature RangeAmbient to 450 °C
Temperature Accuracy±0.1 °C
Condenser Temperature Range0–65 °C
Recovery Chamber Temperature Range0–45 °C
Distillation Rate2–11 mL/min
Volume Detection Range0–105% (v/v)
Volume Resolution0.01 mL
Volume Accuracy±0.01 mL
Residue MeasurementAutomatic or Manual
Barometric Range70–110 kPa (0.1 kPa resolution)
Safety SystemIntegrated Flame Detection with Nitrogen-Actuated Extinguishing
Data InterfaceEthernet (LIMS-compatible)
Dimensions40 × 40 × 63 cm
Weight40 kg
Power Supply100–240 VAC, 50/60 Hz
Power Consumption1.2 kW
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSETA
OriginItaly
Model22423
Ultimate Vacuum1×10⁻² mbar
Air Flow Rate46 L/min (standard) / 66 L/min (high-flow variant)
Dimensions270 × 150 × 250 mm
Weight7 kg
Inlet Port Sizes1/4″, 5/16″, and 3/8″ NPT/Female
Oil Mist FilterIntegrated
TypeRotary Vane, Oil-Lubricated Vacuum Pump
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKittiwake
OriginUnited Kingdom
Manufacturer TypeAuthorized Distributor
Origin CategoryImported Instrument
ModelWDS Series (Custom Configuration Available)
PriceContact for Quotation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTTZH
OriginGermany
ModelRST-T200-P4
Temperature RangeAmbient to 200 °C (±0.5 °C)
Rotational Speed165 rpm (adjustable 100–200 rpm)
Roller Mass5 kg ± 50 g
Dimensions700 × 730 × 690 mm
Weight70 kg
ComplianceASTM D1831, SH/T 0122
Interface OptionRS485
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSETA
OriginUnited Kingdom
Model80000-0
Temperature Range−25 °C to 100 °C (below ambient up to 100 °C)
Temperature Resolution0.1 °C
Pressure Range0–700 kPa
Pressure Resolution0.1 kPa
Pressure UnitskPa, psi, kg/cm², mbar, mmHg, inHg (user-selectable)
Test Chamber Volume15 mL ±1%
Required Vacuum Level< 0.01 kPa
InterfaceRS232C
Power Supply110/120 V or 220/240 V, 50/60 Hz (switchable)
Power Consumption200 W
Dimensions35 × 45 × 37 cm
Weight22.8 kg
ComplianceASTM D5188, D5191, D323, D2533, D4953, D5482, D6378
Added to wishlistRemoved from wishlist 0
Add to compare
KeyBrand: SETA
OriginUnited Kingdom
Model12200-3
Temperature Range140–260 °C (±5 °C)
Heating Power2 × 1 kW
Over-Temperature Cut-OffAdjustable at 280 °C
Dimensions45 × 35 × 50 cm
Weight45 kg
Test Positions5
Evaporation MediumCompressed Air or Steam
Integrated Steam GeneratorYes
Control TypeDigital Temperature Controller
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOptimol
OriginGermany
ModelSRV®5
Instrument TypeReciprocating Tribometer
Maximum Friction Force2500 N
Friction Force Resolution1 N
Operating Temperature Range−35 °C to 1000 °C
Motion ModesReciprocating, Rotational, Tilted (0°–90°), Oscillatory, Non-Continuous Transition
Optional ModulesFSA (Friction Signal Analysis), Vacuum Chamber (High Vacuum), Nanopositioning Stage, Electrical Resistance Monitoring, Custom Fixture Integration
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRigaku
OriginJapan
ModelDSCvesta2
Temperature Range–180 to 725 °C (atmospheric: RT to 600 °C
mechanical cooling–95 to 725 °C)
Heating/Cooling Rateup to 100 °C/min
Gas Flow Range0–250 mL/min (resolution: 1 mL/min)
Heat Flow Range±1000 mW
Noise Level< 0.05 µW
Baseline Repeatability (–70 to 300 °C)≤ 10 µW
Enthalpy Sensitivity0.1 µW
Sensor TypeHeat-Flow-Type Metallic Sensor with vestaeye® Self-Diagnostic Function
Furnace MaterialPure Silver or Pure Platinum
Calibration Standards≥5 Certified Reference Materials (including Indium, Zinc, Tin, Bismuth, Lead)
Software FeaturesDual-data logging (raw + corrected), LIMS integration support, export to Word, Excel, JPG, PDF
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRigaku
OriginJapan
ModelTG-DTA8122
Temperature RangeAmbient to 1100 °C (standard), up to 1500 °C (high-temperature option)
Heating RateUp to 100 °C/min
Balance SystemHorizontal differential triple-coil design
Max. Sample Mass1 g
TG Full Scale±250 mg (500 mg FS)
TG Sensitivity0.01 µg
DTA Full Scale±1000 µV (2000 µV FS)
Atmosphere OptionsAir, inert gas, vacuum, steam, controlled flow
Optional Autosampler24 sample positions + 3 reference + 5 calibration positions
Standard Operating ModesConstant Reaction Control (CRC), Step Isothermal Analysis (SIA), Dynamic Rate Control (DRC)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSETA
OriginUnited Kingdom
ModelSA1100-0
Instrument TypeOptical Particle Counter
Particle Size Range (ISO 11171)4 µm to >70 µm
Particle Size Range (ISO 4402)2 µm to >100 µm
Number of Sizing Channels16
Maximum Particle Count per Test60,000 particles/mL
Sample Viscosity Rangeup to 68 mm²/s (direct from bottle), up to 500 mm²/s at 10 bar
Sample Temperature Range0–70 °C
Flow Rate30 mL/min
Total Sample Volume per Test80 mL (including rinse) for IP 565
Maximum Inlet Pressure10 bar (310 bar optional)
Output Unitsparticles/mL or particles/10 mL
Cleanliness CodesCumulative & Differential per ISO 4406, NAS 1638, SAE AS4059, JIS B 9932:2012, JIS B 9933:2021, JIS B 9934:2012, GOST 17216, Defence Standards 91-091 & 91-86, ASTM D975, D6299, D7619, D7647, IP 565, IP 630
Calibration StandardISO 11171
Data InterfacesEthernet, USB
DisplayIntegrated touchscreen interface
Onboard SQC SoftwareCompliant with ASTM D6299 statistical quality control requirements
User AuthenticationPassword-protected access levels
Embedded Test Methods14 preconfigured methods
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSETA
OriginUnited Kingdom
Model91600-3
ComplianceASTM D2068, IP 387 (Procedures A, B & C), ASTM D6426 (Cold Soak), IP PM EA/08
Filtration Plug Trend Range1.0–30
Filterability Quality Factor Range100–1
Maximum Test Pressure200 kPa
Power Consumption500 W
Dimensions27 × 43 × 26 cm
Weight10 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSETA
OriginUnited Kingdom
Model11400-6
Bath Volume35 L
Test Positions9
Temperature RangeAmbient to 150 °C
Bath MediumOil or Water
ComplianceASTM D130, IP 154, ISO 2160, EN 2160, GB/T 5096, SH/T 0023, DIN 51811, JIS K2513, NF M07-015, FTMS 791B 5325
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSETA
OriginUnited Kingdom
Model94710-4
Temperature Range-40 °C to +20 °C
Temperature Stability±0.01 °C
Test Positions2
Bath Volume7 L (oil)
Cooling SystemIntegrated refrigeration (reaches -40 °C in <4 h)
Safety FeaturesIndependent overtemperature and low-fluid-level cut-off
Viewing Window & Insulated Top PlatePrevents condensation
ComplianceASTM D445, ASTM D446, IP 71, BS 188, BS 2000-71-2, ISO 3105, BS EN ISO 3104, BS 2000-71.1, GB/T 265
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKittiwake
OriginUnited Kingdom
ModelFG-K16000-KW
Measurement Range0–2000 PQ
Display Accuracy±5 PQ
Repeatability±15 PQ or ±3% of mean (whichever is greater)
Operating Temperature15–35 °C
Power Supply110–250 VAC, auto-switching 50/60 Hz
Warm-up Time<5 min
Test Time per Sample≤15 s
Sample VesselStandard 100 mL bottle or 2 mL vial
Weight1.4 kg
Safety Rating2.5 A, 250 VAC, HRC A/S T ceramic fuse
Lid DetectionOptical reflection sensor
Sample DetectionOptical reflection sensor
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSETA
OriginUnited Kingdom
Model22210-3
Temperature Range5°C to 90°C (ambient referenced)
Temperature Uniformity±0.1°C at 37.8°C
Bath Volume80 L
CapacityUp to six RVP test bombs
Power Supply220/240 V, 50/60 Hz
Power Consumption2.2 kW
Dimensions (W × D × H)77 × 55 × 51 cm
Weight70 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOptimol
OriginGermany
Model2Disk
Drive Speed Range1–3000 rpm
Applied Load Range10–5000 N
Maximum Test Duration999 h
CoolingOptional Water-Cooled Drive Spindle
Temperature MonitoringIntegrated Spindle & Lubricant Temperature Sensors
Optional MeasurementsLubricant Film Thickness (Oil Gap), Electrical Resistance, Acoustic Emission (Noise), Wear Volume Quantification
Environmental Control OptionsHeated Oil Bath, External Oil Circulation Pump
SoftwareCustomizable LabVIEW- or Python-Based Control & Data Acquisition Suite
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLovibond/Tintometer
OriginUnited Kingdom
ModelET4110
Measurement UnitPfund scale (0–160 Pfund)
ComplianceUSDA Honey Grading Standards (7 Grade Classes), ASTM D1544 (for color reference correlation)
DisplayDigital LCD with keypad interface
Application ModeBenchtop & Field-Portable Operation
Power SupplyAC adapter or battery-powered (4 × AA, optional)
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0