- All
- Favorite
- Popular
- Most rated
| Brand | Kittiwake |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | FG-K |
| Pricing | Available Upon Request |
| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | 99580-0 |
| Conductivity Range | 0–2000 pS/m |
| Resolution | 0.1 pS/m and 0.1 °C |
| Temperature Accuracy | ±0.5 °C |
| Operating Temperature | −30 °C to +50 °C |
| Power Source | Replaceable AAA batteries |
| Compliance | ASTM D2624, IP 274, GB/T 6539 |
| Measurement Principle | AC Conductance (2-electrode, frequency-compensated) |
| Brand | Parker |
|---|---|
| Origin | United Kingdom |
| Model | LCM20 |
| Calibration Standards | ACFTD & MTD |
| Channel Count | 6 |
| Detection Principle | Single-Point Source Laser (SPSL) Light Scattering |
| Display | Integrated LCD Handheld Unit |
| Data Storage | 300 Test Records |
| Pressure Rating | Up to 420 bar |
| Flow Compatibility | Up to 400 L/min (with system integration) |
| Communication | RS232 @ 9600 baud |
| Compliance | ISO 4406, ISO 11171, NAS 1638, ASTM D6786 |
| Software | DAT μm Trend Analysis Suite (free firmware updates included) |
| Optional Accessories | Barcode Scanner, Built-in Thermal Printer, Relay Output for External Equipment Control |
| Service | Annual calibration support via Parker Authorized Service Centers |
| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SA6000-0 |
| Measurement Parameter | Diesel Cetane Number (CN) |
| Form Factor | Benchtop |
| Detection Principle | Constant-Volume Combustion Method |
| Standards Compliance | IP 617, prEN 17155, ASTM D8183, EN 590 Clause 5.7.4, ASTM D613, EN ISO 5165, DIN 51773 |
| Calibration Fuels | n-Hexadecane and 2,2,4,4,6,8,8-Heptamethylnonane (HMN) |
| Sample Volume per Test | 40 mL |
| Test Duration per Sample | ~25 min |
| Autosampler Capacity | 36 positions |
| Fuel Injection System | Piezoelectric High-Pressure Injector with Temperature-Controlled Nozzle |
| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | SA1900-0 |
| Instrument Type | Optical Particle Counter |
| Compliance Standards | IP 565, NB/SH/T 0868, ASTM D7647, ISO 4406, ISO 60970, ASTM D6786, NAS 1638, AS 4059F, ISO 11171, ISO 11500, SAE J183, SAE J749D, GOST 17216, GB/T 5930, GJB 420A–1996, GJB 420B–2006, JIS B 9932:2012, JIS B 9933:2021, JIS B 9934:2012 |
| Sample Viscosity Range | Up to 400 cSt (tested with in-service lubricants, hydraulic fluids, and insulating oils) |
| Sealing Material | FFKM (perfluoroelastomer) |
| Integrated Pressure Pump | Yes |
| Analysis Time | ≤ 3 minutes per sample |
| Control Modes | Standalone operation or PC-controlled via ProTrend software |
| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | 22100-0 |
| Maximum Operating Pressure | 1400 kPa (200 psi) |
| Temperature Range | −20 °C to +60 °C |
| Test Chamber Burst Pressure | 2800 kPa |
| Compliance | ASTM D1657, BS EN ISO 3993, IP 235, SH/T 0221 |
| Brand | ORBIS BV |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | CFPP |
| Price Range | USD 13,500 – 67,500 (FOB Rotterdam) |
| Test Range | −105 °C to +65 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Sensor | PT100 Class A |
| Temperature Resolution | 0.1 °C |
| Vacuum Control | Microprocessor-controlled, programmable fixed/dynamic vacuum (2.0 ± 0.1 kPa) |
| Cooling System | Integrated solid-state thermoelectric bath (no external chiller required), min. temp. −105 °C |
| Cooling Profile | Programmable linear and stepwise ramping |
| Sample Detection | Triple-point laser level sensor |
| Filtration Mesh | 45 µm stainless steel |
| Pipette Volume | 20 mL |
| Timing Resolution | >0.1 s (digital display) |
| Data Storage Capacity | 200 test records |
| Cleaning Protocol | Fully automated dual-solvent wash cycle |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Power Consumption | 150 W |
| Dimensions (W×D×H) | 16 cm × 59 cm × 35 cm |
| Weight | 25 kg |
| Brand | ORBIS BV |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | STARDist |
| Operating Pressure | Atmospheric |
| Temperature Range | Ambient to 450 °C |
| Temperature Accuracy | ±0.1 °C |
| Condenser Temperature Range | 0–65 °C |
| Recovery Chamber Temperature Range | 0–45 °C |
| Distillation Rate | 2–11 mL/min |
| Volume Detection Range | 0–105% (v/v) |
| Volume Resolution | 0.01 mL |
| Volume Accuracy | ±0.01 mL |
| Residue Measurement | Automatic or Manual |
| Barometric Range | 70–110 kPa (0.1 kPa resolution) |
| Safety System | Integrated Flame Detection with Nitrogen-Actuated Extinguishing |
| Data Interface | Ethernet (LIMS-compatible) |
| Dimensions | 40 × 40 × 63 cm |
| Weight | 40 kg |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Power Consumption | 1.2 kW |
| Brand | SETA |
|---|---|
| Origin | Italy |
| Model | 22423 |
| Ultimate Vacuum | 1×10⁻² mbar |
| Air Flow Rate | 46 L/min (standard) / 66 L/min (high-flow variant) |
| Dimensions | 270 × 150 × 250 mm |
| Weight | 7 kg |
| Inlet Port Sizes | 1/4″, 5/16″, and 3/8″ NPT/Female |
| Oil Mist Filter | Integrated |
| Type | Rotary Vane, Oil-Lubricated Vacuum Pump |
| Brand | Kittiwake |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | WDS Series (Custom Configuration Available) |
| Price | Contact for Quotation |
| Brand | TTZH |
|---|---|
| Origin | Germany |
| Model | RST-T200-P4 |
| Temperature Range | Ambient to 200 °C (±0.5 °C) |
| Rotational Speed | 165 rpm (adjustable 100–200 rpm) |
| Roller Mass | 5 kg ± 50 g |
| Dimensions | 700 × 730 × 690 mm |
| Weight | 70 kg |
| Compliance | ASTM D1831, SH/T 0122 |
| Interface Option | RS485 |
| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | 80000-0 |
| Temperature Range | −25 °C to 100 °C (below ambient up to 100 °C) |
| Temperature Resolution | 0.1 °C |
| Pressure Range | 0–700 kPa |
| Pressure Resolution | 0.1 kPa |
| Pressure Units | kPa, psi, kg/cm², mbar, mmHg, inHg (user-selectable) |
| Test Chamber Volume | 15 mL ±1% |
| Required Vacuum Level | < 0.01 kPa |
| Interface | RS232C |
| Power Supply | 110/120 V or 220/240 V, 50/60 Hz (switchable) |
| Power Consumption | 200 W |
| Dimensions | 35 × 45 × 37 cm |
| Weight | 22.8 kg |
| Compliance | ASTM D5188, D5191, D323, D2533, D4953, D5482, D6378 |
| Key | Brand: SETA |
|---|---|
| Origin | United Kingdom |
| Model | 12200-3 |
| Temperature Range | 140–260 °C (±5 °C) |
| Heating Power | 2 × 1 kW |
| Over-Temperature Cut-Off | Adjustable at 280 °C |
| Dimensions | 45 × 35 × 50 cm |
| Weight | 45 kg |
| Test Positions | 5 |
| Evaporation Medium | Compressed Air or Steam |
| Integrated Steam Generator | Yes |
| Control Type | Digital Temperature Controller |
| Brand | Optimol |
|---|---|
| Origin | Germany |
| Model | SRV®5 |
| Instrument Type | Reciprocating Tribometer |
| Maximum Friction Force | 2500 N |
| Friction Force Resolution | 1 N |
| Operating Temperature Range | −35 °C to 1000 °C |
| Motion Modes | Reciprocating, Rotational, Tilted (0°–90°), Oscillatory, Non-Continuous Transition |
| Optional Modules | FSA (Friction Signal Analysis), Vacuum Chamber (High Vacuum), Nanopositioning Stage, Electrical Resistance Monitoring, Custom Fixture Integration |
| Brand | Rigaku |
|---|---|
| Origin | Japan |
| Model | DSCvesta2 |
| Temperature Range | –180 to 725 °C (atmospheric: RT to 600 °C |
| mechanical cooling | –95 to 725 °C) |
| Heating/Cooling Rate | up to 100 °C/min |
| Gas Flow Range | 0–250 mL/min (resolution: 1 mL/min) |
| Heat Flow Range | ±1000 mW |
| Noise Level | < 0.05 µW |
| Baseline Repeatability (–70 to 300 °C) | ≤ 10 µW |
| Enthalpy Sensitivity | 0.1 µW |
| Sensor Type | Heat-Flow-Type Metallic Sensor with vestaeye® Self-Diagnostic Function |
| Furnace Material | Pure Silver or Pure Platinum |
| Calibration Standards | ≥5 Certified Reference Materials (including Indium, Zinc, Tin, Bismuth, Lead) |
| Software Features | Dual-data logging (raw + corrected), LIMS integration support, export to Word, Excel, JPG, PDF |
| Brand | Rigaku |
|---|---|
| Origin | Japan |
| Model | TG-DTA8122 |
| Temperature Range | Ambient to 1100 °C (standard), up to 1500 °C (high-temperature option) |
| Heating Rate | Up to 100 °C/min |
| Balance System | Horizontal differential triple-coil design |
| Max. Sample Mass | 1 g |
| TG Full Scale | ±250 mg (500 mg FS) |
| TG Sensitivity | 0.01 µg |
| DTA Full Scale | ±1000 µV (2000 µV FS) |
| Atmosphere Options | Air, inert gas, vacuum, steam, controlled flow |
| Optional Autosampler | 24 sample positions + 3 reference + 5 calibration positions |
| Standard Operating Modes | Constant Reaction Control (CRC), Step Isothermal Analysis (SIA), Dynamic Rate Control (DRC) |
| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | SA1100-0 |
| Instrument Type | Optical Particle Counter |
| Particle Size Range (ISO 11171) | 4 µm to >70 µm |
| Particle Size Range (ISO 4402) | 2 µm to >100 µm |
| Number of Sizing Channels | 16 |
| Maximum Particle Count per Test | 60,000 particles/mL |
| Sample Viscosity Range | up to 68 mm²/s (direct from bottle), up to 500 mm²/s at 10 bar |
| Sample Temperature Range | 0–70 °C |
| Flow Rate | 30 mL/min |
| Total Sample Volume per Test | 80 mL (including rinse) for IP 565 |
| Maximum Inlet Pressure | 10 bar (310 bar optional) |
| Output Units | particles/mL or particles/10 mL |
| Cleanliness Codes | Cumulative & Differential per ISO 4406, NAS 1638, SAE AS4059, JIS B 9932:2012, JIS B 9933:2021, JIS B 9934:2012, GOST 17216, Defence Standards 91-091 & 91-86, ASTM D975, D6299, D7619, D7647, IP 565, IP 630 |
| Calibration Standard | ISO 11171 |
| Data Interfaces | Ethernet, USB |
| Display | Integrated touchscreen interface |
| Onboard SQC Software | Compliant with ASTM D6299 statistical quality control requirements |
| User Authentication | Password-protected access levels |
| Embedded Test Methods | 14 preconfigured methods |
| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | 91600-3 |
| Compliance | ASTM D2068, IP 387 (Procedures A, B & C), ASTM D6426 (Cold Soak), IP PM EA/08 |
| Filtration Plug Trend Range | 1.0–30 |
| Filterability Quality Factor Range | 100–1 |
| Maximum Test Pressure | 200 kPa |
| Power Consumption | 500 W |
| Dimensions | 27 × 43 × 26 cm |
| Weight | 10 kg |
| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | 11400-6 |
| Bath Volume | 35 L |
| Test Positions | 9 |
| Temperature Range | Ambient to 150 °C |
| Bath Medium | Oil or Water |
| Compliance | ASTM D130, IP 154, ISO 2160, EN 2160, GB/T 5096, SH/T 0023, DIN 51811, JIS K2513, NF M07-015, FTMS 791B 5325 |
| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | 94710-4 |
| Temperature Range | -40 °C to +20 °C |
| Temperature Stability | ±0.01 °C |
| Test Positions | 2 |
| Bath Volume | 7 L (oil) |
| Cooling System | Integrated refrigeration (reaches -40 °C in <4 h) |
| Safety Features | Independent overtemperature and low-fluid-level cut-off |
| Viewing Window & Insulated Top Plate | Prevents condensation |
| Compliance | ASTM D445, ASTM D446, IP 71, BS 188, BS 2000-71-2, ISO 3105, BS EN ISO 3104, BS 2000-71.1, GB/T 265 |
| Brand | Kittiwake |
|---|---|
| Origin | United Kingdom |
| Model | FG-K16000-KW |
| Measurement Range | 0–2000 PQ |
| Display Accuracy | ±5 PQ |
| Repeatability | ±15 PQ or ±3% of mean (whichever is greater) |
| Operating Temperature | 15–35 °C |
| Power Supply | 110–250 VAC, auto-switching 50/60 Hz |
| Warm-up Time | <5 min |
| Test Time per Sample | ≤15 s |
| Sample Vessel | Standard 100 mL bottle or 2 mL vial |
| Weight | 1.4 kg |
| Safety Rating | 2.5 A, 250 VAC, HRC A/S T ceramic fuse |
| Lid Detection | Optical reflection sensor |
| Sample Detection | Optical reflection sensor |
| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | 22210-3 |
| Temperature Range | 5°C to 90°C (ambient referenced) |
| Temperature Uniformity | ±0.1°C at 37.8°C |
| Bath Volume | 80 L |
| Capacity | Up to six RVP test bombs |
| Power Supply | 220/240 V, 50/60 Hz |
| Power Consumption | 2.2 kW |
| Dimensions (W × D × H) | 77 × 55 × 51 cm |
| Weight | 70 kg |
| Brand | Optimol |
|---|---|
| Origin | Germany |
| Model | 2Disk |
| Drive Speed Range | 1–3000 rpm |
| Applied Load Range | 10–5000 N |
| Maximum Test Duration | 999 h |
| Cooling | Optional Water-Cooled Drive Spindle |
| Temperature Monitoring | Integrated Spindle & Lubricant Temperature Sensors |
| Optional Measurements | Lubricant Film Thickness (Oil Gap), Electrical Resistance, Acoustic Emission (Noise), Wear Volume Quantification |
| Environmental Control Options | Heated Oil Bath, External Oil Circulation Pump |
| Software | Customizable LabVIEW- or Python-Based Control & Data Acquisition Suite |
| Brand | Lovibond/Tintometer |
|---|---|
| Origin | United Kingdom |
| Model | ET4110 |
| Measurement Unit | Pfund scale (0–160 Pfund) |
| Compliance | USDA Honey Grading Standards (7 Grade Classes), ASTM D1544 (for color reference correlation) |
| Display | Digital LCD with keypad interface |
| Application Mode | Benchtop & Field-Portable Operation |
| Power Supply | AC adapter or battery-powered (4 × AA, optional) |