Empowering Scientific Discovery

Beijing United Scientific Instrument Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJingHong
OriginShanghai, China
ModelSXL-1008
TypeBox-Type Muffle Furnace
Max Temperature1000 °C
Temperature Control Accuracy±3 °C
Rated Power4000 W
Heating Rate300–1000 °C (typical ramp)
Heating MethodResistance Wire Heating
Internal Chamber Dimensions200 × 300 × 120 mm (W × D × H)
Temperature Range300–1000 °C
Controller30-Stage Programmable Digital PID Controller
Safety InterlockAutomatic Power Cut-off on Door Opening/Closing
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSuJing Antai
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelSW-CJ-2FD
Instrument CategoryVertical Laminar Flow Clean Bench
Cleanliness ClassISO Class 5 (equivalent to Fed. Std. 209E Class 100)
Noise Level≤62 dB(A)
User CapacityDual-operator, single-face configuration
Airflow PatternVertical downward laminar flow
Average Air Velocity0.3–0.6 m/s (adjustable)
Vibration (Half-Peak)≤5 µm
Illuminance≥300 lx
Power SupplyAC 220 V, 50 Hz, Single-phase
Max. Power Consumption0.8 kW
Net Weight350 kg
Work Area Dimensions (W×D×H)1360 × 700 × 520 mm
Overall Dimensions (W×D×H)1480 × 720 × 1600 mm
Microbial Count≤0.5 CFU/plate·hour (90 mm Petri dish)
Work Surface MaterialImported stainless steel (AISI 304)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSoopTop
OriginShanghai, China
ModelAE124C
TypeAnalytical Balance
Maximum Capacity120 g
Readability0.0001 g
Repeatability (Standard Deviation)0.0001 g
CalibrationInternal
Pan DiameterØ90 mm
Dimensions (W×D×H)365 × 223 × 338 mm
Net Weight5.5 kg
Windshield Effective Volume160 × 165 × 200 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKedao
OriginShanghai, China
ModelSK-HP Series
Instrument TypeGeneral-Purpose Ultrasonic Cleaner
Tank Capacity3–22.5 L
Ultrasonic Frequency53 kHz
Ultrasonic Power Output100–500 W
Power Adjustment Range40–100% (1% incremental steps)
Timer Range1–999 min
Lid with Sound-Dampening DesignYes
Drain ValveAvailable on select models
Heating FunctionNot equipped
Temperature DisplayReal-time ambient tank temperature (non-heating mode)
DisplayBacklit LCD with menu-driven interface
Tank MaterialAISI 304 stainless steel
Power Failure MemoryYes
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDLAB
OriginBeijing, China
ModelD3024R
Instrument TypeBenchtop Centrifuge
Speed Range200–15,000 rpm (adjustable in 10 rpm increments)
Max RCF21,380 ×g (adjustable in 10 ×g increments)
Temperature Range−20 °C to +40 °C
Max Capacity2 mL × 24
RefrigerantEco-friendly non-CFC
Drive MotorBrushless DC motor
Dimensions (L×D×H)338 × 580 × 324 mm
Weight30 kg
SafetyDual interlocked lid, overspeed protection, overtemperature cutoff, real-time diagnostics
Power InputAC 220–240 V, 50/60 Hz, 10 A or AC 100–120 V, 50/60 Hz, 10 A
Timer30 s to 99 min or HOLD mode
Additional Functionsrpm/×g conversion, quick-spin (short-time run), progress bar display, audible end-of-run signal
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeici
OriginShanghai, China
ModelJPB-607A
Instrument TypePortable
Measurement PrincipleElectrochemical (Clark-type Polarographic Probe)
Measurement RangeDissolved Oxygen: (0.0–20.0) mg/L
Temperature(0.0–40.0) °C
Accuracy±0.30 mg/L (DO), ±0.5 °C (Temperature)
Repeatability±0.1 mg/L
Stability±0.10 mg/L over 3 h
Response Time≤45 s to 90% of final value at 20 °C
Zero Oxygen Error≤0.10 mg/L
Power SupplyTwo AA alkaline batteries
Display3.5-digit LCD with optional blue backlight
CalibrationZero-oxygen and saturated-air (full-scale) calibration supported
Temperature CompensationAutomatic, integrated thermistor
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSOPTOP
OriginShanghai, China
ModelNDJ-1
Instrument TypeAnalog Rotational Viscometer
Viscosity Range1–100,000 mPa·s
Rotational Speeds6 / 12 / 30 / 60 rpm
Spindle SetLV Spindles #1–#4
Accuracy (Newtonian Fluids)±5%
Dimensions (W×D×H)275 × 265 × 445 mm
DisplayAnalog Pointer Gauge
Speed ControlManual Gear Shift
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSartorius
OriginShanghai, China
ModelBCE2202-1CCN
TypePrecision Balance
Maximum Capacity2200 g
Readability10 mg
Repeatability≤ ±10 mg
CalibrationExternal
Pan SizeRectangular
ConnectivityUSB-C + RS232 (9-pin)
ComplianceGLP/GMP-compliant data output
Operating Languages8 (English, German, French, Italian, Spanish, Portuguese, Russian, Polish)
Environmental ProtectionPBT housing, stainless steel & coated glass draft shield
Features@start self-test, isoCAL auto-adjustment (time- and temperature-triggered), anti-static design, overload protection, large weighing chamber with removable sliding doors
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMETTLER TOLEDO
OriginShanghai, China
ModelME203E
Instrument TypePrecision Balance
Maximum Capacity220 g
Readability0.001 g
Repeatability0.001 g
Linearity±0.002 g
Calibration MethodExternal (using certified weights)
Pan Size120 mm diameter
Draft Shield Height170 mm
Dimensions (W×D×H)210 × 319 × 289 mm
Power SupplyAC adapter (included)
Added to wishlistRemoved from wishlist 0
Add to compare
KeyBrand: Sartorius
OriginShanghai, China
ModelBCA2202i-1OCN
TypePrecision Balance
Max Capacity2200 g
Readability10 mg
Repeatability≤ ±10 mg
CalibrationInternal (isoCAL)
Pan SizeRectangular
ComplianceGLP/GMP-compliant data output, CalAuditTrail, ISO/IEC 17025-supportive operation
ConnectivityDual USB-C, RS-232 (9-pin), optional printer/U-disk interface
DisplayGraphical touchscreen with LED backlight
Languages13 built-in (including English, German, French, Spanish, Chinese, Japanese, Korean, etc.)
User ManagementUp to 10 user profiles with multi-level password protection
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKedao
OriginShanghai, China
ModelSK-HP Series (Heating Type)
Ultrasonic Frequency53 kHz
Ultrasonic Power Range100–500 W
Power Adjustment40–100% in 1% increments
Heating Temperature Range20–60 °C
Timer Range1–199 min
Tank Material304 Stainless Steel
Tank Capacity3–22.5 L
Drain ValveIncluded on select models
Sound-Dampening LidStandard
Dry-Run ProtectionYes (auto-shutoff with temperature-based no-water detection)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDLAB
OriginBeijing, China
ModelSK-O330-Pro
Oscillation ModeOrbital
Orbit Diameter (Amplitude)10 mm
Speed Range100–500 rpm
Timer Range1–1199 min
Platform Quantity1
Max Load Capacity (with clamp)7.5 kg
DisplayLCD
Motor TypeBrushless DC
Input/Output Power28 W / 15 W
Protection RatingIP21
InterfaceRS232
Temperature RangeAmbient Only
Clamp CompatibilityUniversal (interchangeable)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSOPTOP
OriginShanghai, China
Model752
Optical SystemSingle-beam
DetectorPhotomultiplier Tube (PMT)
Wavelength Range200–1000 nm
Spectral Bandwidth4 nm
Wavelength Accuracy±2.0 nm
Wavelength Repeatability1 nm
Stray Light≤0.5% T (at 220 nm and 360 nm)
Transmittance Accuracy±0.5% T
Transmittance Repeatability±0.2% T
Baseline Drift±0.003 A/h
Display128×64 LCD
Dimensions455 × 430 × 220 mm
Data InterfaceUSB
Wavelength SettingManual (keyboard-input with 6 preset wavelengths)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMETTLER TOLEDO
OriginShanghai, China
ModelLE3002E
TypePrecision Balance
Max Capacity3200.0 g
Readability0.01 g
Repeatability0.01 g
CalibrationExternal
Pan Size180.0 mm
Power SupplyAC
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginAustria
ModelSnap 41
Instrument TypePortable Digital Alcohol Meter
Measurement PrincipleU-tube Oscillation Density Method
Density Range (for Ethanol-Water Solutions)0–100 % v/v alcohol
Temperature Range (Measurement)5–30 °C (41–86 °F) with Automatic Temperature Compensation
Accuracy±0.2 % v/v alcohol, ±0.2 °C temperature
Repeatability (Std. Dev.)±0.1 % v/v alcohol, ±0.1 °C
Resolution0.01 % v/v alcohol, 0.1 °C
Sample Volume2 mL
Operating Ambient Temperature0–35 °C (32–95 °F)
DisplayDigital LCD
Environmental RatingIP54
Power Supply3 × 1.5 V LR06 (AA) alkaline batteries
Dimensions245 × 103 × 126 mm (9.6 × 4.0 × 5.0 in)
Weight660 g (23.3 oz)
Supported Units% v/v (at 15 °C or 20 °C), Proof, °Brix, °Plato, and 10 programmable custom units
Data Storage1024 measurements, 250 sample IDs, 30 user-defined methods
ConnectivityBluetooth® (firmware updates only)
ComplianceASTM D1152, ISO 3696, OIML R 22, EN 15733, EU Regulation (EC) No 1234/2007 Annex XI (alcohol determination in spirits)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDLAB
OriginBeijing, China
ModelMS-H-S
Instrument TypeMagnetic Stirrer
Max. Stirring Volume20 L (H₂O)
Speed Range0–1500 rpm
Temperature Control RangeAmbient to 340 °C
Heating Power500 W
MotorBrushless DC
DisplayAnalog Scale (Speed & Temp)
Plate MaterialEnamel or Stainless Steel
Plate DiameterØ135 mm
Safety Cut-off350 °C
IP RatingIP42
Dimensions (W×D×H)280 × 160 × 85 mm
Weight2.8 kg
Input Voltage220 VAC, 50/60 Hz
Total Power Consumption530 W
Max. Stir Bar Length80 mm
Heating Rate (1 L H₂O)6 K/min
Operating Environment5–40 °C, ≤80% RH
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHeidolph
OriginGermany
ModelHei-VAP Industrial
Capacity6–20 L
Ultimate Vacuum1 mbar
Rotation Speed6–160 rpm
Bath Temperature Range20–180 °C
Temperature Control Accuracy±1 °C
Condenser Cooling Area1.2 m²
Heating Power4000 W
Display7-inch Touchscreen
Lift MechanismMotorized
Safety FeaturesIntegrated Overtemperature Protection (cut-off at +5 °C above setpoint), Auto-refill System, Emergency Stop Button, IP42-rated Control Panel, Full PMMA & Metal Safety Enclosures
Programmability250 user-defined programs, up to 999 gradient steps per program
ComplianceDesigned for GLP/GMP environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeici
OriginShanghai, China
ModelWZS-182E
Form FactorBenchtop / Laboratory
Measurement Range(0.00–9.99) NTU
Resolution0.01 NTU
Accuracy≤ ±6%
Repeatability≤ 0.5%
Light SourceTungsten-halogen lamp
ComplianceEPA Method 180.1 & HJ 075-2017
Measurement PrinciplesNephelometric (90° scattering) and Ratio (scattering + transmission) modes
UnitsNTU, FNU, EBC
DisplayHigh-resolution LCD with intuitive UI
CalibrationBuilt-in standard curves + user-defined single/multi-point calibration
Environmental Operating TemperatureAmbient (10–30 °C)
Ingress ProtectionIP54
Included AccessoriesInstrument host, 5 x standardized turbidity vials, long-life calibration standards (20–500 NTU)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSOPOTOP
OriginShanghai, China
ModelNDJ-8S
Instrument TypeRotational Viscometer
Viscosity Range10–2×10⁶ mPa·s
Speed Settings0.3, 0.6, 1.5, 3, 6, 12, 30, 60 rpm
Accuracy (Newtonian fluids)±5%
Dimensions275 × 230 × 475 mm
Power Input110–240 V AC, 50/60 Hz
DisplayDigital LCD with English interface
Motor ControlMicroprocessor-controlled synchronous motor
ComplianceDesigned for routine QC and R&D use in accordance with ISO 2555 and ASTM D2196 principles
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJingHong
OriginShanghai, China
ModelTHZ-320
Timer Range0–99.9 h
Oscillation Frequency30–280 rpm
Orbit Diameter28 mm
Temperature RangeRT + 5°C to 50°C
Platform Layers1
Capacity22 × 250 mL flasks
Instrument TypeOrbital Incubator Shaker
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginAustria
ModelCora 100
Instrument TypeHandheld Raman Spectrometer
Spectral Range400–2300 cm⁻¹
Spectral Resolution≤10 cm⁻¹
Spatial Resolution<1 mm
Minimum Wavenumber400 cm⁻¹
Spectral ReproducibilityHigh repeatability across repeated measurements on identical samples
Laser Wavelength785 nm
Laser Power at Sample>215 mW (output: 300 mW)
DetectorLinear CCD Array
Display3.5″ Transmissive TFT with LED Backlight
Operating SystemEmbedded Linux
Data FormatText (.txt, .csv, .spc)
InterfaceUSB 2.0
BatteryRechargeable Li-ion (≈60 scans per charge, non-user-replaceable)
Dimensions15.8 × 10.1 × 2.9 cm
Weight650 g
IP RatingIP67
Operating Temperature−20 °C to +40 °C
Storage Temperature−30 °C to +50 °C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMETTLER TOLEDO
OriginBeijing, China
ModelLE2002E
TypeAnalytical Balance
Max Capacity2200.0 g
Readability0.01 g
Accuracy±0.02 g
Repeatability±0.01 g
CalibrationExternal
Pan Size180.0 mm
Power SupplyAC Mains
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSOPTOP
OriginShanghai, China
ModelJA2003
Maximum Capacity200 g
Readability1 mg
Repeatability±1 mg
Linearity±2 mg
Pan DiameterΦ110 mm
Draft Shield Dimensions (W×D×H)190 × 205 × 225 mm
External Dimensions (W×D×H)215 × 330 × 325 mm
CalibrationExternal
DisplayBacklit LCD
InterfaceRS232
Weighing Unitsg, oz, ct, etc.
FeaturesElectromagnetic force sensor, draft shield with five-sided glass, dynamic temperature compensation, adjustable weighing speed, auto-zero tracking, overload protection & alarm, full-range tare, counting function, under-hook weighing
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSOP TOP
OriginShanghai, China
ModelAE523J
Maximum Capacity520 g
Readability0.001 g
Repeatability (Standard Deviation)0.001 g
CalibrationExternal
Pan DiameterØ90 mm
Draft Shield Internal Volume160 × 165 × 200 mm
Dimensions (W×D×H)365 × 223 × 338 mm
Net Weight6 kg
Power SupplyAC 100–240 V, 50/60 Hz
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0