- All
- Favorite
- Popular
- Most rated
| Brand | JingHong |
|---|---|
| Origin | Shanghai, China |
| Model | SXL-1008 |
| Type | Box-Type Muffle Furnace |
| Max Temperature | 1000 °C |
| Temperature Control Accuracy | ±3 °C |
| Rated Power | 4000 W |
| Heating Rate | 300–1000 °C (typical ramp) |
| Heating Method | Resistance Wire Heating |
| Internal Chamber Dimensions | 200 × 300 × 120 mm (W × D × H) |
| Temperature Range | 300–1000 °C |
| Controller | 30-Stage Programmable Digital PID Controller |
| Safety Interlock | Automatic Power Cut-off on Door Opening/Closing |
| Brand | SuJing Antai |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SW-CJ-2FD |
| Instrument Category | Vertical Laminar Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (equivalent to Fed. Std. 209E Class 100) |
| Noise Level | ≤62 dB(A) |
| User Capacity | Dual-operator, single-face configuration |
| Airflow Pattern | Vertical downward laminar flow |
| Average Air Velocity | 0.3–0.6 m/s (adjustable) |
| Vibration (Half-Peak) | ≤5 µm |
| Illuminance | ≥300 lx |
| Power Supply | AC 220 V, 50 Hz, Single-phase |
| Max. Power Consumption | 0.8 kW |
| Net Weight | 350 kg |
| Work Area Dimensions (W×D×H) | 1360 × 700 × 520 mm |
| Overall Dimensions (W×D×H) | 1480 × 720 × 1600 mm |
| Microbial Count | ≤0.5 CFU/plate·hour (90 mm Petri dish) |
| Work Surface Material | Imported stainless steel (AISI 304) |
| Brand | SoopTop |
|---|---|
| Origin | Shanghai, China |
| Model | AE124C |
| Type | Analytical Balance |
| Maximum Capacity | 120 g |
| Readability | 0.0001 g |
| Repeatability (Standard Deviation) | 0.0001 g |
| Calibration | Internal |
| Pan Diameter | Ø90 mm |
| Dimensions (W×D×H) | 365 × 223 × 338 mm |
| Net Weight | 5.5 kg |
| Windshield Effective Volume | 160 × 165 × 200 mm |
| Brand | Kedao |
|---|---|
| Origin | Shanghai, China |
| Model | SK-HP Series |
| Instrument Type | General-Purpose Ultrasonic Cleaner |
| Tank Capacity | 3–22.5 L |
| Ultrasonic Frequency | 53 kHz |
| Ultrasonic Power Output | 100–500 W |
| Power Adjustment Range | 40–100% (1% incremental steps) |
| Timer Range | 1–999 min |
| Lid with Sound-Dampening Design | Yes |
| Drain Valve | Available on select models |
| Heating Function | Not equipped |
| Temperature Display | Real-time ambient tank temperature (non-heating mode) |
| Display | Backlit LCD with menu-driven interface |
| Tank Material | AISI 304 stainless steel |
| Power Failure Memory | Yes |
| Brand | DLAB |
|---|---|
| Origin | Beijing, China |
| Model | D3024R |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 200–15,000 rpm (adjustable in 10 rpm increments) |
| Max RCF | 21,380 ×g (adjustable in 10 ×g increments) |
| Temperature Range | −20 °C to +40 °C |
| Max Capacity | 2 mL × 24 |
| Refrigerant | Eco-friendly non-CFC |
| Drive Motor | Brushless DC motor |
| Dimensions (L×D×H) | 338 × 580 × 324 mm |
| Weight | 30 kg |
| Safety | Dual interlocked lid, overspeed protection, overtemperature cutoff, real-time diagnostics |
| Power Input | AC 220–240 V, 50/60 Hz, 10 A or AC 100–120 V, 50/60 Hz, 10 A |
| Timer | 30 s to 99 min or HOLD mode |
| Additional Functions | rpm/×g conversion, quick-spin (short-time run), progress bar display, audible end-of-run signal |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Model | JPB-607A |
| Instrument Type | Portable |
| Measurement Principle | Electrochemical (Clark-type Polarographic Probe) |
| Measurement Range | Dissolved Oxygen: (0.0–20.0) mg/L |
| Temperature | (0.0–40.0) °C |
| Accuracy | ±0.30 mg/L (DO), ±0.5 °C (Temperature) |
| Repeatability | ±0.1 mg/L |
| Stability | ±0.10 mg/L over 3 h |
| Response Time | ≤45 s to 90% of final value at 20 °C |
| Zero Oxygen Error | ≤0.10 mg/L |
| Power Supply | Two AA alkaline batteries |
| Display | 3.5-digit LCD with optional blue backlight |
| Calibration | Zero-oxygen and saturated-air (full-scale) calibration supported |
| Temperature Compensation | Automatic, integrated thermistor |
| Brand | SOPTOP |
|---|---|
| Origin | Shanghai, China |
| Model | NDJ-1 |
| Instrument Type | Analog Rotational Viscometer |
| Viscosity Range | 1–100,000 mPa·s |
| Rotational Speeds | 6 / 12 / 30 / 60 rpm |
| Spindle Set | LV Spindles #1–#4 |
| Accuracy (Newtonian Fluids) | ±5% |
| Dimensions (W×D×H) | 275 × 265 × 445 mm |
| Display | Analog Pointer Gauge |
| Speed Control | Manual Gear Shift |
| Brand | Sartorius |
|---|---|
| Origin | Shanghai, China |
| Model | BCE2202-1CCN |
| Type | Precision Balance |
| Maximum Capacity | 2200 g |
| Readability | 10 mg |
| Repeatability | ≤ ±10 mg |
| Calibration | External |
| Pan Size | Rectangular |
| Connectivity | USB-C + RS232 (9-pin) |
| Compliance | GLP/GMP-compliant data output |
| Operating Languages | 8 (English, German, French, Italian, Spanish, Portuguese, Russian, Polish) |
| Environmental Protection | PBT housing, stainless steel & coated glass draft shield |
| Features | @start self-test, isoCAL auto-adjustment (time- and temperature-triggered), anti-static design, overload protection, large weighing chamber with removable sliding doors |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model | ME203E |
| Instrument Type | Precision Balance |
| Maximum Capacity | 220 g |
| Readability | 0.001 g |
| Repeatability | 0.001 g |
| Linearity | ±0.002 g |
| Calibration Method | External (using certified weights) |
| Pan Size | 120 mm diameter |
| Draft Shield Height | 170 mm |
| Dimensions (W×D×H) | 210 × 319 × 289 mm |
| Power Supply | AC adapter (included) |
| Key | Brand: Sartorius |
|---|---|
| Origin | Shanghai, China |
| Model | BCA2202i-1OCN |
| Type | Precision Balance |
| Max Capacity | 2200 g |
| Readability | 10 mg |
| Repeatability | ≤ ±10 mg |
| Calibration | Internal (isoCAL) |
| Pan Size | Rectangular |
| Compliance | GLP/GMP-compliant data output, CalAuditTrail, ISO/IEC 17025-supportive operation |
| Connectivity | Dual USB-C, RS-232 (9-pin), optional printer/U-disk interface |
| Display | Graphical touchscreen with LED backlight |
| Languages | 13 built-in (including English, German, French, Spanish, Chinese, Japanese, Korean, etc.) |
| User Management | Up to 10 user profiles with multi-level password protection |
| Brand | Kedao |
|---|---|
| Origin | Shanghai, China |
| Model | SK-HP Series (Heating Type) |
| Ultrasonic Frequency | 53 kHz |
| Ultrasonic Power Range | 100–500 W |
| Power Adjustment | 40–100% in 1% increments |
| Heating Temperature Range | 20–60 °C |
| Timer Range | 1–199 min |
| Tank Material | 304 Stainless Steel |
| Tank Capacity | 3–22.5 L |
| Drain Valve | Included on select models |
| Sound-Dampening Lid | Standard |
| Dry-Run Protection | Yes (auto-shutoff with temperature-based no-water detection) |
| Brand | DLAB |
|---|---|
| Origin | Beijing, China |
| Model | SK-O330-Pro |
| Oscillation Mode | Orbital |
| Orbit Diameter (Amplitude) | 10 mm |
| Speed Range | 100–500 rpm |
| Timer Range | 1–1199 min |
| Platform Quantity | 1 |
| Max Load Capacity (with clamp) | 7.5 kg |
| Display | LCD |
| Motor Type | Brushless DC |
| Input/Output Power | 28 W / 15 W |
| Protection Rating | IP21 |
| Interface | RS232 |
| Temperature Range | Ambient Only |
| Clamp Compatibility | Universal (interchangeable) |
| Brand | SOPTOP |
|---|---|
| Origin | Shanghai, China |
| Model | 752 |
| Optical System | Single-beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 200–1000 nm |
| Spectral Bandwidth | 4 nm |
| Wavelength Accuracy | ±2.0 nm |
| Wavelength Repeatability | 1 nm |
| Stray Light | ≤0.5% T (at 220 nm and 360 nm) |
| Transmittance Accuracy | ±0.5% T |
| Transmittance Repeatability | ±0.2% T |
| Baseline Drift | ±0.003 A/h |
| Display | 128×64 LCD |
| Dimensions | 455 × 430 × 220 mm |
| Data Interface | USB |
| Wavelength Setting | Manual (keyboard-input with 6 preset wavelengths) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model | LE3002E |
| Type | Precision Balance |
| Max Capacity | 3200.0 g |
| Readability | 0.01 g |
| Repeatability | 0.01 g |
| Calibration | External |
| Pan Size | 180.0 mm |
| Power Supply | AC |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | Snap 41 |
| Instrument Type | Portable Digital Alcohol Meter |
| Measurement Principle | U-tube Oscillation Density Method |
| Density Range (for Ethanol-Water Solutions) | 0–100 % v/v alcohol |
| Temperature Range (Measurement) | 5–30 °C (41–86 °F) with Automatic Temperature Compensation |
| Accuracy | ±0.2 % v/v alcohol, ±0.2 °C temperature |
| Repeatability (Std. Dev.) | ±0.1 % v/v alcohol, ±0.1 °C |
| Resolution | 0.01 % v/v alcohol, 0.1 °C |
| Sample Volume | 2 mL |
| Operating Ambient Temperature | 0–35 °C (32–95 °F) |
| Display | Digital LCD |
| Environmental Rating | IP54 |
| Power Supply | 3 × 1.5 V LR06 (AA) alkaline batteries |
| Dimensions | 245 × 103 × 126 mm (9.6 × 4.0 × 5.0 in) |
| Weight | 660 g (23.3 oz) |
| Supported Units | % v/v (at 15 °C or 20 °C), Proof, °Brix, °Plato, and 10 programmable custom units |
| Data Storage | 1024 measurements, 250 sample IDs, 30 user-defined methods |
| Connectivity | Bluetooth® (firmware updates only) |
| Compliance | ASTM D1152, ISO 3696, OIML R 22, EN 15733, EU Regulation (EC) No 1234/2007 Annex XI (alcohol determination in spirits) |
| Brand | DLAB |
|---|---|
| Origin | Beijing, China |
| Model | MS-H-S |
| Instrument Type | Magnetic Stirrer |
| Max. Stirring Volume | 20 L (H₂O) |
| Speed Range | 0–1500 rpm |
| Temperature Control Range | Ambient to 340 °C |
| Heating Power | 500 W |
| Motor | Brushless DC |
| Display | Analog Scale (Speed & Temp) |
| Plate Material | Enamel or Stainless Steel |
| Plate Diameter | Ø135 mm |
| Safety Cut-off | 350 °C |
| IP Rating | IP42 |
| Dimensions (W×D×H) | 280 × 160 × 85 mm |
| Weight | 2.8 kg |
| Input Voltage | 220 VAC, 50/60 Hz |
| Total Power Consumption | 530 W |
| Max. Stir Bar Length | 80 mm |
| Heating Rate (1 L H₂O) | 6 K/min |
| Operating Environment | 5–40 °C, ≤80% RH |
| Brand | Heidolph |
|---|---|
| Origin | Germany |
| Model | Hei-VAP Industrial |
| Capacity | 6–20 L |
| Ultimate Vacuum | 1 mbar |
| Rotation Speed | 6–160 rpm |
| Bath Temperature Range | 20–180 °C |
| Temperature Control Accuracy | ±1 °C |
| Condenser Cooling Area | 1.2 m² |
| Heating Power | 4000 W |
| Display | 7-inch Touchscreen |
| Lift Mechanism | Motorized |
| Safety Features | Integrated Overtemperature Protection (cut-off at +5 °C above setpoint), Auto-refill System, Emergency Stop Button, IP42-rated Control Panel, Full PMMA & Metal Safety Enclosures |
| Programmability | 250 user-defined programs, up to 999 gradient steps per program |
| Compliance | Designed for GLP/GMP environments |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Model | WZS-182E |
| Form Factor | Benchtop / Laboratory |
| Measurement Range | (0.00–9.99) NTU |
| Resolution | 0.01 NTU |
| Accuracy | ≤ ±6% |
| Repeatability | ≤ 0.5% |
| Light Source | Tungsten-halogen lamp |
| Compliance | EPA Method 180.1 & HJ 075-2017 |
| Measurement Principles | Nephelometric (90° scattering) and Ratio (scattering + transmission) modes |
| Units | NTU, FNU, EBC |
| Display | High-resolution LCD with intuitive UI |
| Calibration | Built-in standard curves + user-defined single/multi-point calibration |
| Environmental Operating Temperature | Ambient (10–30 °C) |
| Ingress Protection | IP54 |
| Included Accessories | Instrument host, 5 x standardized turbidity vials, long-life calibration standards (20–500 NTU) |
| Brand | SOPOTOP |
|---|---|
| Origin | Shanghai, China |
| Model | NDJ-8S |
| Instrument Type | Rotational Viscometer |
| Viscosity Range | 10–2×10⁶ mPa·s |
| Speed Settings | 0.3, 0.6, 1.5, 3, 6, 12, 30, 60 rpm |
| Accuracy (Newtonian fluids) | ±5% |
| Dimensions | 275 × 230 × 475 mm |
| Power Input | 110–240 V AC, 50/60 Hz |
| Display | Digital LCD with English interface |
| Motor Control | Microprocessor-controlled synchronous motor |
| Compliance | Designed for routine QC and R&D use in accordance with ISO 2555 and ASTM D2196 principles |
| Brand | JingHong |
|---|---|
| Origin | Shanghai, China |
| Model | THZ-320 |
| Timer Range | 0–99.9 h |
| Oscillation Frequency | 30–280 rpm |
| Orbit Diameter | 28 mm |
| Temperature Range | RT + 5°C to 50°C |
| Platform Layers | 1 |
| Capacity | 22 × 250 mL flasks |
| Instrument Type | Orbital Incubator Shaker |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | Cora 100 |
| Instrument Type | Handheld Raman Spectrometer |
| Spectral Range | 400–2300 cm⁻¹ |
| Spectral Resolution | ≤10 cm⁻¹ |
| Spatial Resolution | <1 mm |
| Minimum Wavenumber | 400 cm⁻¹ |
| Spectral Reproducibility | High repeatability across repeated measurements on identical samples |
| Laser Wavelength | 785 nm |
| Laser Power at Sample | >215 mW (output: 300 mW) |
| Detector | Linear CCD Array |
| Display | 3.5″ Transmissive TFT with LED Backlight |
| Operating System | Embedded Linux |
| Data Format | Text (.txt, .csv, .spc) |
| Interface | USB 2.0 |
| Battery | Rechargeable Li-ion (≈60 scans per charge, non-user-replaceable) |
| Dimensions | 15.8 × 10.1 × 2.9 cm |
| Weight | 650 g |
| IP Rating | IP67 |
| Operating Temperature | −20 °C to +40 °C |
| Storage Temperature | −30 °C to +50 °C |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Beijing, China |
| Model | LE2002E |
| Type | Analytical Balance |
| Max Capacity | 2200.0 g |
| Readability | 0.01 g |
| Accuracy | ±0.02 g |
| Repeatability | ±0.01 g |
| Calibration | External |
| Pan Size | 180.0 mm |
| Power Supply | AC Mains |
| Brand | SOPTOP |
|---|---|
| Origin | Shanghai, China |
| Model | JA2003 |
| Maximum Capacity | 200 g |
| Readability | 1 mg |
| Repeatability | ±1 mg |
| Linearity | ±2 mg |
| Pan Diameter | Φ110 mm |
| Draft Shield Dimensions (W×D×H) | 190 × 205 × 225 mm |
| External Dimensions (W×D×H) | 215 × 330 × 325 mm |
| Calibration | External |
| Display | Backlit LCD |
| Interface | RS232 |
| Weighing Units | g, oz, ct, etc. |
| Features | Electromagnetic force sensor, draft shield with five-sided glass, dynamic temperature compensation, adjustable weighing speed, auto-zero tracking, overload protection & alarm, full-range tare, counting function, under-hook weighing |
| Brand | SOP TOP |
|---|---|
| Origin | Shanghai, China |
| Model | AE523J |
| Maximum Capacity | 520 g |
| Readability | 0.001 g |
| Repeatability (Standard Deviation) | 0.001 g |
| Calibration | External |
| Pan Diameter | Ø90 mm |
| Draft Shield Internal Volume | 160 × 165 × 200 mm |
| Dimensions (W×D×H) | 365 × 223 × 338 mm |
| Net Weight | 6 kg |
| Power Supply | AC 100–240 V, 50/60 Hz |