HORIBA 8203-10C Calcium Ion-Selective Electrode

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand HORIBA
Origin Japan
Model 8203-10C
Measuring Range 0.4–40,080 ppm Ca²⁺
Compatible Reference Electrodes 2060A and 2565A
Part Number 3014068839 (9003017000)
Compliance Designed for ASTM D511, ISO 10523, and EPA Method 300.0-compatible water analysis workflows

Overview

The HORIBA 8203-10C is a high-stability, liquid-membrane-type calcium ion-selective electrode (ISE) engineered for precise, direct potentiometric measurement of free Ca²⁺ activity in aqueous samples. Based on the principle of selective ion exchange across a polymeric PVC membrane doped with a calcium-specific ionophore (e.g., ETH 1001 or equivalent), the electrode generates a Nernstian response—approximately +29.5 mV per decade change in Ca²⁺ activity at 25 °C—enabling quantitative determination without sample digestion or derivatization. It is optimized for use with HORIBA’s benchtop (F-72/F-73/F-74/F-74BW) and portable (D-53) water quality analyzers, and functions as a critical component in routine compliance monitoring for drinking water, wastewater effluent, surface water, and industrial process streams. Unlike composite electrodes, the 8203-10C requires external reference electrodes (2060A and/or 2565A) to complete the electrochemical cell, allowing flexible configuration, independent calibration, and enhanced diagnostic capability during GLP/GMP-aligned testing.

Key Features

  • Stable, reproducible Nernstian slope (>95% theoretical) over full operational range (0.4–40,080 ppm Ca²⁺, equivalent to ~10⁻⁵–10⁻¹ M)
  • Low detection limit of 0.4 ppm Ca²⁺ (≈10 µM), suitable for soft water and low-hardness applications
  • Robust epoxy-body construction with integrated temperature sensor (Pt1000) for automatic temperature compensation (ATC)
  • Optimized membrane formulation resistant to common interferences including Mg²⁺, Na⁺, K⁺, and NH₄⁺ under controlled pH (pH 4–11)
  • Compatible with standard BNC connectors and HORIBA’s proprietary ISE interface modules (e.g., F-74 main unit, D-53 handheld base)
  • Calibration-ready design supporting two-point (e.g., 10 ppm and 1000 ppm Ca²⁺) or multi-point protocols per ISO 17025 validation requirements

Sample Compatibility & Compliance

The 8203-10C is validated for use in natural waters, treated drinking water, cooling tower fluids, boiler feedwater, and municipal wastewater. Sample pH must be maintained between 4.0 and 11.0; outside this range, hydrolysis or carbonate precipitation may suppress free Ca²⁺ activity and bias results. For high-ionic-strength matrices (e.g., seawater, brines), ionic strength adjustment via total ionic strength adjustment buffer (TISAB) is recommended to ensure activity–concentration equivalence. The electrode conforms to measurement principles referenced in ASTM D511 (Calcium in Water), ISO 10523 (pH and ion measurements in water), and EPA Method 300.0 (Ion Chromatography and ISE Screening for Anions/Cations). When used within validated instrument platforms (e.g., F-74BW), it supports audit-ready data generation compliant with 21 CFR Part 11 for electronic records and signatures.

Software & Data Management

When paired with HORIBA’s F-series analyzers or D-53 field meter, the 8203-10C integrates with embedded firmware supporting real-time slope calculation, drift monitoring, and calibration history logging. Data export is available via USB or RS-232 to HORIBA’s optional LabStation software (v4.2+), which provides automated report generation (PDF/CSV), trend analysis, and compliance templates aligned with ISO/IEC 17025 documentation standards. All calibration events—including date/time stamp, operator ID, standard concentrations, measured mV values, and calculated slope/intercept—are stored with immutable audit trails. Optional LIMS connectivity enables direct upload to laboratory information management systems meeting GLP audit requirements.

Applications

  • Regulatory compliance testing for calcium hardness in drinking water per WHO and EU Drinking Water Directive (98/83/EC)
  • Monitoring Ca²⁺ scaling potential in industrial cooling systems and reverse osmosis pre-treatment
  • Quality control of calcium-fortified beverages and pharmaceutical excipient solutions
  • Environmental assessment of freshwater eutrophication indicators and cation balance in acid-sensitive lakes
  • Process optimization in lime softening, ion exchange regeneration, and desalination plant feedwater characterization
  • Research-grade ion activity profiling in soil leachate and groundwater geochemical studies

FAQ

What reference electrodes are mandatory for the 8203-10C?

The 8203-10C requires either the HORIBA 2060A (Ag/AgCl double-junction) or 2565A (KCl-saturated calomel) reference electrode—or both in tandem—to establish a stable, low-noise electrochemical cell.
Can the 8203-10C be used with the D-53 portable analyzer?

No—the D-53 accepts only composite ISEs (e.g., 6583-10C). The 8203-10C is designed exclusively for benchtop F-series instruments (F-72, F-73, F-74, F-74BW) that support separate reference electrode inputs.
How often should the electrode be calibrated?

Daily calibration is recommended for routine QC; verification with a mid-range standard should occur before each analytical batch per ISO/IEC 17025 clause 7.7.
Is the electrode compatible with acidic or high-fluoride samples?

Avoid prolonged exposure to pH 10 ppm, as both conditions accelerate membrane leaching and reduce service life.
What is the typical service life under proper storage and handling?

With regular reconditioning (overnight soaking in 100 ppm Ca²⁺ solution) and dry storage in protective cap, functional lifespan exceeds 18 months in moderate-use laboratories.