Empowering Scientific Discovery

JEIO TECH MS-33MH & MS-53MH Multi-Position Magnetic Hotplate Stirrers

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand JEIO TECH
Origin South Korea
Model MS-33MH / MS-53MH
Instrument Type Magnetic Hotplate Stirrer
Max. Stirring Capacity 15 positions
Speed Range 30–2000 rpm
Temperature Range Ambient to 120 °C
Heating Power 600 W (MS-33MH) / 1000 W (MS-53MH)
Plate Material Anodized Aluminum
Control System PID with Digital VFD Display
Safety Features Overtemperature cutoff, overload current protection, spill-resistant housing, non-slip silicone feet
Dimensions (W×D×H) 395×450×104 mm (MS-33MH) / 395×614×104 mm (MS-53MH)
Weight 10 kg / 15 kg
Power Supply 120 V / 230 V, 50/60 Hz

Overview

The JEIO TECH MS-33MH and MS-53MH are precision-engineered multi-position magnetic hotplate stirrers designed for high-throughput laboratory environments where parallel sample processing, thermal homogeneity, and independent parameter control are essential. These instruments operate on the principle of rotating magnetic fields generated by embedded coil arrays beneath anodized aluminum heating plates—each position driven by a dedicated brushless DC motor and independently regulated via digital PID feedback. Unlike single-station units, the MS-series enables simultaneous, decoupled control of stirring speed and heating temperature across up to 9 (MS-33MH) or 15 (MS-53MH) discrete positions—making them ideal for method development, QC batch testing, dissolution studies, reagent synthesis, and cell culture media preparation under standardized thermal and mechanical conditions.

Key Features

  • Independent per-position control: Each station features discrete speed (30–2000 rpm) and temperature (ambient to 120 °C) regulation, supporting flexible operation modes—including individual, row-wise, column-wise, or global synchronization.
  • High-efficiency thermal architecture: Anodized aluminum plates provide rapid heat transfer and uniform surface temperature distribution; integrated PID controllers maintain ±1 °C stability over extended durations.
  • Brushless DC motor system: Delivers consistent torque output and smooth acceleration—even with high-viscosity media—enabling reliable coupling with standard PTFE- or glass-coated stir bars (up to Ø8 × L51 mm).
  • Digital vacuum fluorescent display (VFD): Offers real-time visibility of setpoints, actual values, elapsed time, and status indicators (e.g., heating active, motor running, safety lock engaged).
  • Robust safety engineering: Includes automatic thermal shutdown at plate overtemperature, electronic current limiting to prevent motor stall damage, IP20-rated spill-resistant enclosure, and anti-slip silicone base pads compliant with ISO 13857 ergonomic guidelines.
  • Programmable timer function: Supports interval-based operation from 1 minute to 99 hours 59 minutes, enabling unattended overnight protocols without manual intervention.

Sample Compatibility & Compliance

The MS-series accommodates standard laboratory glassware including beakers (50–1000 mL), Erlenmeyer flasks, and custom reaction vessels up to 30 kg total load capacity. Stir bar compatibility spans octahedral, cylindrical, and elliptical geometries (Ø5–10 mm × L10–51 mm), with optional PTFE- or PP-handled retrieval tools available for contamination-sensitive workflows. The instrument meets IEC 61010-1:2010 safety requirements for electrical equipment used in laboratory environments and conforms to electromagnetic compatibility standards EN 61326-1. Its closed-loop temperature control supports GLP-compliant documentation when paired with external data loggers; while not natively 21 CFR Part 11 compliant, audit-trail functionality can be implemented via third-party validated software integration.

Software & Data Management

Though standalone operation is fully functional via front-panel controls, the MS-series supports optional RS-232/USB interface modules (sold separately) for integration into centralized lab automation platforms. When connected, users may export timestamped logs of speed, temperature, and runtime per position using JEIO TECH’s proprietary LabLink software—compatible with Windows-based LIMS and ELN systems. All configuration changes are retained in non-volatile memory, ensuring reproducibility across sessions. Firmware updates are performed via USB flash drive, adhering to ISO/IEC 17025 traceability requirements for instrument calibration history.

Applications

  • Pharmaceutical QC: Parallel dissolution testing per USP , buffer equilibration, and excipient dispersion under controlled thermal profiles.
  • Materials science: Nanoparticle suspension stabilization, polymer solution viscosity screening, and catalyst slurry homogenization.
  • Environmental analysis: Digestion of soil/water samples prior to ICP-MS or AAS analysis, requiring precise ramp-and-hold thermal protocols.
  • Academic research: High-throughput enzyme kinetics assays, microbial growth medium preparation, and combinatorial chemistry reaction screening.
  • Food & beverage R&D: Emulsion stability assessment, flavor compound extraction, and pH-adjusted mixing of viscous dairy or plant-based formulations.

FAQ

What is the maximum recommended vessel size per position?
Standard operation supports round-bottom or flat-bottom containers up to 1000 mL volume; optimal performance is achieved with vessels having base diameters between 40–85 mm, matching the defined spacing of 117 × 90 mm (MS-33MH) or equivalent grid layout (MS-53MH).
Can the MS-series be used with corrosive or organic solvents?
Yes—the anodized aluminum plate surface and sealed electronics housing resist mild chemical exposure; however, direct contact with strong acids (e.g., concentrated HNO₃), halogenated solvents, or molten salts is not advised without secondary containment.
Is calibration required before first use?
No factory calibration is needed for routine operation; however, users performing regulated work should verify temperature accuracy annually using NIST-traceable thermometers and document deviations per ISO/IEC 17025 clause 6.5.
How does the system handle viscous samples during startup?
The brushless DC motor delivers high starting torque with soft-start logic, minimizing stir bar decoupling even in glycerol-water mixtures (>1000 mPa·s) or agarose gels—provided appropriate stir bar geometry and size are selected.
Are replacement parts and stir bars supplied with the unit?
Stir bars are sold separately as configurable kits (octahedral, cylindrical, elliptical); all critical wear components—including top plates, fuse assemblies, and control boards—are available through JEIO TECH’s authorized service network with documented spare part numbers (e.g., BCW15xx series, AAHK340xxK/U).