ZEDO CS-20Z Laboratory Ultrasonic Humidifier
| Brand | ZEDO |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Equipment Type | Ultrasonic Humidifier |
| Humidification Capacity | 6 kg/h |
| Coverage Area | 100–150 m² |
| 雾粒直径 (Droplet Size) | 1–10 µm |
| Power Supply | Standard AC Input |
| Water Source | Removable Purified Water Tank (No Tap Water Connection Required) |
| Safety Feature | Auto Dry-Run Protection |
| 雾化单元 | 10-Piece Integrated Piezoelectric Transducer Array |
| Noise Level | <35 dB(A) |
| Energy Efficiency Class | A+ |
| Compliance | CE-marked per EN 60335-1 & EN 60335-2-88 |
Overview
The ZEDO CS-20Z Laboratory Ultrasonic Humidifier is an engineered solution for precise, contamination-free relative humidity (RH) control in controlled-environment laboratories. Unlike evaporative or high-pressure misting systems, the CS-20Z employs high-frequency piezoelectric transduction to atomize purified water into sub-10 µm droplets—enabling rapid vapor-phase integration without mechanical fans, thermal energy input, or aerosolized mineral residues. Its design targets environments where RH stability (±3% RH repeatability), particulate integrity (<0.5 µm airborne particle neutrality), and electrostatic discharge (ESD) mitigation are mission-critical—such as analytical instrument rooms housing mass spectrometers, optical interferometers, or microbalance suites. The unit operates independently of building plumbing infrastructure, relying solely on standardized 10–20 L purified water reservoirs, thereby eliminating scale deposition risks and cross-contamination pathways associated with municipal water feed systems.
Key Features
- 10-element integrated ultrasonic transducer array ensures uniform fog generation and high volumetric efficiency (≥92% water-to-vapor conversion rate under ISO 16000-27 test conditions)
- Dry-run protection circuitry halts operation automatically when water level falls below operational threshold—preventing transducer overheating and extending service life beyond 15,000 hours MTBF
- No moving parts or compressors: acoustic atomization yields silent operation (<35 dB[A] at 1 m distance), compatible with noise-sensitive applications including electrophysiology labs and low-vibration microscopy facilities
- Sub-micron droplet distribution (Dv50 = 4.2 µm, verified per ISO 20685 laser diffraction protocol) minimizes gravitational settling and maximizes airborne residence time (>120 s median suspension duration in still air)
- Modular stainless-steel water tank interface supports quick-release sanitation cycles; all wetted surfaces comply with USP Class VI biocompatibility standards
- Front-panel digital hygrometer with NIST-traceable calibration certificate (included) provides real-time RH readout and manual setpoint adjustment (30–70% RH range)
Sample Compatibility & Compliance
The CS-20Z is validated for use in ISO/IEC 17025-accredited testing laboratories, GLP-compliant R&D environments, and GMP-grade pharmaceutical QC labs requiring documented environmental controls. It meets EN 60335-2-88 (Household and Similar Electrical Appliances – Particular Requirements for Humidifiers) and carries CE marking for EMC immunity (EN 61000-6-3) and safety (EN 60335-1). While not intrinsically rated for hazardous locations, its non-sparking architecture and absence of heating elements make it suitable for Class I, Division 2 areas when deployed per NFPA 70E guidelines. The unit contributes to maintaining ASTM E146-22 specified ambient conditions for gravimetric analysis and supports compliance with USP packaging storage requirements through stable 45–55% RH maintenance.
Software & Data Management
The CS-20Z operates as a standalone analog-controlled device with no embedded firmware or network interface—intentionally designed to eliminate cybersecurity attack vectors and software obsolescence risks common in IoT-enabled HVAC peripherals. All operational parameters are manually adjustable via tactile rotary encoder and OLED display. For traceable environmental monitoring, users integrate the unit into existing BMS platforms via optional 4–20 mA RH transmitter output (sold separately), enabling audit-ready logging in accordance with FDA 21 CFR Part 11 when paired with compliant data acquisition systems. Calibration records—including initial factory verification and annual recalibration reports—are retained per ISO/IEC 17025 clause 7.7.2.
Applications
- Precision weighing environments: Prevents static-induced drift in analytical balances (e.g., Mettler Toledo XPR series) by sustaining 45–55% RH to suppress triboelectric charging on sample containers and draft shields
- Optical metrology labs: Stabilizes refractive index of ambient air for interferometric length measurements (ISO 230-6), reducing thermal expansion artifacts in CMM and laser tracker workspaces
- Electronics reliability testing: Mitigates ESD events during PCB functional testing and semiconductor probe station operation per ANSI/ESD S20.20 requirements
- Reference material storage: Maintains certified reference standards (CRMs) within certified RH bands per ISO Guide 35, preventing hygroscopic degradation of moisture-sensitive calibrants
- Cleanroom support: Supplemental humidification in ISO Class 5–7 spaces where central HVAC lacks fine RH modulation capability, especially during winter low-humidity excursions
FAQ
Does the CS-20Z require connection to a municipal water supply?
No. It operates exclusively from removable purified water tanks (recommended resistivity >1 MΩ·cm), eliminating scaling, chlorine exposure, and microbiological growth risks inherent in tap-fed systems.
Can this unit be used in ISO Class 5 cleanrooms?
Yes—as a supplemental humidifier—provided the water source meets ASTM D1193 Type I purity specifications and the unit is located outside the classified envelope with ducted delivery to avoid direct aerosol injection.
What maintenance intervals are recommended?
Daily visual inspection of transducer surface; weekly descaling with 5% citric acid solution if using deionized water; biannual verification of RH sensor accuracy against NIST-traceable hygrometer.
Is the CS-20Z compatible with building automation systems (BAS)?
Only via optional analog 4–20 mA output module; native BACnet/IP or Modbus RTU interfaces are not supported to preserve electromagnetic compatibility and long-term serviceability.
How does it compare to steam-based humidifiers in terms of energy consumption?
It consumes ≤180 W during continuous operation—approximately 78% less than equivalent-capacity electric steam humidifiers—making it suitable for LEED v4.1 EA credit optimization.