Jiada Xiaotianshe GDYS-102SL Chloride Analyzer

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Jiada Xiaotianshe
Origin Jilin, China
Manufacturer Type Direct Manufacturer
Country of Origin China
Model GDYS-102SL
Pricing Upon Request
Detection Limit 20.0 mg/L
Measurement Range 0.0–500.0 mg/L
Accuracy ±5%

Overview

The Jiada Xiaotianshe GDYS-102SL Chloride Analyzer is a dedicated photometric instrumentation system engineered for rapid, field-deployable quantification of chloride ions (Cl⁻) in aqueous environmental samples. It operates on the principle of colorimetric analysis using the mercury thiocyanate spectrophotometric method—standardized in ISO 9297 and aligned with EPA Method 325.1 for chloride determination in drinking water and natural waters. The instrument integrates a fixed-wavelength (460 nm) LED light source, precision optical path design, and calibrated reference cuvettes to deliver consistent absorbance measurements. Its compact benchtop form factor and low-power consumption support both laboratory-based routine monitoring and mobile deployment in water utility field labs or environmental assessment teams. Designed for compliance-driven workflows, the GDYS-102SL supports traceable calibration verification and meets fundamental performance criteria for Class II water quality analyzers under China’s HJ/T 399–2007 standard.

Key Features

  • Optimized optical architecture featuring temperature-stabilized 460 nm LED illumination and dual-beam photodetector configuration to minimize drift and enhance signal-to-noise ratio
  • Pre-programmed calibration curves stored in non-volatile memory, eliminating manual curve entry and reducing operator-induced error
  • Dedicated reagent kit (GDYS-102SL-KIT) with shelf-stable, pre-weighed mercury thiocyanate and ferric nitrate reagents—each batch certified for lot-specific blank correction and recovery validation
  • Integrated thermal management system maintaining reaction cell temperature within ±0.5 °C during color development (5–10 min incubation at 25 °C)
  • Self-diagnostic startup sequence verifying photometric integrity, battery voltage, and cuvette alignment prior to measurement initiation
  • IP54-rated enclosure suitable for humid laboratory environments and short-duration outdoor use near sampling sites

Sample Compatibility & Compliance

The GDYS-102SL accepts clarified, particle-free liquid samples with turbidity < 5 NTU and residual chlorine < 0.5 mg/L. It is validated for use with potable water, raw surface water (rivers, lakes), groundwater (wells, springs), and treated wastewater effluents meeting WHO Guideline Limits for chloride (250 mg/L). Sample pretreatment—such as filtration through 0.45 µm membrane filters or centrifugation—is required for high-turbidity or suspended-solids-rich matrices. The analyzer complies with basic metrological requirements outlined in JJG 830–2019 (Chinese National Verification Regulation for Photometric Water Quality Analyzers) and supports documentation traceability per GLP principles. While not FDA 21 CFR Part 11–certified, its audit trail functionality—including timestamped measurement logs, operator ID input, and calibration history export—enables integration into ISO/IEC 17025–accredited laboratory quality systems.

Software & Data Management

Data acquisition and reporting are managed via embedded firmware with a 128×64 pixel monochrome LCD interface. All measurements are automatically timestamped and tagged with operator ID (numeric input). Up to 200 test records—including absorbance values, calculated concentrations, calibration dates, and QC check results—are retained onboard. Data export is supported via USB 2.0 interface to standard FAT32-formatted flash drives in CSV format, enabling direct import into LIMS platforms or statistical analysis tools (e.g., Minitab, JMP). Firmware updates are performed offline using manufacturer-provided HEX files; no cloud connectivity or remote access capability is implemented, ensuring data sovereignty and network isolation in regulated settings.

Applications

  • Routine surveillance of chloride levels in municipal drinking water distribution systems to detect intrusion from saline sources or de-icing runoff
  • Baseline characterization and trend analysis of chloride migration in aquifer monitoring wells adjacent to roadways or industrial zones
  • Compliance verification against national discharge limits (e.g., China’s GB 8978–1996 for industrial wastewater) prior to environmental reporting
  • Field screening during emergency response to saltwater intrusion events following storm surges or coastal flooding
  • Educational use in university environmental science laboratories for teaching standardized wet-chemistry analytical protocols

FAQ

What sample volume is required per test?
A minimum of 10.0 mL of filtered, room-temperature sample is required for each analysis.
Can the GDYS-102SL measure chloride in seawater or brine?
No—the upper detection limit of 500.0 mg/L is insufficient for seawater (typically ~19,000 mg/L Cl⁻); dilution is not recommended due to interference amplification and loss of accuracy below the 20.0 mg/L detection limit.
Is reagent lot traceability provided?
Yes—each GDYS-102SL-KIT includes a Certificate of Analysis listing lot number, expiration date, blank absorbance value, and recovery rate determined against NIST SRM 1643e (Trace Elements in Natural Water).
Does the instrument require annual recalibration by an accredited service provider?
While not mandatory, Jiada Xiaotianshe recommends biannual optical verification using NIST-traceable neutral density filters and annual full-system performance verification per HJ/T 399–2007 Annex B.
Are replacement cuvettes and LED modules available as spare parts?
Yes—cuvette sets (quartz, 10 mm pathlength) and field-replaceable LED assemblies are stocked under part numbers GDYS-CUV-10 and GDYS-LED-460, respectively, with documented mean time between failures (MTBF) > 15,000 hours.