Empowering Scientific Discovery

ABB (China) Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandABB
OriginCanada
ModelFTPA2000-260
TypeOnline Analyzer
PrincipleFourier Transform (FT)
Wavelength Range3800–14000 cm⁻¹
Spectral Resolution1–128 cm⁻¹ (in 2× steps)
Optical Path Difference (OPD) Scan Speed1 cm/s
Wavenumber Repeatability0.002 cm⁻¹ RMS @ 7300 cm⁻¹
Wavenumber Reproducibility0.04 cm⁻¹ RMS @ 7300 cm⁻¹
Absorbance Linearity Error≤0.1% of peak response
SNR (1 scan, 16 cm⁻¹, room-temp InGaAs)≥15,000:1 (29 µabs @ 0 abs)
Sampling ModesTransmission / Diffuse Reflectance / Transflectance
Detector OptionsThermoelectrically Cooled InAs or InGaAs
Channel Count8 independent optical channels (8-in/8-out)
Fiber InterfaceSMA-905
Fiber TypesLow-OH silica core (300–600 µm), multi-fiber bundle (650 µm, NA 0.22–0.28)
Max Fiber Length100 m (solids), 300 m (liquids)
SoftwareHorizon MB, FTSW100
ComplianceFDA 21 CFR Part 11, GMP/GLP-ready, OPC, Modbus TCP
Added to wishlistRemoved from wishlist 0
Add to compare
BrandABB
OriginCanada
ModelTALYS ASP500-OH
Instrument TypeOnline
PrincipleFourier Transform Near-Infrared (FT-NIR) Spectroscopy
Wavelength Range3800–14000 cm⁻¹
Detector OptionsInGaAs 2.1 (4550–10500 cm⁻¹), InGaAs 2.1 TE-cooled (4750–10500 cm⁻¹), InGaAs 2.6 (4000–10000 cm⁻¹)
Light SourceQuartz Halogen Lamp with Electronic Stabilization
Laser ReferenceSolid-State Laser
Spectral Resolution (Adjustable)1–64 cm⁻¹
Wavenumber Reproducibility (@7300 cm⁻¹)<0.006 cm⁻¹
Wavenumber Accuracy (@7300 cm⁻¹)<0.06 cm⁻¹
Sampling ModesTransmission, Diffuse Reflectance, Transflectance
Data Sampling IntervalBetter than 0.7 cm⁻¹
Software SuiteHorizon MB, Quantify, PLSPlus, PLS-IQ, Unscrambler
Communication ProtocolsModbus TCP (Ethernet), RS232/RS485 (via converter), OPC DA (Ethernet), CANopen (via USB-to-CAN adapter)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandABB
OriginCanada
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelGLA132
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandABB
OriginCanada
ModelMB3000
Instrument TypeLaboratory FTIR Spectrometer
Wavenumber Range490–8500 cm⁻¹
ResolutionAdjustable from 1 to 64 cm⁻¹ (2× step increments)
Signal-to-Noise Ratio50,000:1 (60 s acquisition, 4 cm⁻¹ resolution)
DetectorDTGS
Beam SplitterZnSe
InterferometerDual-pivot Michelson with high-throughput optical design
Laser SourceSolid-state laser
ADC Resolution24-bit
Wavenumber Accuracy< 0.01 cm⁻¹ (@1918 cm⁻¹)
Wavenumber Repeatability< 0.001 cm⁻¹ (@1918 cm⁻¹)
Short-term Stability< 0.09 %
Temperature Stability< 1 %/°C
Power Consumption65 W
Dimensions435 × 280 × 372 mm
Weight24 kg
ComplianceCSA, RoHS, CE
Added to wishlistRemoved from wishlist 0
Add to compare
BrandABB
OriginCanada
ModelMB3600-PH
Instrument TypeLaboratory FT-NIR Spectrometer
PrincipleFourier Transform
Spectral Range3800–14000 cm⁻¹
Spectral ResolutionAdjustable from 1 to 64 cm⁻¹ (step size: 2 cm⁻¹), nominal resolution < 0.7 cm⁻¹
Signal Sampling24-bit ADC
SNR (60 s, 16 cm⁻¹, peak response)>100,000:1 (DTGS), >600,000:1 (Extended InGaAs)
Frequency Accuracy (@ 7300 cm⁻¹)< 0.06 cm⁻¹
Frequency Reproducibility (@ 7300 cm⁻¹)< 0.006 cm⁻¹
Absorbance Reproducibility (methanol reference)< 0.002 AU
Short-term Stability (@ 8000 cm⁻¹)< 0.09 %
Temperature Stability (@ 8000 cm⁻¹)< 1 %/°C
Sampling ModesTransmission, Diffuse Reflectance, Fiber-Optic Probe
SoftwareHorizon MB Chemometrics Suite
Regulatory Compliance21 CFR Part 11, cGMP IQ/OQ Protocols Included
Added to wishlistRemoved from wishlist 0
Add to compare
BrandABB
OriginCanada
ModelGLA451-N2OI3
Measurement TargetsN₂O, δ¹⁵N, δ¹⁵Nα, δ¹⁵Nβ, δ¹⁸O, δ¹⁷O*
Detection PrincipleOff-Axis Integrated Cavity Output Spectroscopy (OA-ICOS) with Quantum Cascade Laser
Dynamic Range>20× ambient environmental concentration
Measurement FrequencyUp to 10 Hz (high-flow mode)
Sample IntroductionAutomated gas sampler or manual injection
Internal Temperature ControlYes
Data StorageOnboard computer with long-term archival capability
Output InterfacesAnalog + RS232 digital
Software IncludedInstrument control, real-time diagnostics, isotope ratio calculation and time-series analysis
Added to wishlistRemoved from wishlist 0
Add to compare
BrandABB
OriginCanada
ModelMB3600-CH80
Instrument TypeLaboratory FT-NIR Spectrometer
PrincipleFourier Transform Near-Infrared (FT-NIR)
Wavelength Range3800–14000 cm⁻¹
Data Sampling Interval< 0.7 cm⁻¹
Measurement ModeTransmission
Chemometrics SoftwareHorizon MB
Sample ThroughputNon-destructive, sub-10-second analysis per PET container
Calibration BasisPre-installed quantitative models derived from >150 real-world PET bottle measurements
Added to wishlistRemoved from wishlist 0
Add to compare
BrandABB
OriginCanada
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelMR-i
PriceUSD 2,000,000
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeDistributor
Origin CategoryImported
ModelAnalyzeIT Wet Process Analyzer
Price RangeUSD 140,000 – 280,000 (based on CIF terms)
Instrument PrincipleFourier Transform Near-Infrared (FT-NIR) Spectroscopy
Added to wishlistRemoved from wishlist 0
Add to compare
BrandABB
OriginCanada
ModelFTPA2000-PH40
Instrument TypeOnline
PrincipleFourier Transform (FT)
Wavelength Range3800–14000 cm⁻¹
Spectral Sampling Interval< 0.7 cm⁻¹
Measurement ModeDiffuse Reflectance
Chemometrics SoftwareFTSW100, Horizon MB
Optical Path Difference (OPD) Scan Speed1 cm/s
Resolution Options1–128 cm⁻¹ (in powers of two)
Wavenumber Repeatability0.002 cm⁻¹ RMS @ 7300 cm⁻¹
Wavenumber Reproducibility0.04 cm⁻¹ RMS @ 7300 cm⁻¹
Absorbance Linearity±0.1% of peak response
SNR (1 scan, 16 cm⁻¹, room temp)≥15,000:1 (extended InGaAs detector)
Long-term Spectral Stability≤2%/°C drift (4000–10000 cm⁻¹)
Beam Splitter MaterialBK7 optical glass
Added to wishlistRemoved from wishlist 0
Add to compare
BrandABB
OriginCanada
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelMB3600-HP10
Instrument TypeLaboratory
PrincipleFourier Transform Near-Infrared (FT-NIR) Spectroscopy
Wavelength Range3800–14000 cm⁻¹
Data Sampling Interval< 0.7 cm⁻¹
Measurement ModeTransmission
Chemometrics SoftwareHorizon MB
Added to wishlistRemoved from wishlist 0
Add to compare
BrandABB
OriginCanada
ModelMB3600-CH10
Instrument TypeLaboratory FT-NIR Spectrometer
PrincipleFourier Transform Near-Infrared (FT-NIR)
Wavelength Range3800–14000 cm⁻¹
Data Sampling Interval< 0.7 cm⁻¹
Measurement ModeTransmission
Chemometrics SoftwareHorizon MB
ComplianceAOCS Cd 1e-01 (IV determination)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandABB
OriginCanada
ModelTALYS ASP500-Oleochemicals
Instrument TypeOnline
PrincipleFourier Transform (FT)
Wavelength Range3800–14000 cm⁻¹
Detector OptionsInGaAs 2.1 (4550–10500 cm⁻¹), InGaAs 2.1 TE-cooled (4750–10500 cm⁻¹), InGaAs 2.6 (4000–10000 cm⁻¹)
Light SourceQuartz Halogen Lamp with Electronic Stabilization
InterferometerSolid-State Laser Referenced
Spectral Resolution (Adjustable)1–64 cm⁻¹
Wavenumber Reproducibility (@7300 cm⁻¹)<0.006 cm⁻¹
Wavenumber Accuracy (@7300 cm⁻¹)<0.06 cm⁻¹
Sampling ModesTransmission, Diffuse Reflectance, Transflectance
Data Sampling IntervalBetter than 0.7 cm⁻¹
Communication ProtocolsModbus TCP (Ethernet), RS232/RS485 (via converter), OPC DA (Ethernet), CANopen (via USB-to-CAN adapter)
Chemometrics SoftwareHorizon MB, Quantify, PLSPlus, PLSIQ, Unscrambler
Added to wishlistRemoved from wishlist 0
Add to compare
BrandABB
OriginCanada
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelGLA331
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandABB
OriginCanada
ModelGLA431
Measurement Parametersδ¹³C, δ¹⁸O, CO₂ (380–25,000 ppm), H₂O (4,000–60,000 ppm)
Precision (1σ)δ¹³C = 0.15‰ (100 s), δ¹⁸O = 1‰ (100 s), CO₂ = 0.05 ppm (100 s), H₂O = 50 ppm (300 s)
Drift (24 h, peak-to-peak)δ¹³C < 0.5‰
Max. Measurement Rate1 Hz
Form FactorRack-Mount (68 kg)
TechnologyOff-Axis Integrated Cavity Output Spectroscopy (OA-ICOS)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandABB
OriginCanada
ModelMB3600-CH20
Instrument TypeLaboratory FT-NIR Spectrometer
PrincipleFourier Transform Near-Infrared (FT-NIR)
Wavelength Range3800–14000 cm⁻¹
Data Sampling Interval< 0.7 cm⁻¹
Measurement ModeTransmission
Chemometrics SoftwareHorizon MB
ComplianceDesigned for GLP/GMP-aligned workflows, supports ASTM E1655 and ISO 12099 data handling conventions
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelMR304/170
Instrument TypeFourier Transform Infrared Spectrometer
Spectral ResolutionAdjustable up to 1 cm⁻¹
Data Interface100 Mbps Ethernet
Scan Speed≥83 Hz (12 ms per interferogram)
Field of View Options5 mrad, 28 mrad, 75 mrad
NESR<1.0 × 10⁻⁹ W·cm⁻²·sr⁻¹·cm
ComplianceASTM E1421, ISO 18356, MIL-STD-461G (EMC), GLP/GMP-ready data audit trail
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelsPIR3502, PFO3372, PUV3402
Operating PrincipleIn-situ, Online & Portable
Spectral RangesUV (190–400 nm), VIS (400–700 nm), NIR (700–2500 nm), IR (2.5–25 µm)
Wavelength ChannelsUp to 8 discrete optical bands
IntegrationCompatible with VN2300 Analyzer Network
Sampling InterfaceDirect path (PIR3502/PUV3402) and fiber-optic probe (PFO3372)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandABB
OriginCanada
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelGLA351
Measurement Rangeδ¹³C, δ¹⁷O, δ¹⁸O, and CO₂ mole fraction (150–2500 ppm, full-spec range)
Precision (1σ)δ¹³C = 0.7‰/0.25‰/0.07‰ (1 s/10 s/100 s)
Max Drift (peak-to-peak, 15-min avg, 24 h)δ¹³C < 0.5‰
Response Time (95% step)10 s (with external pump, flow response < 5 s)
Operating RangeCO₂: 0–3000 ppm
H₂O0–70,000 ppm (non-condensing)
Data OutputRS232, analog (0–5 V / 4–20 mA)
Measurement RateUp to 1 Hz (user-selectable)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandABB
OriginCanada
ModelMB-Rx
Instrument TypeIn-situ, Real-time FTIR Spectrometer
Spectral Range600–8000 cm⁻¹ (configurable by probe/fiber combination)
ResolutionAdjustable from 1 cm⁻¹ to 64 cm⁻¹ (in 2 cm⁻¹ increments)
Scan SpeedVariable, dependent on resolution and scan count
Signal-to-Noise Ratio50,000:1 (60 s acquisition, 4 cm⁻¹ resolution)
DetectorUncooled Room-Temperature Pyroelectric (DTGS)
ATR Probe MaterialsHastelloy® C-276, ZnSe, Diamond, ZrO₂
Fiber TypesSilver Halide (AgClBr), Sulfide Glass
Spectral Digitization24-bit ADC
Detection Limit0.1% w/w acetone in toluene (60 s, 4 cm⁻¹)
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0