- All
- Favorite
- Popular
- Most rated
| Brand | ABB |
|---|---|
| Origin | Canada |
| Model | FTPA2000-260 |
| Type | Online Analyzer |
| Principle | Fourier Transform (FT) |
| Wavelength Range | 3800–14000 cm⁻¹ |
| Spectral Resolution | 1–128 cm⁻¹ (in 2× steps) |
| Optical Path Difference (OPD) Scan Speed | 1 cm/s |
| Wavenumber Repeatability | 0.002 cm⁻¹ RMS @ 7300 cm⁻¹ |
| Wavenumber Reproducibility | 0.04 cm⁻¹ RMS @ 7300 cm⁻¹ |
| Absorbance Linearity Error | ≤0.1% of peak response |
| SNR (1 scan, 16 cm⁻¹, room-temp InGaAs) | ≥15,000:1 (29 µabs @ 0 abs) |
| Sampling Modes | Transmission / Diffuse Reflectance / Transflectance |
| Detector Options | Thermoelectrically Cooled InAs or InGaAs |
| Channel Count | 8 independent optical channels (8-in/8-out) |
| Fiber Interface | SMA-905 |
| Fiber Types | Low-OH silica core (300–600 µm), multi-fiber bundle (650 µm, NA 0.22–0.28) |
| Max Fiber Length | 100 m (solids), 300 m (liquids) |
| Software | Horizon MB, FTSW100 |
| Compliance | FDA 21 CFR Part 11, GMP/GLP-ready, OPC, Modbus TCP |
| Brand | ABB |
|---|---|
| Origin | Canada |
| Model | TALYS ASP500-OH |
| Instrument Type | Online |
| Principle | Fourier Transform Near-Infrared (FT-NIR) Spectroscopy |
| Wavelength Range | 3800–14000 cm⁻¹ |
| Detector Options | InGaAs 2.1 (4550–10500 cm⁻¹), InGaAs 2.1 TE-cooled (4750–10500 cm⁻¹), InGaAs 2.6 (4000–10000 cm⁻¹) |
| Light Source | Quartz Halogen Lamp with Electronic Stabilization |
| Laser Reference | Solid-State Laser |
| Spectral Resolution (Adjustable) | 1–64 cm⁻¹ |
| Wavenumber Reproducibility (@7300 cm⁻¹) | <0.006 cm⁻¹ |
| Wavenumber Accuracy (@7300 cm⁻¹) | <0.06 cm⁻¹ |
| Sampling Modes | Transmission, Diffuse Reflectance, Transflectance |
| Data Sampling Interval | Better than 0.7 cm⁻¹ |
| Software Suite | Horizon MB, Quantify, PLSPlus, PLS-IQ, Unscrambler |
| Communication Protocols | Modbus TCP (Ethernet), RS232/RS485 (via converter), OPC DA (Ethernet), CANopen (via USB-to-CAN adapter) |
| Brand | ABB |
|---|---|
| Origin | Canada |
| Model | MB3000 |
| Instrument Type | Laboratory FTIR Spectrometer |
| Wavenumber Range | 490–8500 cm⁻¹ |
| Resolution | Adjustable from 1 to 64 cm⁻¹ (2× step increments) |
| Signal-to-Noise Ratio | 50,000:1 (60 s acquisition, 4 cm⁻¹ resolution) |
| Detector | DTGS |
| Beam Splitter | ZnSe |
| Interferometer | Dual-pivot Michelson with high-throughput optical design |
| Laser Source | Solid-state laser |
| ADC Resolution | 24-bit |
| Wavenumber Accuracy | < 0.01 cm⁻¹ (@1918 cm⁻¹) |
| Wavenumber Repeatability | < 0.001 cm⁻¹ (@1918 cm⁻¹) |
| Short-term Stability | < 0.09 % |
| Temperature Stability | < 1 %/°C |
| Power Consumption | 65 W |
| Dimensions | 435 × 280 × 372 mm |
| Weight | 24 kg |
| Compliance | CSA, RoHS, CE |
| Brand | ABB |
|---|---|
| Origin | Canada |
| Model | MB3600-PH |
| Instrument Type | Laboratory FT-NIR Spectrometer |
| Principle | Fourier Transform |
| Spectral Range | 3800–14000 cm⁻¹ |
| Spectral Resolution | Adjustable from 1 to 64 cm⁻¹ (step size: 2 cm⁻¹), nominal resolution < 0.7 cm⁻¹ |
| Signal Sampling | 24-bit ADC |
| SNR (60 s, 16 cm⁻¹, peak response) | >100,000:1 (DTGS), >600,000:1 (Extended InGaAs) |
| Frequency Accuracy (@ 7300 cm⁻¹) | < 0.06 cm⁻¹ |
| Frequency Reproducibility (@ 7300 cm⁻¹) | < 0.006 cm⁻¹ |
| Absorbance Reproducibility (methanol reference) | < 0.002 AU |
| Short-term Stability (@ 8000 cm⁻¹) | < 0.09 % |
| Temperature Stability (@ 8000 cm⁻¹) | < 1 %/°C |
| Sampling Modes | Transmission, Diffuse Reflectance, Fiber-Optic Probe |
| Software | Horizon MB Chemometrics Suite |
| Regulatory Compliance | 21 CFR Part 11, cGMP IQ/OQ Protocols Included |
| Brand | ABB |
|---|---|
| Origin | Canada |
| Model | MB3600-CH80 |
| Instrument Type | Laboratory FT-NIR Spectrometer |
| Principle | Fourier Transform Near-Infrared (FT-NIR) |
| Wavelength Range | 3800–14000 cm⁻¹ |
| Data Sampling Interval | < 0.7 cm⁻¹ |
| Measurement Mode | Transmission |
| Chemometrics Software | Horizon MB |
| Sample Throughput | Non-destructive, sub-10-second analysis per PET container |
| Calibration Basis | Pre-installed quantitative models derived from >150 real-world PET bottle measurements |
| Brand | ABB |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MR-i |
| Price | USD 2,000,000 |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | AnalyzeIT Wet Process Analyzer |
| Price Range | USD 140,000 – 280,000 (based on CIF terms) |
| Instrument Principle | Fourier Transform Near-Infrared (FT-NIR) Spectroscopy |
| Brand | ABB |
|---|---|
| Origin | Canada |
| Model | FTPA2000-PH40 |
| Instrument Type | Online |
| Principle | Fourier Transform (FT) |
| Wavelength Range | 3800–14000 cm⁻¹ |
| Spectral Sampling Interval | < 0.7 cm⁻¹ |
| Measurement Mode | Diffuse Reflectance |
| Chemometrics Software | FTSW100, Horizon MB |
| Optical Path Difference (OPD) Scan Speed | 1 cm/s |
| Resolution Options | 1–128 cm⁻¹ (in powers of two) |
| Wavenumber Repeatability | 0.002 cm⁻¹ RMS @ 7300 cm⁻¹ |
| Wavenumber Reproducibility | 0.04 cm⁻¹ RMS @ 7300 cm⁻¹ |
| Absorbance Linearity | ±0.1% of peak response |
| SNR (1 scan, 16 cm⁻¹, room temp) | ≥15,000:1 (extended InGaAs detector) |
| Long-term Spectral Stability | ≤2%/°C drift (4000–10000 cm⁻¹) |
| Beam Splitter Material | BK7 optical glass |
| Brand | ABB |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MB3600-HP10 |
| Instrument Type | Laboratory |
| Principle | Fourier Transform Near-Infrared (FT-NIR) Spectroscopy |
| Wavelength Range | 3800–14000 cm⁻¹ |
| Data Sampling Interval | < 0.7 cm⁻¹ |
| Measurement Mode | Transmission |
| Chemometrics Software | Horizon MB |
| Brand | ABB |
|---|---|
| Origin | Canada |
| Model | MB3600-CH10 |
| Instrument Type | Laboratory FT-NIR Spectrometer |
| Principle | Fourier Transform Near-Infrared (FT-NIR) |
| Wavelength Range | 3800–14000 cm⁻¹ |
| Data Sampling Interval | < 0.7 cm⁻¹ |
| Measurement Mode | Transmission |
| Chemometrics Software | Horizon MB |
| Compliance | AOCS Cd 1e-01 (IV determination) |
| Brand | ABB |
|---|---|
| Origin | Canada |
| Model | TALYS ASP500-Oleochemicals |
| Instrument Type | Online |
| Principle | Fourier Transform (FT) |
| Wavelength Range | 3800–14000 cm⁻¹ |
| Detector Options | InGaAs 2.1 (4550–10500 cm⁻¹), InGaAs 2.1 TE-cooled (4750–10500 cm⁻¹), InGaAs 2.6 (4000–10000 cm⁻¹) |
| Light Source | Quartz Halogen Lamp with Electronic Stabilization |
| Interferometer | Solid-State Laser Referenced |
| Spectral Resolution (Adjustable) | 1–64 cm⁻¹ |
| Wavenumber Reproducibility (@7300 cm⁻¹) | <0.006 cm⁻¹ |
| Wavenumber Accuracy (@7300 cm⁻¹) | <0.06 cm⁻¹ |
| Sampling Modes | Transmission, Diffuse Reflectance, Transflectance |
| Data Sampling Interval | Better than 0.7 cm⁻¹ |
| Communication Protocols | Modbus TCP (Ethernet), RS232/RS485 (via converter), OPC DA (Ethernet), CANopen (via USB-to-CAN adapter) |
| Chemometrics Software | Horizon MB, Quantify, PLSPlus, PLSIQ, Unscrambler |
| Brand | ABB |
|---|---|
| Origin | Canada |
| Model | MB3600-CH20 |
| Instrument Type | Laboratory FT-NIR Spectrometer |
| Principle | Fourier Transform Near-Infrared (FT-NIR) |
| Wavelength Range | 3800–14000 cm⁻¹ |
| Data Sampling Interval | < 0.7 cm⁻¹ |
| Measurement Mode | Transmission |
| Chemometrics Software | Horizon MB |
| Compliance | Designed for GLP/GMP-aligned workflows, supports ASTM E1655 and ISO 12099 data handling conventions |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MR304/170 |
| Instrument Type | Fourier Transform Infrared Spectrometer |
| Spectral Resolution | Adjustable up to 1 cm⁻¹ |
| Data Interface | 100 Mbps Ethernet |
| Scan Speed | ≥83 Hz (12 ms per interferogram) |
| Field of View Options | 5 mrad, 28 mrad, 75 mrad |
| NESR | <1.0 × 10⁻⁹ W·cm⁻²·sr⁻¹·cm |
| Compliance | ASTM E1421, ISO 18356, MIL-STD-461G (EMC), GLP/GMP-ready data audit trail |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Models | PIR3502, PFO3372, PUV3402 |
| Operating Principle | In-situ, Online & Portable |
| Spectral Ranges | UV (190–400 nm), VIS (400–700 nm), NIR (700–2500 nm), IR (2.5–25 µm) |
| Wavelength Channels | Up to 8 discrete optical bands |
| Integration | Compatible with VN2300 Analyzer Network |
| Sampling Interface | Direct path (PIR3502/PUV3402) and fiber-optic probe (PFO3372) |
| Brand | ABB |
|---|---|
| Origin | Canada |
| Model | MB-Rx |
| Instrument Type | In-situ, Real-time FTIR Spectrometer |
| Spectral Range | 600–8000 cm⁻¹ (configurable by probe/fiber combination) |
| Resolution | Adjustable from 1 cm⁻¹ to 64 cm⁻¹ (in 2 cm⁻¹ increments) |
| Scan Speed | Variable, dependent on resolution and scan count |
| Signal-to-Noise Ratio | 50,000:1 (60 s acquisition, 4 cm⁻¹ resolution) |
| Detector | Uncooled Room-Temperature Pyroelectric (DTGS) |
| ATR Probe Materials | Hastelloy® C-276, ZnSe, Diamond, ZrO₂ |
| Fiber Types | Silver Halide (AgClBr), Sulfide Glass |
| Spectral Digitization | 24-bit ADC |
| Detection Limit | 0.1% w/w acetone in toluene (60 s, 4 cm⁻¹) |
Show next