| Brand | ABB |
|---|---|
| Origin | Canada |
| Model | MBGAS-3000 |
| Instrument Type | Multi-component FTIR Flue Gas Analyzer |
| Measurement Principle | Fourier Transform Infrared Spectroscopy |
| Max. Simultaneous Components | 25 |
| Accuracy (Relative Error) | ≤4% FS |
| Repeatability | ≤2% RSD |
| Response Time (T90) | ≤80 s |
| Long-term Stability (7-day drift) | ≤4% FS |
| Operating Mode | Hot/Wet Sampling |
| Detection of Water-Soluble Gases | HCl, HF, NH₃, SO₂, NO, NO₂, CO, CO₂, CH₄, N₂O, etc. |
| Brand | ABB |
|---|---|
| Origin | Canada |
| Model | MBGAS-3000 |
| Instrument Type | Multi-component FTIR Flue Gas Analyzer |
| Measurement Principle | Fourier Transform Infrared Spectroscopy |
| Max. Simultaneous Components | 25 |
| Accuracy (Linearity & Span Error) | ≤ ±3% of full scale |
| Repeatability | ≤ 2% RSD |
| Response Time (T90) | ≤ 90 s |
| Long-term Stability (7-day drift) | ≤ 3% of full scale |
| Operating Mode | Hot/Wet Sampling |
| Optical Resolution | ≤ 0.5 cm⁻¹ |
| Laser Source Lifetime | ≥ 10 years |
| Compliance | Designed for EN 15267-3, EN 14181, ISO 12039, and US EPA Methods 320 & OTM-12 |
| Brand | ABB |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GLA133 |
| Detection Gases & Ranges | CH₄ (0–100 ppm standard |
| Response Time | 2.5 Hz (1/e) |
| Power Consumption | <35 W |
| Weight | <3 kg |
| Measurement Rate | Up to 10 Hz |
| Technology | Off-Axis Integrated Cavity Output Spectroscopy (OA-ICOS) |
| Brand | ABB |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GLA331-GGA |
| Price | Upon Request |
| Measured Gases & Ranges | CH₄ (0–100 ppm), CO₂ (0–20,000 ppm), H₂O (0–30,000 ppm) |
| Measurement Speed | Up to 10 Hz (GGA configuration) |
| CH₄ Precision (1σ, 1 s / 10 s / 100 s) | 0.6 ppb / 0.2 ppb / 0.1 ppb |
| CO₂ Precision (1σ, 1 s / 10 s / 100 s) | 150 ppb / 50 ppb / 20 ppb |
| H₂O Precision (1σ, 1 s / 10 s / 100 s) | 150 ppm / 50 ppm / 17 ppm |
| Maximum Drift (15-min avg, STP, 24 h) | CH₄ < 3 ppb, CO₂ < 0.2 ppm |
| Flow Response Time (1/e) | <10 s (standard), 0.1 s (with optional ACC-DS35 dry scroll pump) |
| Brand | ABB |
|---|---|
| Origin | Canada |
| Model | GLA351-N2OCM |
| Detection Gases & Ranges | N₂O (0–4 ppm, extended to 40 ppm), CO (0–4 ppm, extended to 40 ppm), H₂O (0–30,000 ppm, <99% RH, non-condensing) |
| Accuracy (1σ, 1 s / 10 s / 100 s) | N₂O: 0.1 / 0.04 / 0.02 ppb |
| CO | 0.2 / 0.06 / 0.03 ppb |
| H₂O | 50 / 20 / 10 ppm |
| Max Drift (24 h, STP, 15-min avg) | N₂O <1 ppb, CO <1 ppb |
| Measurement Rate | 0.01–1 Hz (standard), up to 10 Hz with high-flow option |
| Flow Response Time | <12 s (1/e), <10 s with high-flow option |
| Data Outputs | Ethernet, Wi-Fi, USB, RS-232 |
| Power | 110/240 VAC, 50/60 Hz |
| Dimensions | 50 × 48 × 86 cm (H×W×L) |
| Weight | 68 kg |
| Brand | ABB |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GLA132 |
| Price | Upon Request |
| Accuracy | < 1% uncertainty (uncalibrated, 5–45 °C) |
| Measured Gases & Ranges | CH₄ (0.01–100 ppm), CO₂ (200–20,000 ppm), NH₃ (1–10,000 ppb), H₂O (500–30,000 ppm) |
| Detection Principle | Fourth-Generation Cavity-Enhanced Absorption Spectroscopy (CEAS) |
| Power Consumption | < 70 W |
| Warm-up Time | < 2 min |
| Data Output Rate | 0.01–1 Hz (user-selectable) |
| Operating Temperature | 5–45 °C |
| Sample Temperature Range | −10–50 °C |
| Relative Humidity | 0–98% RH (non-condensing) |
| Dimensions | 47 × 35.6 × 17.8 cm (18.5″ × 14″ × 7″) |
| Weight | 17 kg |
| Compliance | CE, RoHS, FCC Class A |
| Data Storage | Internal Linux-based SSD with indefinite logging |
| Remote Access | Web-based GUI via Ethernet (HTTPS), full instrument control and diagnostics |
| Brand | ABB |
|---|---|
| Origin | Canada |
| Model | EL3000 |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Spectroscopy |
| Accuracy | ≤ 1% of full scale |
| CO₂ Measurement Range | 0–5 ppm to 95–100 vol% |
| Response Time (T₉₀) | 2.5 s |
| Repeatability | ≤ 0.5% of full scale |
| Brand | ABB |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GLA151-N2OCM |
| Price | Upon Request |
| Measured Gases & Ranges | Simultaneous N₂O and CO detection |
| Detection Limits (1σ, 10 sec) | N₂O ≤ 0.2 ppb, CO ≤ 0.2 ppb, H₂O ≤ 40 ppm |
| Linear Range | N₂O up to 4 ppm, CO up to 4 ppm, H₂O up to 30,000 ppm |
| Operating Temperature | 5–45 °C |
| Relative Humidity | <99% RH (non-condensing) |
| Measurement Rate | 0.01–10 Hz (user-selectable) |
| Flow Response Time | <30 s (1/e), <10 s (1/e) with ACC-DP3H external diaphragm pump |
| Water Vapor Correction | Real-time spectroscopic correction for dilution and pressure broadening effects |
| Brand | ABB |
|---|---|
| Origin | Canada |
| Model | GLA231 |
| Detection Gases | H₂O, NH₃, HCl, HF |
| Detection Range | Sub-ppb to % level (gas-dependent) |
| Output Options | 0–5 V DC, 4–20 mA, Modbus TCP (optional) |
| Operating System | Embedded Linux |
| Data Storage | Internal HDD with full spectral logging |
| Remote Access | Web-based GUI via Ethernet/IP |
| Calibration | Factory-certified, field-zero capable |
| Display | Integrated touchscreen interface |
| Security | Password-protected configuration and data access |
| Compliance | Designed for industrial process safety and AMC monitoring per SEMI F21, ISO 14644-8, and EPA Method TO-15 context |
| Brand | ABB |
|---|---|
| Origin | Canada |
| Model | Sensi+ |
| Detection Gases & Ranges | H₂S, H₂O, CO₂ in natural gas |
| Response Time | Simultaneous continuous monitoring |
| Technology Principle | Off-Axis Integrated Cavity Output Spectroscopy (OA-ICOS) |
| Application Field | Oil & Gas transmission and processing |
| Certifications | ATEX/IECEx Zone 1 certified |
| Installation | Wall-mounted, direct pipeline tap-in |
| Sample Flow Requirement | ~1/6 of conventional analyzers |
| Calibration | Factory-calibrated, zero maintenance calibration in field operation |
| Software Features | AnalyzerExpert™ with real-time interference compensation, laser beam lock, health monitoring, and self-diagnostics |
| Brand | ABB |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LGR |
| Price Range | USD 14,000 – 42,500 |
| Measurement Principle | Off-Axis Integrated Cavity Output Spectroscopy (OA-ICOS) |
| Target Analytes | Hydrogen Chloride (HCl), Hydrogen Fluoride (HF), Water Vapor (H₂O) |
| Detection Limits (1σ) | HF < 0.1 ppb (1 s), HCl < 0.4 ppb (1 s) |
| Response Time | < 2 s (with external N920 vacuum pump) |
| Measurement Range | HF: 0.3–20,000 ppb |
| HCl | 0.3–2,000 ppb |
| H₂O | 10–20,000 ppm (non-condensing) |
| Operating Range | HF: 0–10 ppm |
| HCl | 0–10 ppm |
| Stability | Ultra-low drift via proprietary temperature-controlled optical architecture |
| Data System | Embedded Linux computer with local storage, Ethernet/IP remote access, real-time spectral visualization |
| Compliance | Designed for EPA Method TO-15 / ASTM D6348-18 alignment |
| Brand | ABB |
|---|---|
| Origin | Canada |
| Model | GLA131-GGA |
| Detection Gases | CH₄ (0–100 ppm, optional 0–5%), CO₂ (0–20,000 ppm), H₂O (0–30,000 ppm) |
| Response Time | 3 s (1/e) |
| Warm-up to Data Logging | ≤20 s |
| Dimensions | 12 cm H × 34 cm W × 29.5 cm D |
| Weight (incl. battery) | <5.5 kg |
| Power Consumption | <35 W |
| Precision (1σ, 1s/10s/100s) | CH₄: 1 ppb / 0.4 ppb / 0.2 ppb |
| CO₂ | 0.4 ppm / 0.2 ppm / 0.1 ppm |
| H₂O | 200 ppm / 60 ppm / 30 ppm |
| Operating Temperature | 5–45 °C |
| Sample Temperature Range | −40–50 °C |
| Relative Humidity | 0–98% RH (non-condensing) |
| Data Output | SD card storage, Wi-Fi, USB, Ethernet, analog outputs |