| Brand | AGC |
|---|---|
| Origin | Ireland |
| Model | AGC100 Series |
| Instrument Type | Laboratory Gas Chromatograph |
| Application | High-Purity Gas Analysis |
| Oven Temperature Range | +5–450 °C |
| Oven Ramp Rate | 0.1–40 °C/min (0.1 °C increment) |
| Cooling Rate | 300–50 °C in ~5 min |
| Carrier Gas Flow Control Range | 0–500 mL/min |
| Carrier Gas Pressure Control Range | 0–700 kPa |
| Injector Max Temp | 450 °C |
| Injector Pressure Setting Range | 0–700 kPa |
| Injector Total Flow Setting Range | 10–500 mL/min |
| DID Operating Temp | 30–45 °C |
| Ambient Temp Requirement | 10–30 °C |
| Response Time (90%) | 0.5 s |
| Warm-up Time | 60 min |
| Display | 6.5″ color LCD with LED backlight and resistive touchscreen |
| Carrier Gas | Ultra-high-purity helium (He, N6.0), 20–60 mL/min |
| Sample Gas Flow | 10–500 mL/min (recommended: 200 mL/min) |
| Drive Gas | Clean, dry air at 300 kPa |
| Electronic Gas Control | Input 5–10 bar, output control 0–5 bar |
| Output Signal | 0–1 V analog |
| Communication | 4–20 mA, Profibus, Modbus RTU, RS-485 via TrendVision PLUS |
| Power Supply | 220 V AC |
| Dimensions (W×H×D) | 483 mm × 219 mm × 564 mm (19″ rack, 5U) |
| Weight | 25 kg |
| Brand | AGC |
|---|---|
| Origin | Ireland |
| Model | NovaCHROM 1000 DID |
| Instrument Type | Laboratory Gas Chromatograph |
| Application | Dedicated to High-Purity Hydrogen Analysis |
| Temperature Control Range | +5 °C to 450 °C |
| Oven Ramp Rate | 0.1–40 °C/min (0.1 °C increments) |
| Cool-down Time | ~5 min (300 °C to 50 °C) |
| Carrier Gas Flow Range & Control | 0–500 mL/min |
| Carrier Gas Pressure Range & Control | 0–700 kPa |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setpoint Range | 0–700 kPa |
| Injector Total Flow Setpoint Range | 10–500 mL/min |
| Detector | Helium Ionization Detector (DID) |
| DID Measurement Range | ppb to % level |
| DID Accuracy | ±1% of full-scale reading |
| DID Operating Temperature | 30–45 °C |
| Ambient Operating Temperature | 10–30 °C |
| DID Response Time (90%) | 0.5 s |
| DID Warm-up Time | 60 min |
| Display | 6.5″ color LCD with LED backlight and resistive touchscreen |
| Carrier Gas | Ultra-high-purity helium (He, N6.0), 20–60 mL/min |
| Sample Gas Flow | 10–500 mL/min (recommended: 200 mL/min) |
| Drive Gas | Clean, dry air at 300 kPa (3 bar) |
| Electronic Gas Control | 5–10 bar input → 0–5 bar regulated output |
| Standard Fittings | 1/8″ stainless steel Swagelok® and VCR |
| Output Signal | 0–1 V analog |
| Alarm Outputs | Detector, system, flow, maintenance, temperature, pressure |
| Data Interface | TrendVision PLUS with 4–20 mA, Profibus, Modbus, RS-485 |
| Power Supply | 220 V AC |
| Dimensions (W×H×D) | 483 mm × 219 mm × 564 mm (19″ rack, 5U) |
| Weight | 25 kg |
| Brand | AGC |
|---|---|
| Origin | Ireland |
| Model | NovaCHROM 1000 |
| Instrument Type | Online Gas Chromatograph |
| Application | High-Purity Gas Impurity Analysis |
| Oven Temperature Range | 4 °C to 450 °C |
| Temperature Stability | < ±0.05 °C/h (after 30 min warm-up) |
| Cooling Rate | 300 °C to 50 °C in ~5 min |
| Carrier Gas Flow Control Range | 0–500 mL/min |
| Carrier Gas Pressure Control Range | 0–900 kPa |
| Injector Max Temperature | 300 °C |
| Injector Pressure Setting Range | 0–700 kPa |
| Injector Total Flow Setting Range | 10–500 mL/min |
| Brand | AGC |
|---|---|
| Origin | Ireland |
| Model | AGC 600DID |
| Instrument Type | Laboratory Gas Chromatograph |
| Application | Ultra-High-Purity (UHP) Gas Analysis |
| Oven Temperature Range | 5°C above ambient to 450°C |
| Oven Ramp Rate | 0.1–40°C/min (0.1°C increments) |
| Oven Cool-Down | 300°C to 50°C in ≤5 min |
| Carrier Gas Flow Control Range | 0–500 mL/min |
| Carrier Gas Pressure Control Range | 0–900 kPa |
| Injector Maximum Temperature | 450°C |
| Injector Pressure Setting Range | 0–700 kPa |
| Injector Total Flow Setting Range | 10–500 mL/min |
| Brand | AGC |
|---|---|
| Origin | Ireland |
| Model | NovaCHROM1000 |
| Instrument Type | Online Gas Chromatograph |
| Application | High-Purity Gas Impurity Analysis |
| Oven Temperature Range | 4°C to 450°C |
| Temperature Stability | < ±0.05°C/h (after 30 min warm-up) |
| Cooling Rate | 300°C → 50°C in ~5 min |
| Carrier Gas Flow Control Range | 0–500 mL/min |
| Carrier Gas Pressure Control Range | 0–900 kPa |
| Injector Maximum Temperature | 300°C |
| Injector Pressure Setting Range | 0–700 kPa |
| Injector Total Flow Setting Range | 10–500 mL/min |
| Brand | AGC |
|---|---|
| Origin | Ireland |
| Model | AGC NovaCHROM2000 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | Universal for Ultra-High-Purity Gas Analysis |
| Temperature Control Range | 5°C above ambient to 450°C |
| Oven Ramp Rate | 0.1–40°C/min (0.1°C increment) |
| Cooling Rate | 1°C/sec (typical, from 450°C to 50°C) |
| Carrier Gas Flow Range & Control | 0–40 mL/min (EPC-controlled) |
| Carrier Gas Pressure Range & Control | 0–600 psi (EPC-controlled) |
| Injector Maximum Operating Temperature | 450°C |
| Injector Pressure Setting Range | 0–200 psi |
| Injector Total Flow Setting Range | 100–300 mL/min |
| Detector Options | ADD (Argon Discharge Detector), DID (Dielectric Barrier Discharge Ionization Detector), TCD, FID, FPD |
| Detection Limit | Sub-ppb to ppm level |
| Accuracy | ±1% of full scale |
| Response Time | 0.5 s (to 90% of final signal) |
| Warm-up Time | ≤60 min |
| Display | 6.5" color LCD with LED backlight and resistive touchscreen |
| Carrier Gas | Ultra-high-purity argon (Ar, N6.0, 99.9999% purity), flow 20–60 mL/min |
| Sample Gas Flow | 10–500 mL/min (recommended: 200 mL/min) |
| Drive Gas | Clean, dry air at 3 bar (300 kPa) |
| Electronic Pressure Control Input | 5–10 bar |
| Output Control Range | 0–5 bar |
| Standard Fittings | 1/8" stainless steel Swagelok® and VCR |
| Analog Output | 0–1 V (detector, system status, flow, maintenance, temperature, pressure) |
| Data Interface | TrendVision PLUS with 4–20 mA, Profibus, Modbus RTU, and RS-485 |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Dimensions (Rack Mount) | 19" (483 mm) W × 5U (219 mm) H × 22" (564 mm) D |
| Dimensions (Free-Standing) | H=900 mm, W=600 mm, D=400 mm |
| Weight | 25 kg |
| Brand | AGC |
|---|---|
| Origin | Ireland |
| Model | AGC NC1000 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application | Ultra-High-Purity Semiconductor Gas Analysis |
| Temperature Control Range | 0–300 °C |
| Ramp Rate | 0.1–40 °C/min (0.1 °C increment) |
| Cool-down Time | ~5 min (300 °C → 50 °C) |
| Carrier Gas Flow Range | 0–900 mL/min |
| Carrier Gas Pressure Range | 0–700 kPa |
| Injector Max Temp | 450 °C |
| Injector Pressure Setpoint Range | 0–700 kPa |
| Injector Total Flow Setpoint Range | 0–500 mL/min |
| Detector | Pulsed Helium Discharge Ionization Detector (DID) |
| Detection Range | ppb to % level |
| Accuracy | ±1% of full scale |
| Response Time (90%) | 0.5 s |
| Warm-up Time | 60 min |
| Display | 6.5″ color LCD with resistive touchscreen |
| Dimensions (W×H×D) | 483 mm × 219 mm × 564 mm (19″ rack-mount, 5U) |
| Weight | 25 kg |
| Carrier Gas | Ultra-high-purity helium (N6.0, 20–60 mL/min) |
| Sample Flow | 10–500 mL/min (recommended: 200 mL/min) |
| Drive Gas | Dry, oil-free air at 300 kPa |
| Electronic Pressure/Flow Control | 0–5 bar output (5–10 bar input) |
| Output Signals | 0–1 V analog |
| Compliance | Designed for ASTM D7527, ISO 8573-5, IEC 61511, and aligned with USP <621>, FDA 21 CFR Part 11 data integrity requirements for electronic records |
| Brand | AGC |
|---|---|
| Origin | Ireland |
| Model | AGC NP9000 |
| Instrument Type | Online Gas Chromatograph |
| Application | High-Purity Gas Analysis |
| Temperature Control Range | +5°C to 450°C |
| Oven Ramp Rate | 0.1–40°C/min (0.1°C increments) |
| Cooling Rate | 300°C to 50°C in ~5 min |
| Carrier Gas Flow Range & Control | 0–500 mL/min |
| Carrier Gas Pressure Range & Control | 0–700 kPa |
| Injector Max Operating Temperature | 450°C |
| Injector Pressure Setting Range | 0–700 kPa |
| Injector Total Flow Setting Range | 10–500 mL/min |
| Explosion Protection Rating | Ex pxb IIB+H2 T3 Gb |
| Column Oven Configuration | Multiple Independent Temperature-Controlled Ovens |
| Display | 12" Industrial Capacitive Touchscreen |
| Data Output Interfaces | 4–20 mA, Profibus, Modbus, Ethernet |
| Detector Options | DID, FID, TCD, FPD, PID, ADD |
| Column Types Supported | Packed, Micro-packed, Capillary |
| Valve Types | Stainless Steel / Hastelloy VICI Valco (4-, 6-, 8-, or 10-port) |
| Enclosure Material | Low-Carbon Steel with Front Safety Door |
| Gas Line Fittings | 1/8" Swagelok® or VCR (Hastelloy optional) |
| Operating Ambient Temperature | −10°C to +50°C |