BrandAGC
OriginIreland
ModelAGC100 Series
Instrument TypeLaboratory Gas Chromatograph
ApplicationHigh-Purity Gas Analysis
Oven Temperature Range+5–450 °C
Oven Ramp Rate0.1–40 °C/min (0.1 °C increment)
Cooling Rate300–50 °C in ~5 min
Carrier Gas Flow Control Range0–500 mL/min
Carrier Gas Pressure Control Range0–700 kPa
Injector Max Temp450 °C
Injector Pressure Setting Range0–700 kPa
Injector Total Flow Setting Range10–500 mL/min
DID Operating Temp30–45 °C
Ambient Temp Requirement10–30 °C
Response Time (90%)0.5 s
Warm-up Time60 min
Display6.5″ color LCD with LED backlight and resistive touchscreen
Carrier GasUltra-high-purity helium (He, N6.0), 20–60 mL/min
Sample Gas Flow10–500 mL/min (recommended: 200 mL/min)
Drive GasClean, dry air at 300 kPa
Electronic Gas ControlInput 5–10 bar, output control 0–5 bar
Output Signal0–1 V analog
Communication4–20 mA, Profibus, Modbus RTU, RS-485 via TrendVision PLUS
Power Supply220 V AC
Dimensions (W×H×D)483 mm × 219 mm × 564 mm (19″ rack, 5U)
Weight25 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAGC
OriginIreland
ModelNovaCHROM 1000 DID
Instrument TypeLaboratory Gas Chromatograph
ApplicationDedicated to High-Purity Hydrogen Analysis
Temperature Control Range+5 °C to 450 °C
Oven Ramp Rate0.1–40 °C/min (0.1 °C increments)
Cool-down Time~5 min (300 °C to 50 °C)
Carrier Gas Flow Range & Control0–500 mL/min
Carrier Gas Pressure Range & Control0–700 kPa
Injector Maximum Operating Temperature450 °C
Injector Pressure Setpoint Range0–700 kPa
Injector Total Flow Setpoint Range10–500 mL/min
DetectorHelium Ionization Detector (DID)
DID Measurement Rangeppb to % level
DID Accuracy±1% of full-scale reading
DID Operating Temperature30–45 °C
Ambient Operating Temperature10–30 °C
DID Response Time (90%)0.5 s
DID Warm-up Time60 min
Display6.5″ color LCD with LED backlight and resistive touchscreen
Carrier GasUltra-high-purity helium (He, N6.0), 20–60 mL/min
Sample Gas Flow10–500 mL/min (recommended: 200 mL/min)
Drive GasClean, dry air at 300 kPa (3 bar)
Electronic Gas Control5–10 bar input → 0–5 bar regulated output
Standard Fittings1/8″ stainless steel Swagelok® and VCR
Output Signal0–1 V analog
Alarm OutputsDetector, system, flow, maintenance, temperature, pressure
Data InterfaceTrendVision PLUS with 4–20 mA, Profibus, Modbus, RS-485
Power Supply220 V AC
Dimensions (W×H×D)483 mm × 219 mm × 564 mm (19″ rack, 5U)
Weight25 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAGC
OriginIreland
ModelNovaCHROM 1000
Instrument TypeOnline Gas Chromatograph
ApplicationHigh-Purity Gas Impurity Analysis
Oven Temperature Range4 °C to 450 °C
Temperature Stability< ±0.05 °C/h (after 30 min warm-up)
Cooling Rate300 °C to 50 °C in ~5 min
Carrier Gas Flow Control Range0–500 mL/min
Carrier Gas Pressure Control Range0–900 kPa
Injector Max Temperature300 °C
Injector Pressure Setting Range0–700 kPa
Injector Total Flow Setting Range10–500 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAGC
OriginIreland
ModelAGC 600DID
Instrument TypeLaboratory Gas Chromatograph
ApplicationUltra-High-Purity (UHP) Gas Analysis
Oven Temperature Range5°C above ambient to 450°C
Oven Ramp Rate0.1–40°C/min (0.1°C increments)
Oven Cool-Down300°C to 50°C in ≤5 min
Carrier Gas Flow Control Range0–500 mL/min
Carrier Gas Pressure Control Range0–900 kPa
Injector Maximum Temperature450°C
Injector Pressure Setting Range0–700 kPa
Injector Total Flow Setting Range10–500 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAGC
OriginIreland
ModelNovaCHROM1000
Instrument TypeOnline Gas Chromatograph
ApplicationHigh-Purity Gas Impurity Analysis
Oven Temperature Range4°C to 450°C
Temperature Stability< ±0.05°C/h (after 30 min warm-up)
Cooling Rate300°C → 50°C in ~5 min
Carrier Gas Flow Control Range0–500 mL/min
Carrier Gas Pressure Control Range0–900 kPa
Injector Maximum Temperature300°C
Injector Pressure Setting Range0–700 kPa
Injector Total Flow Setting Range10–500 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAGC
OriginIreland
ModelAGC NovaCHROM2000
Instrument TypeLaboratory Gas Chromatograph
Application ScopeUniversal for Ultra-High-Purity Gas Analysis
Temperature Control Range5°C above ambient to 450°C
Oven Ramp Rate0.1–40°C/min (0.1°C increment)
Cooling Rate1°C/sec (typical, from 450°C to 50°C)
Carrier Gas Flow Range & Control0–40 mL/min (EPC-controlled)
Carrier Gas Pressure Range & Control0–600 psi (EPC-controlled)
Injector Maximum Operating Temperature450°C
Injector Pressure Setting Range0–200 psi
Injector Total Flow Setting Range100–300 mL/min
Detector OptionsADD (Argon Discharge Detector), DID (Dielectric Barrier Discharge Ionization Detector), TCD, FID, FPD
Detection LimitSub-ppb to ppm level
Accuracy±1% of full scale
Response Time0.5 s (to 90% of final signal)
Warm-up Time≤60 min
Display6.5" color LCD with LED backlight and resistive touchscreen
Carrier GasUltra-high-purity argon (Ar, N6.0, 99.9999% purity), flow 20–60 mL/min
Sample Gas Flow10–500 mL/min (recommended: 200 mL/min)
Drive GasClean, dry air at 3 bar (300 kPa)
Electronic Pressure Control Input5–10 bar
Output Control Range0–5 bar
Standard Fittings1/8" stainless steel Swagelok® and VCR
Analog Output0–1 V (detector, system status, flow, maintenance, temperature, pressure)
Data InterfaceTrendVision PLUS with 4–20 mA, Profibus, Modbus RTU, and RS-485
Power Supply100–240 VAC, 50/60 Hz
Dimensions (Rack Mount)19" (483 mm) W × 5U (219 mm) H × 22" (564 mm) D
Dimensions (Free-Standing)H=900 mm, W=600 mm, D=400 mm
Weight25 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAGC
OriginIreland
ModelAGC NC1000
Instrument TypeLaboratory Gas Chromatograph
ApplicationUltra-High-Purity Semiconductor Gas Analysis
Temperature Control Range0–300 °C
Ramp Rate0.1–40 °C/min (0.1 °C increment)
Cool-down Time~5 min (300 °C → 50 °C)
Carrier Gas Flow Range0–900 mL/min
Carrier Gas Pressure Range0–700 kPa
Injector Max Temp450 °C
Injector Pressure Setpoint Range0–700 kPa
Injector Total Flow Setpoint Range0–500 mL/min
DetectorPulsed Helium Discharge Ionization Detector (DID)
Detection Rangeppb to % level
Accuracy±1% of full scale
Response Time (90%)0.5 s
Warm-up Time60 min
Display6.5″ color LCD with resistive touchscreen
Dimensions (W×H×D)483 mm × 219 mm × 564 mm (19″ rack-mount, 5U)
Weight25 kg
Carrier GasUltra-high-purity helium (N6.0, 20–60 mL/min)
Sample Flow10–500 mL/min (recommended: 200 mL/min)
Drive GasDry, oil-free air at 300 kPa
Electronic Pressure/Flow Control0–5 bar output (5–10 bar input)
Output Signals0–1 V analog
ComplianceDesigned for ASTM D7527, ISO 8573-5, IEC 61511, and aligned with USP <621>, FDA 21 CFR Part 11 data integrity requirements for electronic records
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAGC
OriginIreland
ModelAGC NP9000
Instrument TypeOnline Gas Chromatograph
ApplicationHigh-Purity Gas Analysis
Temperature Control Range+5°C to 450°C
Oven Ramp Rate0.1–40°C/min (0.1°C increments)
Cooling Rate300°C to 50°C in ~5 min
Carrier Gas Flow Range & Control0–500 mL/min
Carrier Gas Pressure Range & Control0–700 kPa
Injector Max Operating Temperature450°C
Injector Pressure Setting Range0–700 kPa
Injector Total Flow Setting Range10–500 mL/min
Explosion Protection RatingEx pxb IIB+H2 T3 Gb
Column Oven ConfigurationMultiple Independent Temperature-Controlled Ovens
Display12" Industrial Capacitive Touchscreen
Data Output Interfaces4–20 mA, Profibus, Modbus, Ethernet
Detector OptionsDID, FID, TCD, FPD, PID, ADD
Column Types SupportedPacked, Micro-packed, Capillary
Valve TypesStainless Steel / Hastelloy VICI Valco (4-, 6-, 8-, or 10-port)
Enclosure MaterialLow-Carbon Steel with Front Safety Door
Gas Line Fittings1/8" Swagelok® or VCR (Hastelloy optional)
Operating Ambient Temperature−10°C to +50°C