| Brand | AGC |
|---|---|
| Origin | Ireland |
| Model | NovaPRO9000 |
| Repeatability | ±0.1% |
| Detection Limit | 1 ppb |
| Detector Type | Helium Discharge Ionization Detector (DID) |
| Column Oven Temperature Range | Ambient to 450 °C with Independent Per-Column Thermal Control |
| Carrier Gas Requirement | Ultra-High-Purity Helium (99.999%) |
| Brand | AGC |
|---|---|
| Origin | Ireland |
| Model | AGC23 THC Analyzer |
| Detection Principle | Catalytic Combustion + Methane Conversion + Flame Ionization Detection (FID) |
| Display | 5.7″ QVGA Touchscreen |
| Calibration | Automated Zero/Range Calibration via Internal Solenoid Valves |
| Flow Control | Digital Electronic Mass Flow Controllers (MFCs) |
| Sample Flow Monitoring | Real-time Digital Flow Visualization & Alarm |
| Output Signals | 2 × Isolated, Passive 4–20 mA Outputs |
| Communication | RS-232 Serial Interface |
| Range Selection | 3 Auto-ranging Full-Scale Ranges |
| Compliance Support | Designed for ISO 8573-5, ASTM D6245, EPA Method 25A, and EN 15409-compliant installations |
| Safety Certification | ATEX / IECEx Zone 2 (optional), CE Marked |
| Brand | AGC |
|---|---|
| Origin | Ireland |
| Model | NovaSTREAM 6000 |
| Detection Principle | Flame Ionization Detection (FID) |
| Measurement Range | 0–20,000 ppm C₁–C₁₀ (as methane or propane equivalent) |
| Minimum Detectable Level | <10 ppb |
| Linearity Error | ≤±1% F.S. |
| Repeatability | ±30 ppb |
| Span Drift | ±30 ppb (24 h) |
| Response Time (T₉₀) | ≤30 s |
| Operating Temperature | 10–40 °C |
| Display | 6.5-inch TFT LCD touchscreen |
| Data Storage | 10,000 measurement records |
| Communication Interface | RS232 |
| Dimensions (W×H×D) | 483 mm × 450 mm × 400 mm (19″ rack-mount compatible) |
| Alarm Outputs | Dry-contact relays for high/low concentration, system fault, sample gas interruption, zero/span gas loss, and flame-out detection |
| Built-in Diagnostics | 20 standardized fault codes |
| Auto-Calibration | Motorized solenoid valves for automated zero/span calibration cycles |
| Flow Control | Integrated electronic mass flow controllers (MFCs) for sample, hydrogen, air, and zero/span gases |
| Brand | AGC |
|---|---|
| Origin | Ireland |
| Model | NovaSTREAM 6000 |
| Linear Error | ≤±1% F.S. |
| Repeatability | ≤±1% F.S. |
| Drift | ≤±1% F.S./6 months |
| Response Time | ≤5 s (T90) |
| Detection Limit | <10 ppb |
| Power Consumption | <100 W |
| Minimum Inlet Pressure | 10 kPa |
| Display | 6.5-inch color LCD touchscreen |
| Output Interfaces | 2 × 4–20 mA, 1 × mV, VGA, USB, Ethernet, RS-232, RS-485 |
| Data Storage | Up to 24 months internally |
| Calibration | Automated with audit-trail logging |
| Brand | AGC |
|---|---|
| Origin | Ireland |
| Model | AGC STREAM 6000 |
| Detection Principle | High-Frequency Argon Discharge Detector (HFADD) |
| Measurement Range | 0–1 ppm / 0–10 ppm / 0–100 ppm |
| LOD | 10 ppb |
| Accuracy | ±1% of full scale |
| Zero Drift | <1% FS / Span Drift: <1% FS |
| Response Time (t₉₀) | 5 s |
| Display | 6.5" industrial-grade touchscreen |
| Signal Outputs | 2 × 4–20 mA, 1 × mV, VGA, USB |
| Communication Options | RS-232 / RS-485 / Ethernet (optional) |
| Alarm Outputs | 7 dry-contact relays (including sample flow monitor) |
| Calibration | Auto-calibration with audit-trail logging |
| Data Storage | Internal non-volatile memory (24-month trend retention) |
| Sample Flow Rate | 5–200 mL/min |
| Inlet Pressure | 10–50 kPa |
| Power | 100–120 VAC / 220–240 VAC, 50/60 Hz |
| Dimensions | 482 mm (W) × 511 mm (D) × 177 mm (H), 4U 19″ rack-mountable |
| Weight | 9 kg |