BrandTAITEC
OriginJapan
ModelμT-12
Instrument TypeBead Mill Cell Disruptor
Operating Frequency53 Hz
Sample Capacity12 × 5.0 mL tubes
Throughput12 samples per run
Speed Range1,800–3,200 rpm (8-step digital adjustment)
Timer1–300 s (1-s increment, memory for 2 speed/time presets)
Safety FeaturesLid-interlock shutdown, overload current protection
Dimensions310 × 400 × 200 mm (W × D × H)
Weight~15 kg
Power SupplyAC 100 V, 4 A
Ambient Operating Range+5 °C to +35 °C
Tube CompatibilityStandard threaded 1.5/2.0 mL and 5.0 mL microtubes (e.g., Watson 1392-200, 2332-105)
Bead CompatibilityStainless steel (SUS), zirconia, glass beads
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTAITEC
OriginJapan
ModelVP-050N / VP-300N
Output Power50 W (VP-050N), 300 W (VP-300N)
Frequency Range19.5–20.5 kHz (VP-050N), 19–21 kHz (VP-300N)
Transducer InterfaceIntegrated horn-type piezoelectric converter with auto-tuning
ControlDigital LCD interface with real-time % output, current, temperature (*optional sensor), timer (1 s–120 min), and pulse mode (ON/OFF: 0.1–60 s)
Probe OptionsΦ2 mm, Φ3 mm, Φ6 mm stepped microprobes (VP-050N)
Dimensions (W×D×H)122×288×283 mm (VP-050N), 143×360×283 mm (VP-300N)
Weight4.5 kg (VP-050N), 6.7 kg (VP-300N)
Power SupplyAC 100 V, 1 A (VP-050N), AC 100 V, 5 A (VP-300N)
ComplianceDesigned for GLP-compliant lab environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTAITEC
OriginJapan
ModelμT-01
Disruption PrincipleHorizontal umbrella-shaped oscillation
Speed Range2,500–4,600 rpm (6 preset steps)
Sample Volume2 mL
Sample Capacity1 tube per run
Compatible BeadsGlass, zirconia, stainless steel beads (φ0.15–6 mm), metal mortars
Operating Temperature+5 to +35 °C
Vibration Frequency40–78 Hz
Timer Range5–60 s (6 presets)
Safety FeaturesLid interlock stop, overload current protection
Dimensions172 × 280 × 160 mm (W × D × H)
Weight~5 kg
Power SupplyAC 100 V, 0.5 A
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTAITEC
OriginJapan
ModelGM-01
Instrument TypeBead Mill Cell Disruptor
Temperature Range0 °C to 40 °C
Sample Volume2.0 mL per tube
ThroughputUp to 12 samples (6 with metal beads)
Maximum Centrifugal Force1300 × g
Speed Range500–4500 rpm
Vortex Mixing Intensity10 levels (Level 10 ≈ 2600 rpm equivalent shear)
Timer Range0–50 sec, or 1 min–99 h 50 min
Dimensions210 × 268 × 176 mm (W × D × H)
Weight~3.5 kg
Power SupplyAC 100–125 V, 0.5 A