- All
- Favorite
- Popular
- Most rated
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MG-1300M-2A |
| Price Range | USD 13,500–67,500 (est.) |
| Temperature Control Range & Accuracy | +5°C above ambient to +40°C |
| Temperature Uniformity | ±0.5°C (chamber) |
| Humidity Control | Not equipped |
| Capacity | Dual-stack configuration supporting two 40-layer multilayer cell culture vessels (e.g., CellMASSter, Cell Factory, CellSTACK) |
| Heating Method | Quadruple-wall air-jacketed + inline gas-stream heating |
| CO₂ Sensing & Control | NDIR infrared sensor |
| O₂ Sensing | Zirconia-based electrochemical sensor |
| Gas Flow Rate | 2 L/min × 2 independent channels |
| Air Circulation | Horizontal laminar flow fan |
| Data Logging | Integrated Windows XP-based PC with 6.5" touchscreen |
| Safety Features | Control board alarm (audible), high-temperature liquid-expansion safety device |
| Construction | Stainless steel interior and exterior |
| Dimensions (W×D×H) | 1280 × 950 × 1930 mm (excl. protrusions) |
| Standard Accessories | Two motorized rotating platforms for 40-layer vessels (incl. leveling mechanism and transport trolley), one shelf for 10-layer vessels |
| Compliance | Designed for GLP-compliant cell culture workflows |
| Brand | IRM |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | TE200 |
| Instrument Type | Tube Furnace |
| Maximum Temperature | 1200 °C / 1500 °C / 1700 °C (configurable by heating element & thermocouple) |
| Temperature Control Accuracy | ±1 °C |
| Max Power | 3 kW |
| Heating Time to Max Temp | 24 min |
| Heating Elements | High-quality resistance wire (1200 °C), imported SiC rods (1500 °C), or MoSi₂ rods (1700 °C) |
| Internal Chamber Dimensions | Ø50 mm × 600 mm |
| Control System | PID-based intelligent microprocessor controller |
| Tube Diameter | 60 mm |
| Display | 7-inch color LCD touchscreen |
| Programmable Profiles | 15 stored ramp-soak programs |
| Ramp Rate | Up to 20 °C/min |
| Uniformity Zone Length | 250 mm |
| Tube Material | High-purity quartz (standard) or alumina (optional) |
| Insulation | High-density ceramic fiber |
| Safety Protections | Over-temperature cutoff, over-current/over-voltage protection, thermocouple failure detection, earth leakage circuit breaker |
| Thermocouple Types | K-type (≤1200 °C), S-type (≤1500 °C), B-type (≤1700 °C) |
| Brand | IRM |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | G75 |
| Instrument Type | Vertical Sterilizer |
| Maximum Temperature | 141 °C |
| Maximum Pressure | 0.3 MPa |
| Chamber Dimensions | 400 mm × 583 mm (Ø × H) |
| External Dimensions | 630 mm × 680 mm × 900 mm (W × D × H) |
| Chamber Volume | 75 L |
| Control Interface | 7-inch color LCD touchscreen |
| Heating Element | Titanium alloy, 3.2 kW |
| Chamber Material | SUS304 stainless steel |
| Sealing Ring | High-performance imported silicone |
| Safety Certifications | Dual active/passive safety architecture, independent overpressure and overtemperature protection, door interlock with real-time lid closure monitoring, dry-run prevention (dual-level water level detection), automatic fault diagnostics for SSR, CPU, sensors, valves, and power circuits |
| Cooling System | iSpeed rapid cooling module (lid openable in ~6 minutes) |
| Exhaust Modes | Full exhaust, pulse exhaust, no exhaust |
| Drainage | Automatic wastewater discharge (to floor drain or optional collection tank) |
| Power Supply | AC 220 V, 3.3 kW |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | CB-40 with SM-05R |
| Instrument Type | Circulating Constant-Temperature Bath |
| Temperature Range | 0 °C to +70 °C |
| Temperature Stability | ±0.1 °C (when paired with Thermo Minder controller) |
| Bath Volume | 9 L |
| Circulation Mode | Internal & External |
| Cooling/Heating Function | Dual-mode (Refrigeration & Heating) |
| External Flow Rate | Up to 9 L/min |
| Reservoir Internal Dimensions | 130 × 85 × 145 mm (W × D × H) |
| External Dimensions | 130 × 164 × 315 mm (W × D × H) |
| Weight | ~5 kg |
| Power Supply | 100 V AC, 13 A |
| Cooling Capacity | ~75 W (~65 kcal/h) at 25 °C ambient, 50 Hz |
| Safety Features | Short-circuit breaker, thermal fuse, compressor overheat protection (shutdown at +40 °C), leakage-current safeguard |
| Accessories Included | Base plate, 10-mm nozzle, integrated power outlet (13 A) |
| Brand | IRM |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | NE100 |
| Instrument Type | Vertical |
| Maximum Temperature | 141 °C |
| Maximum Pressure | 0.3 MPa |
| Chamber Dimensions | Ø400 × 778 mm |
| External Dimensions | 630 × 680 × 1120 mm |
| Chamber Volume | 100 L |
| Brand | IRM |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | IP260 |
| Illumination Method | Shelf-Integrated LED Lighting |
| Light Source | High-Efficiency White LED |
| Spectral Range | Visible Spectrum (400–700 nm) |
| Temperature Range | 10–65°C (with illumination), 0–65°C (without illumination) |
| Temperature Fluctuation | ±0.3°C |
| Temperature Uniformity | ±1.0°C (at 20°C, same shelf) |
| Humidity Range | 30–95% RH |
| Photosynthetic Photon Flux Density (PPFD) | 0–500 µmol/m²/s |
| Chamber Volume | 305 L |
| External Dimensions (W×D×H) | 780 × 790 × 1600 mm |
| Brand | IRM |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | SS260 |
| Illumination Method | Shelf-Integrated LED Lighting |
| Light Source | High-Efficiency White LED |
| Spectral Range | Visible Spectrum (400–700 nm) |
| Temperature Range | 10–65°C (with illumination), 0–65°C (without illumination) |
| Temperature Fluctuation | ±0.3°C |
| Temperature Uniformity | ±1.0°C (at 20°C, same shelf) |
| Photosynthetic Photon Flux Density (PPFD) | 0–500 µmol/m²/s |
| Net Capacity | 305 L |
| External Dimensions (W×D×H) | 780 × 790 × 1600 mm |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | SDN-B / EXN-B |
| Instrument Type | Constant-Temperature Water Bath |
| Circulation | Internal Recirculation |
| Temperature Range | Ambient +5°C to +70°C |
| Temperature Stability | ±0.1–0.3°C (SDN-B), ±0.02–0.08°C (EXN-B) |
| Temperature Resolution | 0.1°C |
| Heating Power | 800 W |
| Internal Chamber Dimensions (with Insulating Tray B) | 230 × 350 × 140 mm (W×D×H) |
| Unit Dimensions (SDN-B/EXN-B only) | 230 × 109 × 215 mm |
| Weight | ~3 kg (unit only), ~6 kg (with Tray B) |
| Power Supply | AC 100 V, 8.5 A |
| Safety Features | Overheat Protection, Low-Water-Level Detection, Sensor Fault Monitoring, Thermal Cut-Out, Circuit Breaker |
| Compliance | Designed for GLP-compliant laboratory environments |
| Key | Brand: TAITEC |
|---|---|
| Origin | Japan |
| Model | CO2-BR Series |
| Temperature Range | +4°C to +50°C |
| Temp. Control Accuracy | ±0.3°C to ±1.0°C |
| Oscillation Mode | Reciprocating / Orbital Switchable |
| Speed Range | 20–200 rpm (CO2-BR-40LF), 25–250 rpm (CO2-BR-43FL-MR/MT), 25/50 mm (CO2-BR-180LF) |
| Amplitude | 10–40 mm (variable), 25 mm (fixed), 25/50 mm (switchable) |
| Timer Range | 0 min – 99 h 59 min |
| Gas Distribution Channels | Up to 12 branches |
| Compatible Vessels | Erlenmeyer flasks (125 mL–5 L), multiwell plates, culture bags (5–20 L) |
| Power Supply | AC 100 V ±9% / ±12% |
| Weight | 70–180 kg |
| Compliance | Designed for GLP-compliant cell culture workflows |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | uT-48 |
| Instrument Type | Cryogenic Ball Mill |
| Sample Compatibility | Frozen biological and hard materials (tissues, bone, teeth, polymers, rubber, asbestos) |
| Output Particle Size | < 0.01 mm |
| Oscillation Mode | Vertical reciprocating |
| Speed Range | 0–2500 rpm |
| Capacity | Up to 48 × 2.0 mL microcentrifuge tubes or 4 × stainless-steel heavy-duty vessels |
| Sample Load per Tube | 100–200 mg (microtubes), 1–2 g (stainless-steel vessels) |
| Timer | 1–999 s (digital display) |
| Temperature Monitoring | −196 °C to +50 °C (measured at tube holder base) |
| Safety Features | Lid interlock, rack mounting confirmation switch |
| Dimensions | 220 × 310 × 315 mm (W × D × H) |
| Weight | ~10 kg |
| Power Supply | AC 100 V |
| Brand | Taitec |
|---|---|
| Origin | Japan |
| Model | DTU-mini, CTU-mini |
| Temperature Range | 0°C to 105°C (CTU-mini) |
| Temperature Accuracy | ±0.2°C |
| Heating/Cooling Time | ≤15 min (to 105°C from ambient) |
| Dimensions | 128 × 215 × 190 mm (H×W×D) |
| Net Weight | 1.6 kg |
| Temperature Setting Resolution | 0.1°C |
| Control Method | Dual-mode Peltier (CTU-mini), Resistive Heating with Fan Cooling (DTU-mini) |
| Safety Features | Over-temperature/under-temperature protection, sensor fault detection, fuse, memory error monitoring, automatic shutdown on thermal anomaly |
| Brand | IRM |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | L75 |
| Instrument Type | Vertical |
| Maximum Temperature | 141 °C |
| Maximum Pressure | 0.3 MPa |
| Chamber Dimensions | Ø400 × 583 mm |
| External Dimensions | 630 × 680 × 900 mm |
| Chamber Volume | 75 L |
| Brand | IRM |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | IAL260 |
| Illumination Method | Shelf-Integrated LED Lighting |
| Light Source | High-Efficiency White LED |
| Spectral Range | Visible Spectrum (400–700 nm) |
| Temperature Range | 10–65°C (with illumination), 0–65°C (without illumination) |
| Temperature Fluctuation | ±0.3°C |
| Temperature Uniformity | ±1.0°C (at 20°C, within single shelf) |
| Photosynthetic Photon Flux Density (PPFD) | 0–500 µmol/m²/s |
| Chamber Capacity | 305 L |
| External Dimensions (W×D×H) | 780 × 790 × 1600 mm |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | ES-Direct-1 |
| Instrument Type | Magnetic Stirrer |
| Max. Stirring Volume | 5 L |
| Speed Range | 5–120 rpm |
| Temperature Control | None |
| Enclosure Rating | IPX4-equivalent moisture-resistant design |
| Operating Ambient | –10°C to +56°C at 100% RH (–10°C to +40°C at ≤80% RH) |
| Power Supply | AC 100 V, ≤1 A |
| Dimensions (W×D×H) | 180 × 180 × 60 mm |
| Weight | 3.4 kg |
| Compliance | Designed for ISO 13485-aligned bioprocessing environments |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | SDminiN |
| Bath Type | Immersion Circulating Water Bath |
| Temperature Range | Ambient +5°C to +80°C |
| Temperature Stability | ±0.1°C |
| Heating Power | 500 W |
| Internal Circulation | Jet-flow circulation |
| Control Method | Platinum RTD-based PID control |
| Temperature Resolution | 0.1°C |
| Display | Dual-mode digital display (setpoint / actual bath temperature) |
| Safety Features | Float-type dry-run protection, overcurrent circuit breaker, thermal cut-off, heater guard shield, error diagnostics (low water level, overtemperature, sensor fault) |
| Dimensions (Bath) | 190 × 83 × 147 mm (W×D×H) |
| Dimensions (Unit) | 220 × 127 × 235 mm (W×D×H) |
| Weight | ~3 kg |
| Power Supply | AC 100 V, 5.5 A |
| Standard Bath | Polyethylene C-type tank (45 mm depth) |
| Optional Accessory | Heat-resistant plastic lid PF-SDM |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | N2 Boy |
| Nitrogen Generation Principle | Hollow Fiber Membrane Separation (MEM) |
| Output Flow Rate | 4 L/min |
| Output Pressure Range | 0.15–0.3 MPa |
| Nitrogen Purity | 97% at 4 L/min (up to 99.9% at ≤2 L/min) |
| Dew Point | −30 °C |
| Dimensions | 280 × 390 × 434 mm (W × D × H) |
| Weight | Approx. 23 kg |
| Power Supply | AC 100 V, 6.5 A |
| Standard Accessory | Pisco-to-conical nozzle adapter × 1 |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model(s) | CTU-Neo, DTU-Neo |
| Temperature Range | 0°C to 105°C (CTU-Neo) |
| Temperature Accuracy | ±0.2°C |
| Temperature Ramp Time (25°C → 100°C) | ~20 min |
| Cooling/Heating Method | Thermoelectric (Peltier) |
| Display Resolution | 0.1°C |
| Power Supply | AC 100 V, 2 A |
| Dimensions | 210 × 268 × 175 mm (W × D × H) |
| Weight | ~4 kg (without blocks) |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | VA-250F / VA-500R / VA-800R |
| Cooling Temperature Range | –45°C to –75°C |
| Condensate Capacity (per cycle) | ~200 mL (VA-250F) to ~1000 mL (VA-500R/800R) |
| Cooling Method | Direct-immersion refrigerated bath with internal condenser coil |
| Power Supply | AC 100 V, 5–13 A |
| Weight | 35–82 kg |
| Compliance | Designed for GLP-compliant laboratory environments |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | EVR-034 / EVR-032 / EVR-104 |
| Oscillation Speed | 200–1600 rpm |
| Platform Capacity | 4 × 96-well plates or 4 × microtube fixtures |
| Power Supply | AC 100 V, 0.5 A |
| Operating Temperature Range | +5 °C to +40 °C |
| Dimensions (EVR-034) | 342 × 405 × 100 mm |
| Weight | ~10 kg |
| Safety Features | Fuse, motor overload protection, overvoltage protection |
| Compliance | Designed for 3Q qualification (IQ/OQ/PQ) in GLP/GMP environments |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Distributor Type | Authorized Distributor |
| Origin Category | Imported |
| Model Series | Shaker (LR, XR, Mix-VR, EVR, Wave-PR, SI, SI Slim, E-36, PR-12, NR-1 to NR-5100, SR-1/2DS/2DW, TS-10/20, SR-10, VIX-100) |
| Timing Range | 0–99 h 59 min |
| Oscillation Frequency | 5–2500 rpm |
| Oscillation Amplitude | 10–70 mm |
| Temperature Control | None |
| Platform Configuration | Single or dual-layer flat platforms |
| Brand | IRM |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | IPF260 |
| Illumination Method | Shelf-Integrated LED Arrays |
| Light Source | High-Efficiency RGBW LEDs |
| Spectral Range | 400–700 nm (PAR) |
| Temperature Range | 10–65°C (with illumination), 0–65°C (dark) |
| Temperature Fluctuation | ±0.3°C |
| Temperature Uniformity | ±1.0°C (at 20°C, within single shelf) |
| Photosynthetic Photon Flux Density (PPFD) | 0–500 µmol/m²/s |
| Net Volume | 305 L |
| External Dimensions (W×D×H) | 780 × 790 × 1600 mm |
| Control System | 7-inch capacitive touchscreen with iHACC™ precision climate algorithm |
| Optional Modules | Humidity control (30–95% RH), CO₂ regulation (0–5000 ppm), 4G IoT connectivity, programmable multi-segment cycles (1–30 steps), event-logged audit trail, USB data export, and optional thermal printer |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | ES-Direct-4 |
| Rotational Speed Range | 5–120 rpm |
| Number of Positions | 4 |
| Maximum Flask Capacity per Position | 2 L (compatible with 125 mL to 8 L bottles, including standard roller bottles) |
| Operating Environment | Up to 100% RH, −10°C to +56°C (at 100% RH) |
| Construction | Stainless steel top plate and housing |
| Dimensions (W×D×H) | 330 × 330 × 60 mm |
| Weight | Approx. 11 kg |
| Power Supply | AC 100 V, ≤1 A |
| Compliance | Designed for ISO 13485-aligned lab environments |
| Brand | IRM |
|---|---|
| Model | IPT260 |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Category | Domestic Equipment |
| Illumination Method | Shelf-Integrated LED Lighting |
| Light Source | High-Efficiency White LED Array |
| Spectral Range | Visible Spectrum (400–700 nm) |
| Temperature Range | 10–65°C (with illumination), 0–65°C (without illumination) |
| Temperature Fluctuation | ±0.3°C |
| Temperature Uniformity | ±1.0°C (at 20°C, same shelf) |
| Photosynthetic Photon Flux Density (PPFD) | 0–500 µmol/m²/s |
| Chamber Capacity | 305 L |
| External Dimensions (W×D×H) | 780 × 790 × 1600 mm |
| Control Interface | 7-inch Capacitive Touchscreen |
| Cooling System | Inverter-Driven Hermetic Compressor |
| Humidity Control | Optional (IPTH/IPTHC variants only) |
| CO₂ Control | Optional (0–5000 ppm, IPTHC variants only) |
| Connectivity | Optional 4G IoT Module (Remote Monitoring & Control via Android/Web) |
| Safety Protections | Dual Independent Over-Temperature Cut-off, Leak Current Protection, Water-Level Monitoring (Auto-Fill & Overflow Prevention), Compressor High-Pressure & Fan Overheat Protection, Door-Open Alarm, Power-Failure Recovery, Sensor Fault Detection |
| Airflow | Adjustable-Speed Forced Convection |
| Access Ports | Two Ø50 mm Pass-Through Ports (Left & Right) |
| Mobility | Heavy-Duty Braked Casters |
| Compliance | Designed for GLP-aligned operation |
| Brand | IRM |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | General-Purpose Ultrasonic Cleaner |
| Capacity Range | 1.3 L – 30 L |
| Ultrasonic Frequency | 33 kHz / 40 kHz |
| Ultrasonic Power Output | 50 W – 500 W |
| Power Adjustment | Yes |
| Heating Temperature Range | 0–80 °C (adjustable) |
| Timer Range | 1–99 min (adjustable) |
| Sound-Dampening Lid | Included |
| Drain Option | Manual or Automatic (models ≥6 L) |
Show next