Add to compare
BrandRtec
OriginSwitzerland
ModelBOR-3000
ApplicationFriction and Wear Testing
ComplianceASTM D3704, D2509, D2782, D2981, G77, G176
Max Load10,000 N
Max Speed5000 rpm
Temp RangeUp to 500 °C
Torque MeasurementIn-line high-resolution
Test ModesContinuous, Reciprocating, Stepped Load, Oscillatory
Sample MountingModular block holder for shafts, bearings, seals, rings, thrust/conical rollers
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRtec
OriginSwitzerland
ModelTTQ-1000
ApplicationTribological Evaluation of Cutting, Threading & Drilling Lubricants
Measurement PrincipleIn-situ Rotational Torque + Acoustic Emission + Electrical Contact Resistance + Environmental Temperature Monitoring
Sample TypesAluminum, Steel, and Other Machinable Metals
Test ModesAutomated Multi-position Tapping, Drilling, and Milling Simulation
Compliance ContextSupports ASTM D3702, ISO 20623, and GLP-aligned data integrity requirements
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRtec
OriginSwitzerland
ModelFBT-1000
Test TypesEP (Extreme Pressure) and Wear Testing
Temperature Range–40 °C to 200 °C (optional up to 400 °C)
Maximum Load12,000 N
Rotational SpeedUp to 1800 rpm
Real-time MonitoringTorque, Load, Temperature, Acoustic Emission, Friction Coefficient
ComplianceISO 12583, ASTM D2266, D2596, D2783, D4172, DIN 51350, BS EN ISO 20623, CEC L-45-A-99
Sample CompatibilityLubricating oils, greases, additives, solid lubricants
Data ResolutionSub-micron wear scar measurement via integrated 3D profilometry
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRtec
OriginSwitzerland
ModelFFT-M
ApplicationLubricity & Wear Evaluation of Diesel/Gasoline Fuels
Standards ComplianceASTM D6079, ISO 12156-1, SH/T 0765-2005
Frequency Range0.1–300 Hz
Stroke10 µm–4.0 mm
Load CapacityUp to 10 N or 300 N (configurable)
Temperature Range−40 °C to +500 °C
Humidity Control5–95% RH (closed-loop)
Ball DiameterStandard 6 mm (1.6–12.7 mm optional)
Disk Dimensions10 mm diameter × 3 mm thickness (custom sizes available)
Real-time Force FeedbackPiezoelectric load sensor
Friction & Wear OutputDynamic coefficient of friction, total wear scar depth, acoustic emission, in-situ film formation monitoring
Environmental ControlInert gas purge capability (N₂, Ar), programmable atmosphere management