Empowering Scientific Discovery

Anzhouyuan (Shanghai) Environmental Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBBE / bbe Moldaenke
OriginGermany
ManufacturerYes
Import StatusImported
ModelAOA
ApplicationReal-time online chlorophyll a and phytoplankton group quantification
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBBE Moldaenke
OriginGermany
ManufacturerBBE Moldaenke GmbH
Product TypeOnline Water Toxicity Analyzer
ModelFish Toximeter II
Operating Temperature Range5–28 °C
Test OrganismZebrafish (Danio rerio)
Detection PrincipleReal-time Video-Based Behavioral Analysis
Compliance BasisExtended Dynamic Daphnia Test (EDDT)-aligned methodology, aligned with ISO 10706:2000 (Water quality — Guidance on toxicity testing using fish), EU WFD (Water Framework Directive) monitoring principles
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBBE / bbe Moldaenke
OriginGermany
ManufacturerYes
Import StatusImported
ModelAlgae Torch
Measurement ParametersTotal Chlorophyll a (0–500 µg/L), Cyanobacterial Density, Turbidity (0–200 NTU), GPS Coordinates
Detection Time<20 s
Resolution0.1 µg/L (Chl-a)
LOD0.15 µg/L
Excitation Wavelengths470 nm, 526 nm, 610 nm
Weight1.3 kg
Dimensions (H × Ø)500 mm × 60 mm × 68 mm
Power SupplyInternal Rechargeable Battery (AC Adapter: 110/240 V, 50/60 Hz)
Operating Temperature0–35 °C
Storage Temperature0–50 °C
IP RatingIP68
Depth Rating10 m (standard), 100 m (optional version)
Data Storage2000 measurements
InterfaceUSB
Softwarebbe++ for Windows
Accessories10-m rope, telescopic pole, nylon backpack, underwater data cable extensions (10–30 m), sensor performance kits
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBBE Moldaenke
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Instrument TypeOnline Analyzer
Measurement PrinciplePotassium Permanganate Oxidation with ORP Endpoint Detection
Range0–8 mg/L and 0–20 mg/L (dual-range auto-switching)
Repeatability±3% of Full Scale (FS)
Accuracy≤±3% FS
Limit of Detection (LOD)0.4 mg/L
Resolution0.01 mg/L
Analysis Cycle Time60 minutes per sample
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBBE/bbe Moldaenke
OriginGermany
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported
ModelA-ToxII
Instrument TypeOnline
Test OrganismAlgae (Chlorella vulgaris, ISO 8692:2012 compliant)
Operating Temperature0–35 °C
Reagent Storage Temperature0–30 °C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBBE / bbe Moldaenke
OriginGermany
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product OriginImported
Modelbbe TN—PWR II
Instrument TypeOnline Water Quality Analyzer
Measured ParameterTotal Nitrogen (TN)
Measurement PrincipleAlkaline Potassium Persulfate Digestion + UV-Vis Spectrophotometry
Measurement Range0–2.5 / 10 / 50 / 350 mg/L TN (selectable)
Accuracy≤ ±3% FS or ±0.05 mg/L (whichever is greater)
Repeatability≤2% RSD
Detection Limit0.05 mg/L (at lowest range)
Zero Drift≤3% FS/24 h
Span Drift≤3% FS/24 h
Measurement Cycle Time21 minutes
Resolution0.01 mg/L (at lowest range)
Dimensions (H×L×W)1190 × 600 × 310 mm
Weight~45 kg
Sample RequirementsOil-free, low-suspended solids
Temp.2–40 °C
Pressure0–0.1 bar
Flow Rate1.5–3.0 L/min
Output Interfaces4–20 mA analog output, RS232/RS485 serial communication
Protocol SupportMODBUS RTU/TCP (optional), TCP/IP (optional)
Key FeaturesFull-spectrum UV-Vis detection (220 nm, 275 nm, 400 nm, 700 nm), turbidity interference correction, integrated UV-assisted digestion, automatic calibration & cleaning, touchscreen HMI, remote status monitoring & QC verification (optional), power-fail recovery
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBBE / bbe Moldaenke
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Instrument TypeOnline Analyzer
Measurement PrinciplePotassium Dichromate Digestion Method (Online)
Wavelength600 nm (standard for Cr(VI)/Cr(III) absorbance ratio)
Measurement Range10–500 mg/L, 10–1000 mg/L, or 10–1500 mg/L (user-selectable range switching)
Accuracy≤ ±10% of reading
Repeatability≤ ±5% RSD
Limit of Detection (LOD)10 mg/L COD
Cycle Time30 minutes per analysis
Sample Volume per Cycle1.5–3 L
ComplianceDesigned to meet ISO 6060 and EPA Method 410.4 requirements for online COD monitoring
Added to wishlistRemoved from wishlist 0
Add to compare
Brandbbe Moldaenke
OriginGermany
Manufacturerbbe Moldaenke GmbH
Country of OriginImported
ModelPS
Instrument TypeOnline
Biological TargetAlgae
Operating Temperature0–40 °C
Reagent Storage Temperature0–40 °C
Sample Volume per Cycle45 mL
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBBE/bbe Moldaenke
OriginShanghai, China
Manufacturer TypeManufacturer
Product CategoryDomestic
ModelBG00750003
Instrument TypeBenchtop
AnalyteChloride Ion
Measurement Range0.1 mg/L
Limit of Detection (LOD)0.8 mg/L
Response Time10 min
Measurement Accuracy≤2%
Operating Temperature Range0–45 °C
Communication Interfaces4–20 mA, RS232/RS485, MODBUS RTU/TCP, TCP/IP (optional)
Added to wishlistRemoved from wishlist 0
Add to compare
Brandbbe Moldaenke
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryDomestic
Modelbbe TP+TN+NH4—PWR II
Instrument TypeOnline Water Quality Analyzer
Measured ParametersTotal Phosphorus (TP), Total Nitrogen (TN), Ammonia-Nitrogen (NH₄–N)
Measurement PrinciplesTN – Alkaline Potassium Persulfate Digestion + UV Spectrophotometry
Measurement RangesTN: 0–2.5 / 10 / 50 / 350 mg/L
TP0–2 / 5 / 10 / 100 mg/L
NH₄–N0–0.5 / 2 / 4 / 20 / 100 mg/L
AccuracyTN: ≤ ±3% FS or 0.05 mg/L (whichever greater)
TP≤ ±3% FS
NH₄–N≤ ±3% FS or 0.015 mg/L (whichever greater)
Repeatability≤2% for all parameters
Detection LimitsTN: 0.05 mg/L
TP0.0035 mg/L
NH₄–N0.0027 mg/L
Zero DriftTN: ≤3% FS/24h
TP & NH₄–N≤1% FS/24h
Span DriftTN: ≤3% FS/24h
TP & NH₄–N≤2% FS/24h
Measurement Cycle TimeTN: 21 min
TP30 min
NH₄–N8.4 min
ResolutionTN: 0.01 mg/L (min range)
TP0.001 mg/L (min range)
NH₄–N0.0001 mg/L (min range)
Dimensions (H×L×W)1190 × 600 × 310 mm
Weight~45 kg
Sample RequirementsOil-free, low-suspended solids
Temp2–40 °C
Pressure0.0–0.1 bar
Flow Rate1.5–3.0 L/min
Key TechnologiesDiode Array Full-Spectrum Detection (UV–Vis), Turbidity Interference Compensation, UV-Assisted Digestion, Modular Architecture, Touchscreen HMI, Remote Status Monitoring (optional), QC Check & Audit Trail Support (optional), Communication: 4–20 mA, RS232/RS485, MODBUS TCP/IP (optional)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBBE Moldaenke
OriginGermany
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported
ModelColifast CALM
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBBE Moldaenke
OriginGermany
ManufacturerBBE Moldaenke GmbH
TypeLaboratory Instrument
ModelPhycoLA
Operating Temperature0–40 °C
Reagent Storage Temperature0–40 °C
Sample Volume per Batch25 mL
Biological TargetCyanobacteria and Algal Taxa
Application DomainFreshwater and Brackish Water Quality Monitoring
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBBE Moldaenke
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Regional ClassificationDomestic (China)
ModelColifast Field Kit
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBBE Moldaenke
OriginGermany
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Instrument
ModelTC
Instrument TypeAlgal Cell Counter
Detection PrincipleIn Vivo Chlorophyll-a Fluorescence Analysis
Measurement Range0–20,000 cells/mL
Resolution1 cell/mL
Weight2.5 kg
Dimensions (H×W×D)258 × 243 × 117 mm
Power Supply100–240 V AC, 50/60 Hz
Protection RatingIP54 (lid closed), IP22 (lid open)
InterfaceUSB
Sample Temperature Range5–55 °C
Ambient Operating Temperature5–35 °C
Data Storage Capacity>100,000 measurements
Storage Temperature5–45 °C
Accessories IncludedUser Manual, 50 µm Filter, Power Adapter, 50-Filter Kit
Optional Accessory50-Filter Kit
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBBE / bbe Moldaenke
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Country of OriginChina
ModelBG00750001
Instrument TypeOnline Volatile Phenol Analyzer
Output Interfaces4–20 mA, RS232/RS485, MODBUS RTU/TCP, Ethernet (optional)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBBE / bbe Moldaenke
OriginGermany
Manufacturer TypeDirect Manufacturer
Import StatusImported
ModelTox protectII
Instrument TypeOnline Monitoring System
Test OrganismLive Fish (e.g., Danio rerio or Oncorhynchus mykiss)
Operating Temperature Range5–28 °C
Measurement Chamber Volume9 L (customizable)
Detection PrincipleReal-time optical grating-based behavioral activity monitoring
Communication InterfacesRS-485, Ethernet, Modbus TCP, optional GSM/SMS and analog alarm outputs
Alarm ModesLocal visual (tricolor LED), audible, remote SMS/fax/email via integrated gateway
ComplianceDesigned for GLP-aligned operation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBBE Moldaenke
OriginGermany
ManufacturerYes
Import StatusImported
ModelBG00430000
Measurement ParametersTotal chlorophyll a / total algal density
Measurement Range0–500 µg chl-a/L
Resolution0.01 µg chl-a/L
Detection Limit0.05 µg chl-a/L
Light Transmission Range0–100%
Excitation Wavelengths370, 470, 525, 570, 590, 610 nm
Measurement Time≤3 min per sample
Sample Volume25 mL
Operating Temperature0–35 °C
Storage Temperature0–50 °C
Dimensions (H×W×D)185 × 330 × 350 mm
Weight7.5 kg
Power Supply110/240 V AC, 50/60 Hz or 12 V DC
Power Consumption10 W
Protection RatingIP54
Data InterfaceRS232
Softwarebbe++ (Windows-based database software)
Optional AccessoriesPhotosynthetic activity module
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBBE / bbe Moldaenke
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryDomestic
Instrument TypeOnline Water Quality Analyzer
Measured ParametersTotal Nitrogen (TN), Total Phosphorus (TP)
Measurement Principle (TN)Alkaline Potassium Persulfate Digestion + UV-Vis Spectrophotometry
Measurement Principle (TP)Acidic Potassium Persulfate Digestion + Ammonium Molybdate Spectrophotometry
Detection Range (TN)0–2.5 / 10 / 50 / 350 mg/L
Detection Range (TP)0–2 / 5 / 10 / 100 mg/L
Accuracy (TN)≤ ±3% FS or 0.05 mg/L (whichever is greater)
Accuracy (TP)≤ ±3% FS
Repeatability≤2% for both TN and TP
LOD (TN)0.05 mg/L
LOD (TP)0.0035 mg/L
Zero Drift (TN)≤3% FS/24h
Zero Drift (TP)≤1% FS/24h
Span Drift (TN)≤3% FS/24h
Span Drift (TP)≤2% FS/24h
Measurement Cycle (TN)21 min
Measurement Cycle (TP)30 min
Resolution0.01 mg/L (at minimum range)
Dimensions (H×L×W)1190 × 600 × 310 mm
Weight~45 kg
Sample RequirementsOil-free, low-suspended solids
Temp.2–40 °C
Pressure0.0–0.1 bar
Flow Rate1.5–3.0 L/min
Output Interfaces4–20 mA analog, RS232/RS485 serial
Communication ProtocolsMODBUS RTU/TCP (optional), TCP/IP (optional)
Key HardwareDiode Array Spectrometer (UV–Vis, 190–800 nm), Integrated UV-Assisted Digestion Module
CalibrationAutomatic & Manual
MaintenanceModular Design with Tool-Free Access
DisplayTouchscreen HMI (Human-Machine Interface)
Data Integrity FeaturesAudit Trail Ready, QC Check & Verification Logging (optional), Remote Status Monitoring (optional)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBBE Moldaenke
OriginGermany
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported
ModelBenthoTorch 10
Detection PrincipleIn-situ chlorophyll-a fluorescence excitation & spectral signature analysis (405 nm LED excitation, 600–800 nm emission detection)
Measurement Time<20 s per measurement
Power SupplyRechargeable Li-ion battery (up to 8 h continuous operation)
Weight320 g
GPS ModuleIntegrated high-accuracy GNSS receiver (supports WGS84 coordinates, ±2 m CEP)
Data OutputCSV, KML, TXT
CalibrationAutomatic substrate compensation algorithm (patented optical baseline correction)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBBE Moldaenke
OriginGermany
ManufacturerYes
Import StatusImported
ModelColifast ALARM
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBBE / bbe Moldaenke
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Instrument CategoryDomestic (China-Made)
Modelbbe NH4—PWR II
Instrument TypeOnline Water Quality Analyzer
Measured ParameterAmmonia-Nitrogen (NH₃-N)
Measurement PrincipleSalicylate Spectrophotometry
Detection Range0–0.5 / 2 / 4 / 20 / 100 mg/L NH₃-N (selectable)
Accuracy≤ ±3% FS or 0.0014 mg/L (whichever is greater)
Repeatability≤2%
Limit of Detection (LOD)0.0027 mg/L (at 0–0.5 mg/L range)
Zero Drift≤1% FS/24 h
Span Drift≤2% FS/24 h
Measurement Cycle Time500 s
Resolution0.0001 mg/L (at 0–0.5 mg/L range)
Dimensions (H×L×W)1100 × 600 × 310 mm
Weight~45 kg
Sample RequirementsOil-free, low-suspended solids
Temp2–40 °C
Pressure0.0–0.1 bar
Flow Rate1.5–3.0 L/min
Output Interfaces4–20 mA analog, RS232/RS485 serial
Communication ProtocolsMODBUS RTU/TCP (optional), TCP/IP (optional)
CalibrationAutomatic & manual
MaintenanceModular design with tool-free access
DisplayIntegrated touchscreen HMI
Data Integrity FeaturesBuilt-in QC check verification, remote status monitoring (optional)
Environmental ComplianceDesigned for continuous operation in Class I, Division 2 hazardous locations per IEC 60079-0 (general requirements)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBBE Moldaenke
OriginGermany
ManufacturerBBE Moldaenke GmbH
Country of OriginImported
ModelDFP
PortabilityPortable
Target OrganismCyanobacteria (Phytoplankton)
Operating Temperature Range−2 °C to 40 °C
Reagent Storage Temperature−2 °C to 40 °C
Measurement Cycle Time7 hours
Depth Range0–100 m
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBBE / bbe Moldaenke
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Product OriginDomestic (China)
Modelbbe Phenol—PWR II
Instrument TypeOnline Water Quality Analyzer
AnalyteVolatile Phenol
Measurement Range0–0.1 / 2 / 20 mg/L (selectable)
Detection Limit0.001 mg/L (at lowest range)
Accuracy≤ ±3% FS or 0.0008 mg/L (whichever is greater)
Repeatability≤3%
Zero Drift≤2% FS/24h
Span Drift≤2% FS/24h
Measurement Cycle Time39 minutes
Resolution0.0001 mg/L (at lowest range)
Dimensions (H×L×W)1100 × 600 × 310 mm
Weight~45 kg
Sample RequirementsOil-free and particle-free
Temperature2–40 °C
Pressure0.0–0.1 bar
Flow Rate1.5–3.0 L/min
Output Interfaces4–20 mA, RS232/RS485
Communication ProtocolsMODBUS RTU/TCP (optional), TCP/IP (optional)
CalibrationAutomatic & manual
CleaningFully automated
Compliance FeaturesBuilt-in QC verification, remote operational status monitoring (optional)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBBE Moldaenke
OriginGermany
ManufacturerBBE Moldaenke GmbH
TypeImported
ModelTS
ApplicationField-deployable chlorophyll a and algal class quantification
Measurement PrincipleMulti-wavelength excitation fluorescence spectroscopy
Detection DepthUp to 1000 m (optional)
Key ParametersTotal chlorophyll a (0–500 µg/L, resolution 0.01 µg/L, LOD 0.05 µg/L), yellow substance (CDOM), green algae, cyanobacteria, diatoms/dinoflagellates, cryptophytes, depth (0–100/200/1000 m), temperature (−2 to 40 °C), transmittance (0–100%), pressure sensor integrated
Power12 V DC, internal rechargeable battery
HousingReinforced carbon fiber / V4A stainless steel (6.4 kg standard, 7.2 kg with housing, 5.1 kg titanium option)
Dimensions450 mm × 140 mm (H × Φ)
Memory2 GB (≥1000 datasets)
InterfaceRS485
Maintenance Interval≥7 days
Optional AccessoriesDesktop mount, temperature probe, wiper unit, protective housing, cable reel, auto-start plug, Bluetooth handheld interface, transport case, cables (3/10/20/30/50/100 m)