Add to compare
BrandAPL
OriginSichuan, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelAPL-AGS-36
Instrument TypeGas Chromatography Autosampler
Max Sample Capacity132 positions
Minimum Injection Volume1 mL
Quantitative Loop Volume1 mL
Sample Tray Configuration36-position base (expandable in 12-position modules)
Compatible Sampling DevicesGas-tight syringes and Tedlar®/aluminized gas bags
Tubing MaterialPTFE
Valve BodyPEEK
Valve CorePolyimide (PI)
Carrier Gas Line Purge Flow RateUp to 0.5 L/min
Injection PrecisionR² ≥ 0.9999 for total hydrocarbons and methane peak areas across five replicate injections
Dimensions (L×W×H)450 × 500 × 430 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAPL
OriginSichuan, China
Manufacturer TypeDirect Manufacturer
Region CategoryDomestic (China)
ModelDK-400
Instrument TypeStatic Headspace Sampler
Automation LevelManual Operation
Vial Heating RangeAmbient to 250 °C
Valve & Transfer Line Temperature Control RangeAmbient to 220 °C
Sample Loop Volume1.0 mL
Vial Capacity9 positions
Vial Size40 mL
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAPL
OriginSichuan, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelAPL-TD-50D
Instrument TypeTwo-Stage Thermal Desorber / Thermal Desorption Unit
Automation LevelFully Automated
Desorption Temperature Range–35 °C to 400 °C
Valve Injection Zone Temperature RangeAmbient to 300 °C
Transfer Line Temperature RangeAmbient to 300 °C
Cold Trap Temperature Range–35 °C
Temperature Control Accuracy±1 °C
Analyte Recovery Rate>98%
Sample Capacity50 Adsorption Tubes
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAPL
OriginSichuan, China
Manufacturer TypeDirect Manufacturer
Regional ClassificationDomestic (China)
ModelHS-Auto126
Instrument TypeStatic Headspace Sampler
Automation LevelFully Automatic
Sample Vial Heating RangeAmbient to 280 °C
Valve Temperature Control RangeAmbient to 280 °C
Sample Loop Volume1 mL / 2 mL
Temperature Control Accuracy±0.1 °C
Sample Capacity126 positions
Vial Format20 mL standard (10 mL optional)
Sample Zone Heating RangeAmbient to 260 °C
Valve & Transfer Line Heating RangeAmbient to 220 °C
PrecisionRSD ≤1% (200 ppm ethanol in water, n=5)
Pressurization Range0–0.4 MPa (adjustable)
Purge Flow Rate0–100 mL/min (adjustable)
Vial Heating Positions15
Oscillation ModeVertical wave-like agitation during equilibration
Display7-inch capacitive touchscreen
Method StoragePreloaded compliance methods (e.g., EPA 502.2, USP <467>, ISO 11843-3)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAPL
OriginSichuan, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryDomestic
ModelHS-12
Instrument TypeStatic Headspace Sampler
Automation LevelSemi-Automatic
Sample Vial Heating RangeAmbient to 250 °C
Valve Temperature Control RangeAmbient to 220 °C
Loop Volume2 mL
Vial Capacity12 positions
Vial Size20 mL
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAPL
OriginSichuan, China
Manufacturer TypeManufacturer
Origin CategoryDomestic
ModelAPL-PT-100
Sample Capacity100 positions
Injection PrecisionRSD < 3%
Trap Temperature Range−30 °C to 400 °C
Purge Sample Heating TemperatureAmbient to 120 °C
Sample Vial Cooling Temperature−30 °C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAPL
OriginSichuan, China
Manufacturer TypeDirect Manufacturer
Origin CategoryDomestic (China)
ModelHS-45
Instrument TypeStatic Headspace Sampler
Automation LevelFully Automated
Vial Heating RangeAmbient to 260 °C (1 °C increments)
Valve Temperature Control RangeAmbient to 240 °C (1 °C increments)
Sample Loop Volume1 mL
Temperature Control Accuracy±0.1 °C
Vial Capacity45 positions
Compatible Vial Sizes10 mL and 20 mL
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAPL
OriginSichuan, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryDomestic
ModelAPL-PTC100
Instrument TypeWater & Soil VOC Analysis System
Sample Tray Capacity1 position
Injection PrecisionRSD < 3%
Trap Temperature Range–30 °C to 220 °C
Sample Heating Temperature RangeAmbient to 220 °C
Sample Vial Cooling Temperature20 °C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAPL
OriginSichuan, China
Manufacturer TypeDirect Manufacturer
Instrument TypeLaboratory Gas Chromatograph
ModelAPL-GC-901A
Temperature Control RangeAmbient +4°C to 450°C
Maximum Ramp Rate80°C/min
Cooling Time<7 min (250°C to 50°C)
Carrier Gas Flow Range0–500 mL/min
Carrier Gas Pressure Range0–0.6 MPa
Injector Maximum Temperature350°C
Injector Pressure Setting Range0–0.4 MPa
Total Injector Flow Setting Range0–1000 mL/min
Temperature Zones8 independently controlled zones
Programmed Temperature RampingUp to 16 steps
Ramp Rate Adjustable0.1–60°C/min
Temperature Stability±0.1°C
Display7-inch capacitive touchscreen LCD
Detector CompatibilityFID, TCD, ECD, FPD, NPD (up to 3 simultaneously installed)
Injection OptionsPacked column, capillary column, dual-capillary, valve-based gas injection, headspace, thermal desorption, autosampler-ready
Column Oven Dimensions260 × 270 × 235 mm
Communication InterfaceEthernet (IEEE 802.3)
External Events8 inputs, 2 auxiliary outputs
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAPL
OriginSichuan, China
Manufacturer TypeDirect Manufacturer
Instrument TypeStatic Headspace Sampler
Automation LevelFully Automated
Sample Tray Capacity20 positions
Vial Size20 mL (standard), 10 mL (optional)
Oven Temperature RangeAmbient to 260 °C
Valve & Transfer Line Temperature RangeAmbient to 220 °C
Loop Volume1 mL
Pressure Control Range0–0.4 MPa (adjustable)
Purge Flow Rate0–400 mL/min (adjustable)
Temperature Stability< ±0.1 °C
PrecisionRSD ≤ 1% (200 ppm ethanol in water, n = 5)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAPL
OriginSichuan, China
Manufacturer TypeDirect Manufacturer
Instrument TypeStatic Headspace Sampler
Automation LevelFully Automated
Sample Tray Capacity80 positions
Vial Sizes Supported10 mL and 20 mL
Oven Temperature RangeAmbient to 260 °C (1 °C increments)
Valve Temperature RangeAmbient to 240 °C (1 °C increments)
Loop Volume1 mL
Temperature Control Accuracy±0.1 °C
Independent Heated ZonesSample oven, injection valve, transfer line, and needle
AgitationAdjustable speed, integrated into each of 15 heated positions
System PurgeAutomatic inert gas flush after each injection
Leak DetectionReal-time vial presence verification
Software Interface7-inch touchscreen with bilingual (English/Chinese) UI, method storage, real-time GC status display (carrier gas & pressurization pressure), AFM-based flow monitoring
Compliance SupportDesigned for GLP/GMP environments with audit-ready method logging, event timestamping, and system self-test at power-on
Mechanical ArchitectureDual three-axis rotary gantry for precise vial handling, piercing, sampling, and injection
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAPL
OriginSichuan, China
Manufacturer TypeDirect Manufacturer
Instrument TypeStatic Headspace Sampler
Automation LevelFully Automated
Sample Tray Capacity60 positions (15 heated positions)
Backup Positions20
Vial Size Compatibility10 mL and 20 mL (standard)
Oven Temperature RangeAmbient to 260 °C (1 °C increment)
Valve & Transfer Line Temperature RangeAmbient to 220 °C (1 °C increment)
Temperature Accuracy±0.1 °C
Pressure-Controlled Injection0–0.4 MPa (adjustable)
Purge Flow Rate0–400 mL/min (adjustable)
PrecisionRSD ≤1% (200 ppm ethanol in water, n=5)
Injection Volume ControlPressurization time + regulated pressure
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAPL
OriginSichuan, China
Manufacturer TypeDirect Manufacturer
Instrument TypeDual-Stage Thermal Desorber
Automation LevelFully Automated
Desorption Temperature RangeAmbient to 400 °C
Valve & Injection Port Temperature RangeAmbient to 220 °C
Transfer Line Temperature RangeAmbient to 260 °C
Cold Trap Temperature−35 °C
Temperature Control Accuracy±1 °C
Analyte Recovery Rate>98% (compound-dependent)
Sample Capacity50 Adsorption Tubes
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAPL
OriginSichuan, China
Manufacturer TypeManufacturer
Product CategoryDomestic
ModelAPL-TD-2
Instrument TypeTwo-Stage Thermal Desorber, Thermal Desorber
Desorption Temperature RangeAmbient to 400 °C
Cold Trap Temperature Range−35 °C
Desorption Recovery Rate>98%
Sample Position Count1
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAPL
OriginSichuan, China
Manufacturer TypeDirect Manufacturer
Instrument TypeStatic Headspace Sampler
Automation LevelFully Automatic
Sample Tray Capacity20 positions
Vial Size20 mL (also compatible with 10 mL)
Oven Temperature RangeAmbient to 260 °C
Valve & Transfer Line Temperature RangeAmbient to 220 °C
Quantitative Loop Volume1 mL
Pressure Control Range0–0.4 MPa (adjustable)
Backflush Flow Rate0–400 mL/min (adjustable)
Temperature Stability< ±0.1 °C
PrecisionRSD ≤ 1% (200 ppm ethanol in water, n = 5)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAPL
OriginSichuan, China
Manufacturer TypeManufacturer
Region of OriginDomestic (China)
ModelAPL-TD25
Instrument TypeDual-Stage Thermal Desorber
Automation LevelFully Automated
Desorption Temperature Range−35 °C to 400 °C
Valve Injection Zone Temperature RangeAmbient to 300 °C
Transfer Line Temperature RangeAmbient to 300 °C
Cold Trap Temperature Range−35 °C
Temperature Control Accuracy< ±0.1 °C
Analyte Recovery Rate>98% (compound-dependent)
Sample Capacity25 adsorption tubes
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuazhun Chromatography
ModelGC-2021plus
OriginJiangxi, China
Instrument TypeLaboratory Gas Chromatograph
Application ScopeGeneral-purpose
Oven Temperature Range5 °C to 450 °C
Maximum Ramp Rate250 °C/min
Cooling Rate≤8 min (from 350 °C to 50 °C at 25 °C ambient)
Carrier Gas Flow Control Range0–200 mL/min (N₂), 0–1250 mL/min (H₂ or He)
Carrier Gas Pressure Control Range0–1035 kPa (0–150 psi)
Injector Maximum Operating Temperature420 °C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAPL
OriginSichuan, China
Manufacturer TypeDirect Manufacturer
Instrument TypeStatic Headspace Sampler
Automation LevelFully Automated
Sample Tray Capacity16 positions (all heated)
Vial Size Compatibility10 mL and 20 mL (20 mL standard)
Oven Temperature RangeAmbient to 260 °C
Valve & Transfer Line Temperature RangeAmbient to 220 °C
Temperature Control Accuracy±0.1 °C
Loop Volume1 mL
Pressurization Range0–0.4 MPa (continuously adjustable)
Purge Flow Rate0–400 mL/min (continuously adjustable)
PrecisionRSD ≤1.5% (ethanol in water, 400 ppm, n=5)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAPL
OriginSichuan, China
Manufacturer TypeDirect Manufacturer
Regional ClassificationDomestic (China)
ModelGC-7890
Instrument TypeLaboratory Gas Chromatograph
Application ScopeGeneral-Purpose
Oven Temperature Range5 °C above ambient to 420 °C (1 °C increment programmable)
Maximum Oven Operating Temperature400 °C
Heating RateUp to 40 °C/min
Cooling Rate280 °C → 50 °C in ≤8 min
Carrier Gas Flow Control Range0–50 mL/min
Carrier Gas Pressure Control Range0–0.35 MPa
Injector Maximum Temperature400 °C
Injector Pressure Setting Range0–0.35 MPa
Total Injector Flow Setting Range0–500 mL/min
Temperature Stability (≤180 °C)±0.01 °C
Temperature Stability (full range)±0.1 °C
Programmable Temperature Ramping7-stage
Independent Temperature ControlDual vaporizers (capillary & packed column)
Detector ConfigurationFID (Hydrogen Flame Ionization Detector)
FID Detection Limit≤5×10⁻¹² g/s (n-hexadecane)
FID Noise≤5×10⁻¹⁴ A
FID Drift≤1×10⁻¹³ V/h
FID Linear Dynamic Range≥10⁷
Column CompatibilityUp to three packed columns or two capillary columns simultaneously
Detector CapacityUp to three detectors + methanizer
Optional FeaturesIntegrated AD conversion circuit, cryogenic oven operation (dry ice/liquid nitrogen), dual rear doors with intelligent control, ceramic or quartz jet nozzles
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAPL
OriginSichuan, China
Manufacturer TypeDirect Manufacturer
Regional ClassificationDomestic (China)
ModelAPL-AS-24
Instrument TypeGas Chromatography Autosampler
Maximum Sample Capacity24 positions (expandable to 160)
Minimum Injection Volume0.1 µL
Maximum Injection Volume250 µL
Replicate Injections per Vialup to 99
Syringe Options1, 5, 10, 25, 50, 100, 250, 500 µL
Solvent Bottle Positions2 (expandable to 11)
Waste Bottle Positions1 (expandable to 5)
Method Storageup to 20 methods
Needle Wash Cyclesup to 99
Pump Draw Cyclesup to 99
Viscosity Delay0–60 s
Dwell Time Pre-/Post-Insertion0–120 s
Injection Timing Reproducibility (Dual-Tower Mode)< 1 ms
Communication InterfacesModbus RTU, USB 2.0
Operating Temperature−20 °C to 50 °C
Storage Temperature−40 °C to 70 °C
Operating Humidity10–90% RH
Storage Humidity5–90% RH
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAPL
OriginSichuan, China
Manufacturer TypeDirect Manufacturer
Instrument CategoryDomestic (China-made)
ModelAPL-PT-75
Sample Tray Capacity75 positions
Injection PrecisionRSD < 3%
Trap Temperature Range–30 °C to 400 °C
Sample Heating TemperatureAmbient to 120 °C
Sample Vial Cooling Temperature–30 °C
Purge Gas Flow Rate0–100 mL/min (adjustable)
Back-Flush Flow Rate0–100 mL/min (adjustable)
Water Removal Trap TempAmbient to 240 °C
Valve & Transfer Line TempAmbient to 220 °C
Sample Vial Size40 mL
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAPL
OriginSichuan, China
Manufacturer TypeDirect Manufacturer
Instrument TypeStatic Headspace Sampler
Automation LevelSemi-Automatic
Sample Vial Heating RangeAmbient to 250 °C
Valve Temperature Control RangeAmbient to 220 °C
Loop Volume2 mL
Vial Positions9
Vial Capacity20 mL
Temperature Setting Increment1 °C
Temperature Stability< ±0.1 °C
RSD (Repeatability)< 1.5%
Pressurization Range0–0.4 MPa (adjustable)
Purge Flow Rate0–20 mL/min (adjustable)
InterfaceTouchscreen with Time-Programmed Sequence Control
GC SynchronizationSupported via TTL or external trigger
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAPL
OriginShanghai, China
Manufacturer TypeManufacturer
Instrument TypeLaboratory Gas Chromatograph
Temperature Control Range8°C above ambient to 425°C
Oven Ramp RateUp to 75°C/min
Carrier Gas Pressure Control Range0–689.47 kPa (0–100 psi)
Injector Maximum Operating Temperature400°C
Injector Pressure Setting Range0–689.47 kPa
Injector Total Flow Setting Range0–100 psi
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAPL
OriginSichuan, China
Manufacturer TypeDirect Manufacturer
ModelKL-01
Heating Module Temperature RangeAmbient to 150 °C
Gas Flow Control Range0–300 mL/min (dynamically adjustable)
Flow Control Accuracy≤ 0.1 mL/min
Maximum Operating Pressure≥ 1.0 MPa
Concentration Range Supportedppt to ppm