| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | APL-PT-100 |
| Sample Capacity | 100 positions |
| Injection Precision | RSD < 3% |
| Trap Temperature Range | −30 °C to 400 °C |
| Purge Sample Heating Temperature | Ambient to 120 °C |
| Sample Vial Cooling Temperature | −30 °C |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | APL-PTC100 |
| Instrument Type | Water & Soil VOC Analysis System |
| Sample Tray Capacity | 1 position |
| Injection Precision | RSD < 3% |
| Trap Temperature Range | –30 °C to 220 °C |
| Sample Heating Temperature Range | Ambient to 220 °C |
| Sample Vial Cooling Temperature | 20 °C |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic (China-made) |
| Model | APL-PT-75 |
| Sample Tray Capacity | 75 positions |
| Injection Precision | RSD < 3% |
| Trap Temperature Range | –30 °C to 400 °C |
| Sample Heating Temperature | Ambient to 120 °C |
| Sample Vial Cooling Temperature | –30 °C |
| Purge Gas Flow Rate | 0–100 mL/min (adjustable) |
| Back-Flush Flow Rate | 0–100 mL/min (adjustable) |
| Water Removal Trap Temp | Ambient to 240 °C |
| Valve & Transfer Line Temp | Ambient to 220 °C |
| Sample Vial Size | 40 mL |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | PT30D |
| Instrument Type | Water & Soil Integrated VOC Analyzer |
| Sample Tray Capacity | 30 positions |
| Injection Precision | RSD < 3% |
| Trap Temperature Range | –30 °C to 400 °C |
| Sample Heating Temperature | Ambient to 120 °C |
| Vial Cooling Temperature | –30 °C |
| Desiccant Trap Temperature | Ambient to 240 °C |
| Valve & Transfer Line Temperature | Ambient to 220 °C |
| Purge Flow Rate | 0–100 mL/min (adjustable) |
| Back-Flush Flow Rate | 0–100 mL/min (adjustable) |
| Vial Volume | 40 mL |
| Brand | APL Optolab |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | APL-PTC30 |
| Sample Capacity | 30 positions |
| Injection Precision | RSD < 3% |
| Trap Temperature Range | −30 °C to 400 °C |
| Sample Heating Temperature | Ambient to 120 °C |
| Vial Cooling Temperature | −30 °C |
| Purge Flow Rate | 0–100 mL/min (adjustable) |
| Desorption Time | 1–3 min |
| Bake-out Temperature | Up to 250 °C |
| Trap Desorption Efficiency | Optimized for VOCs with C2–C12 volatility range |
| Compliance | ASTM D6866, EPA Method 502.2, EPA Method 524.2, EPA Method 8260D, HJ 605–2011, HJ 639–2012, HJ 686–2014, HJ 713–2014, HJ 735–2015, HJ 866–2017, HJ 893–2017, HJ 896–2017, HJ 1020–2019, SL 393–2007 |
| Brand | APL Optol |
|---|---|
| Model | PT-75D |
| Sample Capacity | 75 positions |
| Injection Precision | RSD < 3% |
| Trap Temperature Range | −30 °C to 400 °C |
| Sample Heating Range | Ambient to 120 °C |
| Sample Vial Cooling | −30 °C |
| Water Removal Trap Temp | Ambient to 240 °C |
| Valve & Transfer Line Temp | Ambient to 220 °C |
| Purge Flow | 0–100 mL/min (adjustable) |
| Desorption Time | 1–3 min |
| Bake-out Temp | Up to 250 °C |
| Vial Format | 40 mL |