- All
- Favorite
- Popular
- Most rated
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | APL-AGS-36 |
| Instrument Type | Gas Chromatography Autosampler |
| Max Sample Capacity | 132 positions |
| Minimum Injection Volume | 1 mL |
| Quantitative Loop Volume | 1 mL |
| Sample Tray Configuration | 36-position base (expandable in 12-position modules) |
| Compatible Sampling Devices | Gas-tight syringes and Tedlar®/aluminized gas bags |
| Tubing Material | PTFE |
| Valve Body | PEEK |
| Valve Core | Polyimide (PI) |
| Carrier Gas Line Purge Flow Rate | Up to 0.5 L/min |
| Injection Precision | R² ≥ 0.9999 for total hydrocarbons and methane peak areas across five replicate injections |
| Dimensions (L×W×H) | 450 × 500 × 430 mm |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Region Category | Domestic (China) |
| Model | DK-400 |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Manual Operation |
| Vial Heating Range | Ambient to 250 °C |
| Valve & Transfer Line Temperature Control Range | Ambient to 220 °C |
| Sample Loop Volume | 1.0 mL |
| Vial Capacity | 9 positions |
| Vial Size | 40 mL |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | APL-TD-50D |
| Instrument Type | Two-Stage Thermal Desorber / Thermal Desorption Unit |
| Automation Level | Fully Automated |
| Desorption Temperature Range | –35 °C to 400 °C |
| Valve Injection Zone Temperature Range | Ambient to 300 °C |
| Transfer Line Temperature Range | Ambient to 300 °C |
| Cold Trap Temperature Range | –35 °C |
| Temperature Control Accuracy | ±1 °C |
| Analyte Recovery Rate | >98% |
| Sample Capacity | 50 Adsorption Tubes |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | HS-Auto126 |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Sample Vial Heating Range | Ambient to 280 °C |
| Valve Temperature Control Range | Ambient to 280 °C |
| Sample Loop Volume | 1 mL / 2 mL |
| Temperature Control Accuracy | ±0.1 °C |
| Sample Capacity | 126 positions |
| Vial Format | 20 mL standard (10 mL optional) |
| Sample Zone Heating Range | Ambient to 260 °C |
| Valve & Transfer Line Heating Range | Ambient to 220 °C |
| Precision | RSD ≤1% (200 ppm ethanol in water, n=5) |
| Pressurization Range | 0–0.4 MPa (adjustable) |
| Purge Flow Rate | 0–100 mL/min (adjustable) |
| Vial Heating Positions | 15 |
| Oscillation Mode | Vertical wave-like agitation during equilibration |
| Display | 7-inch capacitive touchscreen |
| Method Storage | Preloaded compliance methods (e.g., EPA 502.2, USP <467>, ISO 11843-3) |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | HS-12 |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Semi-Automatic |
| Sample Vial Heating Range | Ambient to 250 °C |
| Valve Temperature Control Range | Ambient to 220 °C |
| Loop Volume | 2 mL |
| Vial Capacity | 12 positions |
| Vial Size | 20 mL |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | APL-PT-100 |
| Sample Capacity | 100 positions |
| Injection Precision | RSD < 3% |
| Trap Temperature Range | −30 °C to 400 °C |
| Purge Sample Heating Temperature | Ambient to 120 °C |
| Sample Vial Cooling Temperature | −30 °C |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | HS-45 |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automated |
| Vial Heating Range | Ambient to 260 °C (1 °C increments) |
| Valve Temperature Control Range | Ambient to 240 °C (1 °C increments) |
| Sample Loop Volume | 1 mL |
| Temperature Control Accuracy | ±0.1 °C |
| Vial Capacity | 45 positions |
| Compatible Vial Sizes | 10 mL and 20 mL |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | APL-PTC100 |
| Instrument Type | Water & Soil VOC Analysis System |
| Sample Tray Capacity | 1 position |
| Injection Precision | RSD < 3% |
| Trap Temperature Range | –30 °C to 220 °C |
| Sample Heating Temperature Range | Ambient to 220 °C |
| Sample Vial Cooling Temperature | 20 °C |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automated |
| Sample Tray Capacity | 20 positions |
| Vial Size | 20 mL (standard), 10 mL (optional) |
| Oven Temperature Range | Ambient to 260 °C |
| Valve & Transfer Line Temperature Range | Ambient to 220 °C |
| Loop Volume | 1 mL |
| Pressure Control Range | 0–0.4 MPa (adjustable) |
| Purge Flow Rate | 0–400 mL/min (adjustable) |
| Temperature Stability | < ±0.1 °C |
| Precision | RSD ≤ 1% (200 ppm ethanol in water, n = 5) |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automated |
| Sample Tray Capacity | 80 positions |
| Vial Sizes Supported | 10 mL and 20 mL |
| Oven Temperature Range | Ambient to 260 °C (1 °C increments) |
| Valve Temperature Range | Ambient to 240 °C (1 °C increments) |
| Loop Volume | 1 mL |
| Temperature Control Accuracy | ±0.1 °C |
| Independent Heated Zones | Sample oven, injection valve, transfer line, and needle |
| Agitation | Adjustable speed, integrated into each of 15 heated positions |
| System Purge | Automatic inert gas flush after each injection |
| Leak Detection | Real-time vial presence verification |
| Software Interface | 7-inch touchscreen with bilingual (English/Chinese) UI, method storage, real-time GC status display (carrier gas & pressurization pressure), AFM-based flow monitoring |
| Compliance Support | Designed for GLP/GMP environments with audit-ready method logging, event timestamping, and system self-test at power-on |
| Mechanical Architecture | Dual three-axis rotary gantry for precise vial handling, piercing, sampling, and injection |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automated |
| Sample Tray Capacity | 60 positions (15 heated positions) |
| Backup Positions | 20 |
| Vial Size Compatibility | 10 mL and 20 mL (standard) |
| Oven Temperature Range | Ambient to 260 °C (1 °C increment) |
| Valve & Transfer Line Temperature Range | Ambient to 220 °C (1 °C increment) |
| Temperature Accuracy | ±0.1 °C |
| Pressure-Controlled Injection | 0–0.4 MPa (adjustable) |
| Purge Flow Rate | 0–400 mL/min (adjustable) |
| Precision | RSD ≤1% (200 ppm ethanol in water, n=5) |
| Injection Volume Control | Pressurization time + regulated pressure |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Dual-Stage Thermal Desorber |
| Automation Level | Fully Automated |
| Desorption Temperature Range | Ambient to 400 °C |
| Valve & Injection Port Temperature Range | Ambient to 220 °C |
| Transfer Line Temperature Range | Ambient to 260 °C |
| Cold Trap Temperature | −35 °C |
| Temperature Control Accuracy | ±1 °C |
| Analyte Recovery Rate | >98% (compound-dependent) |
| Sample Capacity | 50 Adsorption Tubes |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | APL-TD-2 |
| Instrument Type | Two-Stage Thermal Desorber, Thermal Desorber |
| Desorption Temperature Range | Ambient to 400 °C |
| Cold Trap Temperature Range | −35 °C |
| Desorption Recovery Rate | >98% |
| Sample Position Count | 1 |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Sample Tray Capacity | 20 positions |
| Vial Size | 20 mL (also compatible with 10 mL) |
| Oven Temperature Range | Ambient to 260 °C |
| Valve & Transfer Line Temperature Range | Ambient to 220 °C |
| Quantitative Loop Volume | 1 mL |
| Pressure Control Range | 0–0.4 MPa (adjustable) |
| Backflush Flow Rate | 0–400 mL/min (adjustable) |
| Temperature Stability | < ±0.1 °C |
| Precision | RSD ≤ 1% (200 ppm ethanol in water, n = 5) |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Manufacturer |
| Region of Origin | Domestic (China) |
| Model | APL-TD25 |
| Instrument Type | Dual-Stage Thermal Desorber |
| Automation Level | Fully Automated |
| Desorption Temperature Range | −35 °C to 400 °C |
| Valve Injection Zone Temperature Range | Ambient to 300 °C |
| Transfer Line Temperature Range | Ambient to 300 °C |
| Cold Trap Temperature Range | −35 °C |
| Temperature Control Accuracy | < ±0.1 °C |
| Analyte Recovery Rate | >98% (compound-dependent) |
| Sample Capacity | 25 adsorption tubes |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automated |
| Sample Tray Capacity | 16 positions (all heated) |
| Vial Size Compatibility | 10 mL and 20 mL (20 mL standard) |
| Oven Temperature Range | Ambient to 260 °C |
| Valve & Transfer Line Temperature Range | Ambient to 220 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Loop Volume | 1 mL |
| Pressurization Range | 0–0.4 MPa (continuously adjustable) |
| Purge Flow Rate | 0–400 mL/min (continuously adjustable) |
| Precision | RSD ≤1.5% (ethanol in water, 400 ppm, n=5) |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | APL-AS-24 |
| Instrument Type | Gas Chromatography Autosampler |
| Maximum Sample Capacity | 24 positions (expandable to 160) |
| Minimum Injection Volume | 0.1 µL |
| Maximum Injection Volume | 250 µL |
| Replicate Injections per Vial | up to 99 |
| Syringe Options | 1, 5, 10, 25, 50, 100, 250, 500 µL |
| Solvent Bottle Positions | 2 (expandable to 11) |
| Waste Bottle Positions | 1 (expandable to 5) |
| Method Storage | up to 20 methods |
| Needle Wash Cycles | up to 99 |
| Pump Draw Cycles | up to 99 |
| Viscosity Delay | 0–60 s |
| Dwell Time Pre-/Post-Insertion | 0–120 s |
| Injection Timing Reproducibility (Dual-Tower Mode) | < 1 ms |
| Communication Interfaces | Modbus RTU, USB 2.0 |
| Operating Temperature | −20 °C to 50 °C |
| Storage Temperature | −40 °C to 70 °C |
| Operating Humidity | 10–90% RH |
| Storage Humidity | 5–90% RH |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic (China-made) |
| Model | APL-PT-75 |
| Sample Tray Capacity | 75 positions |
| Injection Precision | RSD < 3% |
| Trap Temperature Range | –30 °C to 400 °C |
| Sample Heating Temperature | Ambient to 120 °C |
| Sample Vial Cooling Temperature | –30 °C |
| Purge Gas Flow Rate | 0–100 mL/min (adjustable) |
| Back-Flush Flow Rate | 0–100 mL/min (adjustable) |
| Water Removal Trap Temp | Ambient to 240 °C |
| Valve & Transfer Line Temp | Ambient to 220 °C |
| Sample Vial Size | 40 mL |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Semi-Automatic |
| Sample Vial Heating Range | Ambient to 250 °C |
| Valve Temperature Control Range | Ambient to 220 °C |
| Loop Volume | 2 mL |
| Vial Positions | 9 |
| Vial Capacity | 20 mL |
| Temperature Setting Increment | 1 °C |
| Temperature Stability | < ±0.1 °C |
| RSD (Repeatability) | < 1.5% |
| Pressurization Range | 0–0.4 MPa (adjustable) |
| Purge Flow Rate | 0–20 mL/min (adjustable) |
| Interface | Touchscreen with Time-Programmed Sequence Control |
| GC Synchronization | Supported via TTL or external trigger |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automated |
| Sample Vial Heating Range | Ambient to 260 °C |
| Valve & Transfer Line Temperature Control Range | Ambient to 220 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Loop Volume | 1 mL |
| Vial Capacity | 40 positions |
| Vial Size Compatibility | 20 mL (standard), 10 mL (optional) |
| Precision | RSD ≤1% (200 ppm ethanol in water, n=5) |
| Pressure-Controlled Injection Range | 0–0.4 MPa (adjustable) |
| Purge Flow Rate | 0–400 mL/min (adjustable) |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | PT30D |
| Instrument Type | Water & Soil Integrated VOC Analyzer |
| Sample Tray Capacity | 30 positions |
| Injection Precision | RSD < 3% |
| Trap Temperature Range | –30 °C to 400 °C |
| Sample Heating Temperature | Ambient to 120 °C |
| Vial Cooling Temperature | –30 °C |
| Desiccant Trap Temperature | Ambient to 240 °C |
| Valve & Transfer Line Temperature | Ambient to 220 °C |
| Purge Flow Rate | 0–100 mL/min (adjustable) |
| Back-Flush Flow Rate | 0–100 mL/min (adjustable) |
| Vial Volume | 40 mL |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | APL-TD-1 |
| Instrument Type | Primary Thermal Desorber |
| Automation Level | Fully Automatic |
| Desorption Temperature Range | Ambient to 400 °C |
| Cold Trap Temperature Range | −35 °C to 25 °C (Note: Input states “25” — interpreted as upper limit of ambient-cooled trap |
| Desorption Recovery Rate | >98% |
| Sample Position Capacity | 1 |
| Brand | APL Optolong |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | APL-TD20N |
| Instrument Type | Dual-Stage Thermal Desorber |
| Desorption Temperature Range | –35 °C to 400 °C |
| Cold Trap Temperature Range | –35 °C |
| Desorption Recovery Rate | >98% (compound-dependent) |
| Sample Capacity | 20 adsorption tubes |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | APL-TC-20 |
| Temperature Control Range | Ambient to 400 °C |
| Gas Flow Rate | 0.3–3 L/min |
| Tube Capacity | 20 tubes |
| Temperature Accuracy | ±1 °C |
| Timer Range | 1 min to 99 h 99 min |
| Flow Adjustment Range | 0–3 L/min |
| Simultaneous Activation | 1–20 adsorption tubes |
Show next