Empowering Scientific Discovery

ASDevices Canada

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandASD
OriginCanada
ModelKA5800
Instrument TypeOnline Analyzer
Application ScopeGeneral-Purpose
Operating SystemEmbedded Linux with Touchscreen Interface
Detection PrincipleDual-Polarity Pulsed Electrochemical Conductivity Detection
Data AcquisitionReal-Time Asynchronous Parallel Chromatography
Sample IntroductionAutomated Multi-Channel Switching with Integrated Pre-Treatment Module
Calibration MethodSingle-Point Standard-Based Auto-Calibration
Detection EnhancementeLOD Noise-Filtering Algorithm (3–5× Sensitivity Gain)
Gas Capture TechnologyMulti-Threaded Aeration Trapping (KA5800-EIC Variant, Patent Pending)
Analysis Cycle<30 min per Full Sequence
Sample Volume Requirement≤1.5 L for ppb-Level Analysis
Compliance FrameworkDesigned for GLP/GMP Environments
Temperature ControlDigital Precision Dual-Zone Column & Detector Thermostat
Added to wishlistRemoved from wishlist 0
Add to compare
BrandASD
OriginCanada
ModelKA8000plus-S
Instrument TypeLaboratory Gas Chromatograph
Application FieldHydrogen Fuel Purity Analysis
Temperature Control RangeAmbient +4 °C to 450 °C
Maximum Ramp Rate75 °C/min
Cooling Rate~6 min (400 °C → 50 °C)
Carrier Gas Flow Range & Control30–100 mL/min
Carrier Gas Pressure Range & Control90–100 psig
Injector Max Operating Temperature400 °C
Injector Pressure Setting Range3–25 psig
Injector Total Flow Setting Range5–200 mL/min
DetectorSePDD (Sulfur-Enhanced Plasma Discharge Detector)
Valve ConfigurationPLSV Inert 6-Port Valve with 2 mL Inert Quantitative Loop
Carrier Gas RequirementUltra-High-Purity Helium (≥5.0, purified to <1 ppb total impurities via ASDPure gas purifier)
Detection Limit<0.5 ppb (as H₂S equivalent, direct injection)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandASD
OriginCanada
ModelKA8000
Instrument TypeOnline Gas Chromatograph
Temperature Control RangeAmbient + 4 °C to 450 °C
Ramp Rate30–60 °C/min
Cool-down Rate30–60 °C/min
Carrier Gas Flow Range & Control20–50 mL/min
Carrier Gas Pressure Range & Control90–100 psig
Injector Maximum Operating Temperature200 °C
Injector Pressure Setting Range5–15 psig
Injector Total Flow Setting Range20–30 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandASD
OriginCanada
Manufacturer TypeAuthorized Distributor
Import StatusImported
ModelFEPID
Compatible InstrumentGas Chromatograph (GC)
Detector TypePhotoionization Detector (PID)
Wavelength Range100–900 nm
Detection PrincipleEmission-based Photoionization
UV SourceDielectric Barrier Discharge (DBD) Ultraviolet Lamp
Noise Level<1% RMS
Detection Limit1 ppb (for benzene-equivalent VOCs)
Baseline Drift<1% over 24 h
Signal Channels4 independent analog/digital outputs
Calibration Accuracy & Repeatability±0.1% of full scale
Added to wishlistRemoved from wishlist 0
Add to compare
BrandASD
OriginCanada
Manufacturer TypeGeneral Distributor
Origin CategoryImported
ModelSePdd
QuotationUpon Request
Compatible InstrumentGas Chromatograph
Instrument TypeSpecialized Chromatographic Detector
Wavelength Range100 nm – 900 nm
Detection ModeEmission
Light SourcePlasma Discharge
Noise<1%
Detection Limit1 ppb
Baseline Drift<1%
Signal Channels4
Adjustment Accuracy / Repeatability±1%
Added to wishlistRemoved from wishlist 0
Add to compare
BrandASD
OriginCanada
ModelIC-KA5800
Instrument TypeOnline Analyzer
Application ScopeUniversal Gas Impurity Analysis
Compliance FrameworkASTM D7622, ISO 14687-2, GB/T 37244–2018, USP <645> (for total ionizable impurities)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandASD
OriginCanada
ModelKa6000 Plus
Instrument TypeOnline Gas Chromatograph
Temperature Control RangeAmbient +4 °C to 450 °C
Maximum Ramp Rate75 °C/min
Cooling Rate~6 min (from 400 °C to 50 °C)
Carrier Gas Flow Range30–100 mL/min
Carrier Gas Pressure Range90–100 psig
Injector Max Operating Temperature400 °C
Injector Pressure Setting Range3–25 psig
Injector Total Flow Setting Range5–200 mL/min
Column Oven ZonesUp to 4 independently controlled zones
ValvesUp to 5 programmable PLSV valves
DetectorsUp to 2 gas-phase detectors (e.g., EPD)
Detection Limit (LOD)<1 ppb (stable, compound-dependent)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandASD
OriginCanada
ModelPAD
Instrument TypeLaboratory Gas Chromatograph
Application FieldCoal Industry-Specific
Temperature Control Range−4 °C to 450 °C
Oven Ramp Rate30–60 °C/min
Oven Cool-Down Rate30–60 °C/min
Carrier Gas Flow Range & Control20–50 mL/min
Carrier Gas Pressure Range & Control90–100 psig
Injector Maximum Operating Temperature200 °C
Injector Pressure Setting Range5–15 psig
Injector Total Flow Setting Range20–30 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandASDevices
OriginCanada
ModelGC-EPD
Compatible InstrumentGas Chromatograph
Detector TypePlasma-Based Universal Detector
Wavelength Range100 nm – 900 nm
Detection ModeEmission
Excitation SourceRadio-Frequency Plasma
Noise Level0.1 mV (RMS, 1 Hz bandwidth)
Detection Limit0.5 ppb (for halogenated compounds)
Baseline Drift≤1% over 24 h
Signal Channels4 independent analog inputs
Calibration Accuracy & Reproducibility±1% (full-scale)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKA
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Regional ClassificationDomestic (China)
Modelhytrace Integrated Analyzer
Instrument TypePortable Gas Chromatograph
Application ScopeGeneral-purpose, Hydrogen Purity Monitoring
Oven Temperature RangeAmbient +4 °C to 450 °C
Ramp RateUp to 75 °C/min
Cool-down Time~6 min (from 400 °C to 50 °C)
Carrier Gas Flow Control Range30–100 mL/min
Carrier Gas Pressure Control Range90–100 psig
Injector Maximum Temperature400 °C
Injector Pressure Setting Range3–25 psig
Injector Total Flow Setting Range5–200 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandASDevices
OriginCanada
ModelCYPPB-01
Instrument TypeOnline Gas Chromatograph
Application ScopeGeneral-Purpose
Dilution Ratio Range1:2 to 1:3500 (customizable up to 1:10,000)
Relative Accuracy< 0.5%
Certified TraceabilityNIST-traceable calibration certificate
Core TechnologyCritical-Orifice-Based Sonic Nozzle Dynamic Dilution
ConstructionAll-welded stainless steel flow path
Temperature-Controlled PathUp to 200 °C
Pressure RegulationDual EPC with temperature compensation
Flow Configuration OptionsDirect-coupled or high-integrity bypass
Purification ModuleiGCSASDPure integrated gas purifier
ComplianceDesigned for ISO/IEC 17025-compliant calibration labs and GLP/GMP environments