| Brand | ASD |
|---|---|
| Origin | Canada |
| Model | KA5800 |
| Instrument Type | Online Analyzer |
| Application Scope | General-Purpose |
| Operating System | Embedded Linux with Touchscreen Interface |
| Detection Principle | Dual-Polarity Pulsed Electrochemical Conductivity Detection |
| Data Acquisition | Real-Time Asynchronous Parallel Chromatography |
| Sample Introduction | Automated Multi-Channel Switching with Integrated Pre-Treatment Module |
| Calibration Method | Single-Point Standard-Based Auto-Calibration |
| Detection Enhancement | eLOD Noise-Filtering Algorithm (3–5× Sensitivity Gain) |
| Gas Capture Technology | Multi-Threaded Aeration Trapping (KA5800-EIC Variant, Patent Pending) |
| Analysis Cycle | <30 min per Full Sequence |
| Sample Volume Requirement | ≤1.5 L for ppb-Level Analysis |
| Compliance Framework | Designed for GLP/GMP Environments |
| Temperature Control | Digital Precision Dual-Zone Column & Detector Thermostat |
| Brand | ASD |
|---|---|
| Origin | Canada |
| Model | KA8000plus-S |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Hydrogen Fuel Purity Analysis |
| Temperature Control Range | Ambient +4 °C to 450 °C |
| Maximum Ramp Rate | 75 °C/min |
| Cooling Rate | ~6 min (400 °C → 50 °C) |
| Carrier Gas Flow Range & Control | 30–100 mL/min |
| Carrier Gas Pressure Range & Control | 90–100 psig |
| Injector Max Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 3–25 psig |
| Injector Total Flow Setting Range | 5–200 mL/min |
| Detector | SePDD (Sulfur-Enhanced Plasma Discharge Detector) |
| Valve Configuration | PLSV Inert 6-Port Valve with 2 mL Inert Quantitative Loop |
| Carrier Gas Requirement | Ultra-High-Purity Helium (≥5.0, purified to <1 ppb total impurities via ASDPure gas purifier) |
| Detection Limit | <0.5 ppb (as H₂S equivalent, direct injection) |
| Brand | ASD |
|---|---|
| Origin | Canada |
| Model | KA8000 |
| Instrument Type | Online Gas Chromatograph |
| Temperature Control Range | Ambient + 4 °C to 450 °C |
| Ramp Rate | 30–60 °C/min |
| Cool-down Rate | 30–60 °C/min |
| Carrier Gas Flow Range & Control | 20–50 mL/min |
| Carrier Gas Pressure Range & Control | 90–100 psig |
| Injector Maximum Operating Temperature | 200 °C |
| Injector Pressure Setting Range | 5–15 psig |
| Injector Total Flow Setting Range | 20–30 mL/min |
| Brand | ASD |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | FEPID |
| Compatible Instrument | Gas Chromatograph (GC) |
| Detector Type | Photoionization Detector (PID) |
| Wavelength Range | 100–900 nm |
| Detection Principle | Emission-based Photoionization |
| UV Source | Dielectric Barrier Discharge (DBD) Ultraviolet Lamp |
| Noise Level | <1% RMS |
| Detection Limit | 1 ppb (for benzene-equivalent VOCs) |
| Baseline Drift | <1% over 24 h |
| Signal Channels | 4 independent analog/digital outputs |
| Calibration Accuracy & Repeatability | ±0.1% of full scale |
| Brand | ASD |
|---|---|
| Origin | Canada |
| Manufacturer Type | General Distributor |
| Origin Category | Imported |
| Model | SePdd |
| Quotation | Upon Request |
| Compatible Instrument | Gas Chromatograph |
| Instrument Type | Specialized Chromatographic Detector |
| Wavelength Range | 100 nm – 900 nm |
| Detection Mode | Emission |
| Light Source | Plasma Discharge |
| Noise | <1% |
| Detection Limit | 1 ppb |
| Baseline Drift | <1% |
| Signal Channels | 4 |
| Adjustment Accuracy / Repeatability | ±1% |
| Brand | ASD |
|---|---|
| Origin | Canada |
| Model | IC-KA5800 |
| Instrument Type | Online Analyzer |
| Application Scope | Universal Gas Impurity Analysis |
| Compliance Framework | ASTM D7622, ISO 14687-2, GB/T 37244–2018, USP <645> (for total ionizable impurities) |
| Brand | ASD |
|---|---|
| Origin | Canada |
| Model | Ka6000 Plus |
| Instrument Type | Online Gas Chromatograph |
| Temperature Control Range | Ambient +4 °C to 450 °C |
| Maximum Ramp Rate | 75 °C/min |
| Cooling Rate | ~6 min (from 400 °C to 50 °C) |
| Carrier Gas Flow Range | 30–100 mL/min |
| Carrier Gas Pressure Range | 90–100 psig |
| Injector Max Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 3–25 psig |
| Injector Total Flow Setting Range | 5–200 mL/min |
| Column Oven Zones | Up to 4 independently controlled zones |
| Valves | Up to 5 programmable PLSV valves |
| Detectors | Up to 2 gas-phase detectors (e.g., EPD) |
| Detection Limit (LOD) | <1 ppb (stable, compound-dependent) |
| Brand | ASD |
|---|---|
| Origin | Canada |
| Model | PAD |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Coal Industry-Specific |
| Temperature Control Range | −4 °C to 450 °C |
| Oven Ramp Rate | 30–60 °C/min |
| Oven Cool-Down Rate | 30–60 °C/min |
| Carrier Gas Flow Range & Control | 20–50 mL/min |
| Carrier Gas Pressure Range & Control | 90–100 psig |
| Injector Maximum Operating Temperature | 200 °C |
| Injector Pressure Setting Range | 5–15 psig |
| Injector Total Flow Setting Range | 20–30 mL/min |
| Brand | ASDevices |
|---|---|
| Origin | Canada |
| Model | GC-EPD |
| Compatible Instrument | Gas Chromatograph |
| Detector Type | Plasma-Based Universal Detector |
| Wavelength Range | 100 nm – 900 nm |
| Detection Mode | Emission |
| Excitation Source | Radio-Frequency Plasma |
| Noise Level | 0.1 mV (RMS, 1 Hz bandwidth) |
| Detection Limit | 0.5 ppb (for halogenated compounds) |
| Baseline Drift | ≤1% over 24 h |
| Signal Channels | 4 independent analog inputs |
| Calibration Accuracy & Reproducibility | ±1% (full-scale) |
| Brand | KA |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | hytrace Integrated Analyzer |
| Instrument Type | Portable Gas Chromatograph |
| Application Scope | General-purpose, Hydrogen Purity Monitoring |
| Oven Temperature Range | Ambient +4 °C to 450 °C |
| Ramp Rate | Up to 75 °C/min |
| Cool-down Time | ~6 min (from 400 °C to 50 °C) |
| Carrier Gas Flow Control Range | 30–100 mL/min |
| Carrier Gas Pressure Control Range | 90–100 psig |
| Injector Maximum Temperature | 400 °C |
| Injector Pressure Setting Range | 3–25 psig |
| Injector Total Flow Setting Range | 5–200 mL/min |
| Brand | ASDevices |
|---|---|
| Origin | Canada |
| Model | CYPPB-01 |
| Instrument Type | Online Gas Chromatograph |
| Application Scope | General-Purpose |
| Dilution Ratio Range | 1:2 to 1:3500 (customizable up to 1:10,000) |
| Relative Accuracy | < 0.5% |
| Certified Traceability | NIST-traceable calibration certificate |
| Core Technology | Critical-Orifice-Based Sonic Nozzle Dynamic Dilution |
| Construction | All-welded stainless steel flow path |
| Temperature-Controlled Path | Up to 200 °C |
| Pressure Regulation | Dual EPC with temperature compensation |
| Flow Configuration Options | Direct-coupled or high-integrity bypass |
| Purification Module | iGCSASDPure integrated gas purifier |
| Compliance | Designed for ISO/IEC 17025-compliant calibration labs and GLP/GMP environments |