BrandASD
OriginCanada
ModelKA8000plus-S
Instrument TypeLaboratory Gas Chromatograph
Application FieldHydrogen Fuel Purity Analysis
Temperature Control RangeAmbient +4 °C to 450 °C
Maximum Ramp Rate75 °C/min
Cooling Rate~6 min (400 °C → 50 °C)
Carrier Gas Flow Range & Control30–100 mL/min
Carrier Gas Pressure Range & Control90–100 psig
Injector Max Operating Temperature400 °C
Injector Pressure Setting Range3–25 psig
Injector Total Flow Setting Range5–200 mL/min
DetectorSePDD (Sulfur-Enhanced Plasma Discharge Detector)
Valve ConfigurationPLSV Inert 6-Port Valve with 2 mL Inert Quantitative Loop
Carrier Gas RequirementUltra-High-Purity Helium (≥5.0, purified to <1 ppb total impurities via ASDPure gas purifier)
Detection Limit<0.5 ppb (as H₂S equivalent, direct injection)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandASD
OriginCanada
ModelKA8000
Instrument TypeOnline Gas Chromatograph
Temperature Control RangeAmbient + 4 °C to 450 °C
Ramp Rate30–60 °C/min
Cool-down Rate30–60 °C/min
Carrier Gas Flow Range & Control20–50 mL/min
Carrier Gas Pressure Range & Control90–100 psig
Injector Maximum Operating Temperature200 °C
Injector Pressure Setting Range5–15 psig
Injector Total Flow Setting Range20–30 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandASD
OriginCanada
ModelKa6000 Plus
Instrument TypeOnline Gas Chromatograph
Temperature Control RangeAmbient +4 °C to 450 °C
Maximum Ramp Rate75 °C/min
Cooling Rate~6 min (from 400 °C to 50 °C)
Carrier Gas Flow Range30–100 mL/min
Carrier Gas Pressure Range90–100 psig
Injector Max Operating Temperature400 °C
Injector Pressure Setting Range3–25 psig
Injector Total Flow Setting Range5–200 mL/min
Column Oven ZonesUp to 4 independently controlled zones
ValvesUp to 5 programmable PLSV valves
DetectorsUp to 2 gas-phase detectors (e.g., EPD)
Detection Limit (LOD)<1 ppb (stable, compound-dependent)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandASD
OriginCanada
ModelPAD
Instrument TypeLaboratory Gas Chromatograph
Application FieldCoal Industry-Specific
Temperature Control Range−4 °C to 450 °C
Oven Ramp Rate30–60 °C/min
Oven Cool-Down Rate30–60 °C/min
Carrier Gas Flow Range & Control20–50 mL/min
Carrier Gas Pressure Range & Control90–100 psig
Injector Maximum Operating Temperature200 °C
Injector Pressure Setting Range5–15 psig
Injector Total Flow Setting Range20–30 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKA
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Regional ClassificationDomestic (China)
Modelhytrace Integrated Analyzer
Instrument TypePortable Gas Chromatograph
Application ScopeGeneral-purpose, Hydrogen Purity Monitoring
Oven Temperature RangeAmbient +4 °C to 450 °C
Ramp RateUp to 75 °C/min
Cool-down Time~6 min (from 400 °C to 50 °C)
Carrier Gas Flow Control Range30–100 mL/min
Carrier Gas Pressure Control Range90–100 psig
Injector Maximum Temperature400 °C
Injector Pressure Setting Range3–25 psig
Injector Total Flow Setting Range5–200 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandASDevices
OriginCanada
ModelCYPPB-01
Instrument TypeOnline Gas Chromatograph
Application ScopeGeneral-Purpose
Dilution Ratio Range1:2 to 1:3500 (customizable up to 1:10,000)
Relative Accuracy< 0.5%
Certified TraceabilityNIST-traceable calibration certificate
Core TechnologyCritical-Orifice-Based Sonic Nozzle Dynamic Dilution
ConstructionAll-welded stainless steel flow path
Temperature-Controlled PathUp to 200 °C
Pressure RegulationDual EPC with temperature compensation
Flow Configuration OptionsDirect-coupled or high-integrity bypass
Purification ModuleiGCSASDPure integrated gas purifier
ComplianceDesigned for ISO/IEC 17025-compliant calibration labs and GLP/GMP environments
Show next