| Brand | ASD |
|---|---|
| Origin | Canada |
| Model | N2 Sense |
| Detection Limit | 0.5 ppb |
| Repeatability | <1% |
| Detector Type | Enhanced Plasma Discharge (EPD) |
| Column Temperature Range | Ambient +4 °C to 450 °C |
| Carrier Gas Requirement | High-Purity Gas |
| Output | 4–20 mA, Ethernet, RS-232, MQTT |
| Data Storage | 12-month onboard logging |
| Dimensions | 133 × 202 × 330 mm (19″ rack-mountable) |
| Power | 24 VDC, 40 W |
| Operating Temperature | 5–40 °C |
| Sample Flow Rate | 5–200 mL/min |
| Inlet Pressure | 3–25 PSIG |
| Response Time | <10 s (90% step change at 75 mL/min) |
| Drift | <0.5% FS |
| Measurement Ranges | 0–1 ppm, 0–10 ppm, 0–100 ppm, up to 1% N₂ in Ar/He |
| Brand | KA |
|---|---|
| Origin | Canada |
| Model | KA6000 |
| Repeatability | <1% |
| Detection Limit | 1 ppb |
| Detector Type | Enhanced Plasma Discharge Detector (EPD) |
| Column Oven Temperature Range | −5 °C to 300 °C |
| Carrier Gases | N₂, Ar, He |
| Compliance | Fully compatible with ASTM D7622, ISO 8573-5, USP <467>, and EPA Method TO-15/TO-17 workflows |
| Software | Embedded GC control platform with 21 CFR Part 11–compliant audit trail and GLP/GMP data integrity architecture |
| Brand | KA |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | KA8000Ex |
| Price Range | USD 68,000–136,000 (FOB) |
| Repeatability | <1% RSD |
| Detection Limit | <1 ppb (H₂S, COS, SO₂, CH₃SH) |
| Detector Type | Enhanced Plasma Detector (EPD) |
| Column Oven Temperature Range | −5°C to 300°C |
| Carrier Gas Requirements | Argon, Helium, or Nitrogen (inert only) |
| Brand | ASD |
|---|---|
| Origin | Canada |
| Model | KA0211 |
| Repeatability | ±1% FS |
| Detection Limit | 0.03 ppm |
| Detector Type | TCD (Thermal Conductivity Detector) |
| Column Oven Temperature Range | 5 °C to 45 °C |
| Carrier Gas Purity Requirement | 5N (99.999%) |
| Compliance | Designed for continuous online operation in industrial process environments |
| Configuration | Modular sensor architecture with field-replaceable sensing modules |
| Brand | ASD |
|---|---|
| Origin | Canada |
| Model | CGA |
| Price | USD 28,000 (approx.) |
| Linearity Error | <0.1% FS |
| Repeatability | <0.1% FS |
| Span Drift | ≤1% per 30 days |
| Response Time (T90) | 5 seconds |
| Explosion Protection | Not certified (non-hazardous area use only) |
| Sensor Technologies | FID, NDIR, Paramagnetic, Electrochemical (eCell), Alumina-based Hygrometer (Al₂O₃), EPD (Electrostatic Precipitation Detector) |
| Temperature Compensation | Integrated |
| Pressure Compensation | Integrated |
| Calibration Options | Multi-point auto-calibration available per module |
| Module Architecture | Up to 3 internal sensor modules + 1 external Al₂O₃ module |
| Data Logging | Onboard with real-time trend visualization |
| Brand | ASDevices |
|---|---|
| Origin | Canada |
| Model | KA8000Ex |
| Repeatability | ±2% |
| Detection Limit (MDL) | 0.5 ppb H₂S |
| Detector Type | EPD (Enhanced Plasma Discharge Detector) |
| Column Oven Temperature Range | −4 °C to 200 °C |
| Carrier Gas Requirement | 5N-grade He, Ar, or N₂ |
| Brand | KA |
|---|---|
| Origin | Canada |
| Model | KA 8000Plus |
| Repeatability | <1% RSD |
| Detection Limit | 0.5 ppb |
| Detector Type | Enhanced Plasma Discharge Detector (EPD) |
| Column Oven Temperature Range | –4 °C to 450 °C |
| Carrier Gas Requirement | Ultra-High-Purity Gases |
| Regulatory Status | Import-Class Industrial Instrument |
| Brand | ASD |
|---|---|
| Origin | Canada |
| Model | KA0221 |
| Repeatability | < ±0.1% O₂ |
| Detection Limit | < ±0.1% O₂ |
| Detector Type | Paramagnetic |
| Column Temperature Control Range | 5 °C to 45 °C |
| Gas Supply Purity | 5N (99.999%) |
| Output | 4–20 mA |
| Communication | RS-485, Ethernet, Modbus (optional) |
| Relay Outputs | 3 × user-configurable dry-contact relays |
| Data Export | CSV format |
| Calibration | Auto/manual zero/span, multi-point, calendar-based scheduling, programmable purge time, intelligent stability detection |