Beijing Beifen-Ruili Analytical Instrument (Group) Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Ruili
OriginBeijing, China
ModelSP-2110
Instrument TypeDedicated Gas Chromatograph for Dissolved Gas Analysis (DGA) in Transformer Oil
ComplianceDesigned to meet GB/T 17623–2017, DL/T 703–2015, and IEC 60567 requirements
InterfaceUSB 2.0
Data AcquisitionIntegrated with Transformer Oil DGA-Specific Chromatography Workstation
Injection SystemManual syringe injection with micro-switch trigger activation
Gas ControlEquipped with digital pressure and mass flow sensors for carrier gas (N₂, H₂, or Ar) and detector gases
Detector ConfigurationDual-TCD (Thermal Conductivity Detector) or TCD+FID (optional)
ColumnPre-packed stainless-steel capillary or packed column optimized for C₁–C₅ hydrocarbons and CO/CO₂ separation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Ruili
OriginBeijing, China
ModelWFX-810
Instrument TypeFlame and Graphite Furnace AAS
MonochromatorPlane Grating
Optical SystemDouble-Beam
DetectorPhotomultiplier Tube (PMT)
ResolutionResolves Mn 279.5 nm and 279.8 nm doublet with valley energy < 36%
SensitivityFlame mode — Cu 0.13 µg/mL per 1% absorption
Repeatability (RSD)Flame RSD ≤ 0.9%
Detection LimitFlame — Cu 0.010 µg/mL
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Ruili
OriginBeijing, China
ModelAES-8000 Series
Instrument TypeBenchtop Direct-Reading Spectrometer
Excitation SourceAC/DC Arc
DetectorUV-Sensitive CMOS Array
Focal Length600 mm
Grating Grooves2400 lines/mm
Wavelength Range230–340 nm
Spectral CoverageFull-Spectrum Acquisition
Optical DesignVertical Symmetric Ebert-Fastie
Reciprocal Linear Dispersion0.64 nm/mm (1st order)
Theoretical Spectral Resolution0.003 nm @ 300 nm
Spectrometer Chamber Temperature Control35 °C ± 0.1 °C
Arc Current Range2–20 A (AC), 2–15 A (DC)
Dimensions (L×W×H)1500 × 820 × 650 mm
Weight~180 kg
Operating Environment15–30 °C, RH < 80 %
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Ruili
OriginBeijing, China
ModelUV-2200
Optical DesignDouble-beam
DetectorPhotodiode Array (PDA)
Wavelength Range190–1100 nm
Wavelength Accuracy±0.25 nm
Spectral Bandwidth0.1 / 0.2 / 0.5 / 1.0 / 2.0 / 5.0 nm (6-step selectable)
Stray Light≤0.001% T (at 220 nm using NaI solution
Wavelength Scanning Resolution0.02 nm minimum sampling interval
Power SupplyAC 220 V / 50 Hz
Power Consumption400 W
Dimensions (W×D×H)730 × 530 × 230 mm
Net Weight40 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Ruili
OriginBeijing, China
ModelHMS7680
Instrument TypeIon Mobility Mass Spectrometer
Application ScopeGeneral-Purpose
Ionization SourcesESI and APCI
IM Resolution Modes3 Adjustable Settings
Mass Analyzer ConfigurationQuadrupole + Orthogonal TOF
Collision CellAxial DC Voltage Gradient CID with Tunable Collision Gas
Temperature ControlWater-Cooled, Thermally Stabilized Flight Tube with Intelligent Compensation
Acquisition Mode4D Full-Spectrum Simultaneous Detection
Software FeaturesAutomated Tuning, Real-Time Mass Calibration, Method Optimization, and Integrated Data Processing & Reporting
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (PRC)
ModelWQF-520
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Ruili
OriginBeijing, China
ModelUV-9600
Optical SystemSingle-beam
DetectorPhotodiode Array
Wavelength Range190–1100 nm
Wavelength Accuracy±2.0 nm
Spectral Bandwidth1.0, 2.0, 4.0, 5.0 nm (selectable)
Stray Light≤0.05% T (at 220 nm with NaI
Display16×2 LCD
Light SourcesPlug-in deuterium lamp (optional), plug-in tungsten-halogen lamp
Power SupplyAC 220 V/50 Hz or 110 V/60 Hz
Power Consumption120 W
Dimensions (W×D×H)530 × 410 × 210 mm
Net Weight16 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Ruili
OriginBeijing, China
ModelAF3000
Instrument TypeMulti-channel Atomic Fluorescence Spectrometer
Sample IntroductionPeristaltic Pump
Detectable ElementsAs, Sb, Bi, Se, Te, Pb, Sn, Hg, Cd, Ge, Zn, Au, Ag, Co, Cu, Ni
Relative Standard Deviation (RSD)< 0.7%
Linear Dynamic Range> 3 orders of magnitude
Detection LimitsAs, Sb, Bi, Se, Te, Pb, Sn < 0.01 µg/L
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Ruili
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Instrument TypeTriple Quadrupole (QqQ)
Application FieldGeneral-Purpose
Mass Range10–2250 Da
Ionization SourcesDual ESI/APCI
Collision CellCurved RF-only Quadrupole Design
Gas SystemCounter-Flow Curtain Gas Configuration
SoftwareIntegrated Intelligent Tuning, Calibration, Method Optimization & Reporting Engine
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Ruili
OriginBeijing, China
ModelWFX-320
Instrument TypeFlame AAS
MonochromatorPlane Grating
Optical SystemSingle-beam
DetectorPhotomultiplier Tube (PMT)
ResolutionResolves Mn 279.5 nm and 279.8 nm doublet with valley energy <36%
SensitivityCu 0.04 µg/mL per 1% absorption
Repeatability (RSD)≤0.9% (flame mode)
Detection LimitCu 0.007 µg/mL (flame mode)
Optional AccessoryHydride Generation System
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Ruili
OriginBeijing, China
ModelAF-640A
Instrument TypeMulti-channel Atomic Fluorescence Spectrometer
Sample IntroductionPeristaltic Pump
Detectable ElementsAs, Sb, Bi, Se, Te, Pb, Sn, Hg, Cd, Ge, Zn, Au (12 elements)
Relative Standard Deviation (RSD)<1%
Linear Dynamic Range>3 orders of magnitude
Detection LimitsAs, Sb, Bi, Se, Te, Pb, Sn: <0.01 µg/L
Hg, Cd<0.001 µg/L
Ge<0.05 µg/L
Zn<1.0 µg/L
Au<3.0 µg/L
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Ruili
OriginBeijing, China
ModelUV-2601
Optical DesignDual-beam
DetectorPhotodiode Array
Wavelength Range190–1100 nm
Wavelength Accuracy±0.3 nm
Spectral Bandwidth0.5–5.0 nm (5 selectable steps)
Stray Light≤0.1% T (at 220 nm using NaI
Display6-inch high-brightness blue LCD
Light SourcesSocket-type deuterium lamp and tungsten-halogen lamp
Power SupplyAC 220 V/50 Hz or 110 V/60 Hz
Power Consumption200 W
Dimensions (W×D×H)630 × 470 × 210 mm
Net Weight26 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Ruili
OriginBeijing, China
ModelSP-2120
Temperature Control Range20–400 °C above ambient
Ramp Rate0.5–35 °C/min
Cool-down Time<5 min (250 °C → 50 °C)
Carrier Gas Pressure Range & Control0–0.8 MPa
Injector Max Operating Temperature400 °C
Injector Pressure Setting Range0–0.8 MPa
Detection LimitsH₂ ≤5 ppm, CO ≤0.5 ppm, O₂/N₂ ≤0.05 vol%, CH₄/CO₂/C₂H₄/C₂H₆/C₂H₂ ≤0.1 ppm
Total Analysis Time≤7 min (single injection, 9-component full profile)
Simultaneous Active Detectors3 (TCD + dual FID)
Flow Sensors4-channel digital gas flow monitoring
Valve ConfigurationHigh-reliability imported 10-port rotary valve
Explosion Risk AssessmentReal-time calculation per GB/T 20964–2007 and AQ 1018–2006
ComplianceDesigned for GLP-compliant coal mine safety labs
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Ruili
OriginBeijing, China
ModelUV-1601
Optical DesignPseudo-Double-Beam
DetectorPhotodiode Array (PDA)
Wavelength Range190–1100 nm
Wavelength Accuracy±0.3 nm
Spectral Bandwidth0.5 / 1.0 / 2.0 / 4.0 / 5.0 nm (5-step selectable)
Stray Light≤0.1% T (at 220 nm with NaI
Auto Wavelength ScanningYes
Dimensions630 × 470 × 210 mm
Weight26 kg
Power SupplyAC 220 V/50 Hz or 110 V/60 Hz
Power Consumption180 W
InterfaceUSB port, optional PC control, printer output
Data RetentionNon-volatile memory for parameters and measurements
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Ruili
OriginBeijing, China
ModelSY9230
Instrument TypeLaboratory Benchtop Ion Chromatograph
Application ScopeGeneral-Purpose Anion and Cation Analysis
Pump Pressure Range0–35 MPa
Flow Rate Range0–9.999 mL/min
Eluent Flow Rate Accuracy0.1–5.0 mL/min
Max Operating Pressure35 MPa
Column Oven Temperature RangeAmbient +5 °C to 60 °C
Temperature Stability±0.2 °C
Eluent Concentration Range0.1–100 mM
Fluidic Path MaterialFull-PEEK (Polyetheretherketone)
Eluent GenerationOn-Demand Electrolytic Eluent Generator (EG) with Water-Only Input
DegassingIntegrated Low-Pressure Membrane Degasser + Gas-Liquid Separator
Safety FeaturesReal-Time Pressure Monitoring, Leak Detection, Eluent Reservoir Level Sensing, Auto-Shutdown Protocol
Consumables MonitoringColumn & Suppressor Usage Tracking with Auto-Recognition of New Units
Compliance SupportDesigned for GLP/GMP environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Ruili
OriginBeijing, China
ModelSP-5220
Instrument TypeLaboratory Gas Chromatograph
Application ScopeGeneral-Purpose
Regulatory ComplianceCE-marked per EN 61010-1, IEC 61326-1 (EMC), ISO/IEC 17025-compatible operation
Control SystemLinux-based embedded platform with Ethernet and USB 2.0 interfaces
Pressure Control Accuracy±0.001 psi (EPC)
Temperature Program Reproducibility±0.5% (RSD)
MTBF>12,000 hours
Safety CertificationUL 61010-1 / GB 4793.1 compliant
Electromagnetic CompatibilityTested to IEC 61326-1 Class A
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Ruili
OriginBeijing, China
ModelWFX-210
Instrument TypeFlame and Graphite Furnace AAS
MonochromatorPlane Grating
Optical SystemSingle-Beam
DetectorPhotomultiplier Tube (PMT)
ResolutionResolves Mn 279.5 nm and 279.8 nm doublet with valley energy <36%
SensitivityFlame mode — Cu: 0.04 µg/mL per 1% absorption
Graphite furnace mode — Cd≤0.9 pg
Precision (RSD)Flame mode ≤0.9%
Detection LimitFlame mode — Cu: 0.007 µg/mL
Graphite furnace mode — Cd≤4.0 pg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Ruili
OriginBeijing, China
ModelWFX-200
Instrument TypeDual-mode Flame/Graphite Furnace AAS
MonochromatorPlane Grating
Optical SystemSingle-beam
DetectorPhotomultiplier Tube (PMT)
Spectral ResolutionResolves Mn 279.5 nm and 279.8 nm doublet with valley energy <36%
SensitivityFlame mode — Cu: 0.04 µg/mL per 1% absorption
Graphite furnace mode — Cd≤0.9 pg
Precision (RSD)Flame mode ≤0.9%
Detection LimitFlame mode — Cu: 0.007 µg/mL
Graphite furnace mode — Cd≤4.0 pg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRayleigh
OriginBeijing, China
ModelWQF-600N
Instrument PrincipleFourier Transform (FT)
Wavenumber Range3300–10000 cm⁻¹
Spectral Resolution< 4 cm⁻¹
Wavenumber AccuracyBetter than half the set resolution
Transmittance Repeatability±0.5% T
Signal-to-Noise Ratio (S/N)>10,000:1 (RMS, 32 scans at 4300–4400 cm⁻¹)
Beam SplitterCaF₂
Detector OptionsDTGS (PbS, InGaAs optional)
Light SourceAir-cooled tungsten-halogen lamp
Data SystemPC-based with Windows OS
SoftwareFull-featured FT-NIR acquisition, preprocessing, chemometric modeling, and spectral analysis suite compliant with ASTM E1655 and ISO 12099
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Ruili
OriginBeijing, China
ModelSP-3420A
Temperature Control RangeAmbient +12 °C to 400 °C
Maximum Oven Ramp Rate>35 °C/min (100 °C to 200 °C in <3 min)
Injector Maximum Temperature400 °C
Injector Pressure Setting Range0–0.6 MPa
Compatible DetectorsTCD, FID, ECD, FPD, TSD
Injection SystemsPacked Column Injector, Split/Splitless Capillary Injector
Method Storage Capacity4 pre-programmed methods
Diagnostic CapabilityReal-time self-diagnostic with fault localization
Safety ProtectionsTCD carrier-gas failure protection, overtemperature shutdown, FPD light-leak detection
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Ruili
OriginBeijing, China
ModelVIS-723N
Optical SystemSingle-beam
DetectorSilicon photodiode array
Wavelength Range320–1100 nm
Wavelength Accuracy±0.5 nm
Spectral Bandwidth1.0, 2.0, or 5.0 nm (user-selectable fixed settings)
Stray Light≤0.05% T (at 220 nm using NaI solution
Wavelength ScanningMotorized automatic wavelength drive
Dimensions530 × 420 × 205 mm
Weight18 kg
Power SupplyAC 220 V/50 Hz or 110 V/60 Hz
Power Consumption140 W
Interface OptionsRS-232 (RS-485 and USB available on request)
Data StorageNon-volatile memory for method parameters and measurement results
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Ruili
OriginBeijing, China
ModelFR60
Instrument TypePortable Hybrid FTIR-Raman Spectrometer
IR Wavenumber Range4200–650 cm⁻¹
Raman Wavenumber Range175–2800 cm⁻¹
IR Resolution< 4 cm⁻¹
Raman Resolution< 10 cm⁻¹
Scan SpeedFull-spectrum acquisition in ≤ 5 seconds
Signal-to-Noise Ratio (SNR)> 2000:1 (IR, 100 scans)
Wavenumber Accuracy< ±0.1 cm⁻¹ at 2000 cm⁻¹
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Ruili
OriginBeijing, China
ModelWFX-910
Optical SystemSingle-beam
Detector TypeSolid-state CCD detector
Atomizer TypeResistive-heated filament atomizer
Power Consumption~6% of conventional graphite furnace systems
Dimensions (H×W×D)335 mm × 610 mm × 230 mm
Weight18 kg
ComplianceDesigned for field-deployable environmental monitoring per ISO 8288, EPA Method 7000B principles
SoftwareEmbedded acquisition and quantification interface with calibration curve generation and QC flagging
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Ruili
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelSP-3500
Price RangeUSD 14,000–21,000 (FOB)
Instrument TypeLaboratory Gas Chromatograph
Application ScopeGeneral-Purpose
Oven Temperature Range5°C above ambient to 450°C
Maximum Ramp Rate50°C/min
Carrier Gas Flow Control0–1000 mL/min (H₂)
Carrier Gas Pressure Control0–100 psi
Injector Maximum Operating Temperature400°C
Injector Pressure Setting Range0–100 psi
Injector Total Flow Setting Range0–1000 mL/min (H₂)