BrandBeifen Ruili
OriginBeijing, China
ModelWFX-810
Instrument TypeFlame and Graphite Furnace AAS
MonochromatorPlane Grating
Optical SystemDouble-Beam
DetectorPhotomultiplier Tube (PMT)
ResolutionResolves Mn 279.5 nm and 279.8 nm doublet with valley energy < 36%
SensitivityFlame mode — Cu 0.13 µg/mL per 1% absorption
Repeatability (RSD)Flame RSD ≤ 0.9%
Detection LimitFlame — Cu 0.010 µg/mL
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Ruili
OriginBeijing, China
ModelAES-8000 Series
Instrument TypeBenchtop Direct-Reading Spectrometer
Excitation SourceAC/DC Arc
DetectorUV-Sensitive CMOS Array
Focal Length600 mm
Grating Grooves2400 lines/mm
Wavelength Range230–340 nm
Spectral CoverageFull-Spectrum Acquisition
Optical DesignVertical Symmetric Ebert-Fastie
Reciprocal Linear Dispersion0.64 nm/mm (1st order)
Theoretical Spectral Resolution0.003 nm @ 300 nm
Spectrometer Chamber Temperature Control35 °C ± 0.1 °C
Arc Current Range2–20 A (AC), 2–15 A (DC)
Dimensions (L×W×H)1500 × 820 × 650 mm
Weight~180 kg
Operating Environment15–30 °C, RH < 80 %
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Ruili
OriginBeijing, China
ModelUV-2200
Optical DesignDouble-beam
DetectorPhotodiode Array (PDA)
Wavelength Range190–1100 nm
Wavelength Accuracy±0.25 nm
Spectral Bandwidth0.1 / 0.2 / 0.5 / 1.0 / 2.0 / 5.0 nm (6-step selectable)
Stray Light≤0.001% T (at 220 nm using NaI solution
Wavelength Scanning Resolution0.02 nm minimum sampling interval
Power SupplyAC 220 V / 50 Hz
Power Consumption400 W
Dimensions (W×D×H)730 × 530 × 230 mm
Net Weight40 kg
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (PRC)
ModelWQF-520
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Ruili
OriginBeijing, China
ModelUV-9600
Optical SystemSingle-beam
DetectorPhotodiode Array
Wavelength Range190–1100 nm
Wavelength Accuracy±2.0 nm
Spectral Bandwidth1.0, 2.0, 4.0, 5.0 nm (selectable)
Stray Light≤0.05% T (at 220 nm with NaI
Display16×2 LCD
Light SourcesPlug-in deuterium lamp (optional), plug-in tungsten-halogen lamp
Power SupplyAC 220 V/50 Hz or 110 V/60 Hz
Power Consumption120 W
Dimensions (W×D×H)530 × 410 × 210 mm
Net Weight16 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Ruili
OriginBeijing, China
ModelAF3000
Instrument TypeMulti-channel Atomic Fluorescence Spectrometer
Sample IntroductionPeristaltic Pump
Detectable ElementsAs, Sb, Bi, Se, Te, Pb, Sn, Hg, Cd, Ge, Zn, Au, Ag, Co, Cu, Ni
Relative Standard Deviation (RSD)< 0.7%
Linear Dynamic Range> 3 orders of magnitude
Detection LimitsAs, Sb, Bi, Se, Te, Pb, Sn < 0.01 µg/L
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Ruili
OriginBeijing, China
ModelWFX-320
Instrument TypeFlame AAS
MonochromatorPlane Grating
Optical SystemSingle-beam
DetectorPhotomultiplier Tube (PMT)
ResolutionResolves Mn 279.5 nm and 279.8 nm doublet with valley energy <36%
SensitivityCu 0.04 µg/mL per 1% absorption
Repeatability (RSD)≤0.9% (flame mode)
Detection LimitCu 0.007 µg/mL (flame mode)
Optional AccessoryHydride Generation System
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Ruili
OriginBeijing, China
ModelAF-640A
Instrument TypeMulti-channel Atomic Fluorescence Spectrometer
Sample IntroductionPeristaltic Pump
Detectable ElementsAs, Sb, Bi, Se, Te, Pb, Sn, Hg, Cd, Ge, Zn, Au (12 elements)
Relative Standard Deviation (RSD)<1%
Linear Dynamic Range>3 orders of magnitude
Detection LimitsAs, Sb, Bi, Se, Te, Pb, Sn: <0.01 µg/L
Hg, Cd<0.001 µg/L
Ge<0.05 µg/L
Zn<1.0 µg/L
Au<3.0 µg/L
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Ruili
OriginBeijing, China
ModelUV-2601
Optical DesignDual-beam
DetectorPhotodiode Array
Wavelength Range190–1100 nm
Wavelength Accuracy±0.3 nm
Spectral Bandwidth0.5–5.0 nm (5 selectable steps)
Stray Light≤0.1% T (at 220 nm using NaI
Display6-inch high-brightness blue LCD
Light SourcesSocket-type deuterium lamp and tungsten-halogen lamp
Power SupplyAC 220 V/50 Hz or 110 V/60 Hz
Power Consumption200 W
Dimensions (W×D×H)630 × 470 × 210 mm
Net Weight26 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Ruili
OriginBeijing, China
ModelUV-1601
Optical DesignPseudo-Double-Beam
DetectorPhotodiode Array (PDA)
Wavelength Range190–1100 nm
Wavelength Accuracy±0.3 nm
Spectral Bandwidth0.5 / 1.0 / 2.0 / 4.0 / 5.0 nm (5-step selectable)
Stray Light≤0.1% T (at 220 nm with NaI
Auto Wavelength ScanningYes
Dimensions630 × 470 × 210 mm
Weight26 kg
Power SupplyAC 220 V/50 Hz or 110 V/60 Hz
Power Consumption180 W
InterfaceUSB port, optional PC control, printer output
Data RetentionNon-volatile memory for parameters and measurements
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Ruili
OriginBeijing, China
ModelWFX-210
Instrument TypeFlame and Graphite Furnace AAS
MonochromatorPlane Grating
Optical SystemSingle-Beam
DetectorPhotomultiplier Tube (PMT)
ResolutionResolves Mn 279.5 nm and 279.8 nm doublet with valley energy <36%
SensitivityFlame mode — Cu: 0.04 µg/mL per 1% absorption
Graphite furnace mode — Cd≤0.9 pg
Precision (RSD)Flame mode ≤0.9%
Detection LimitFlame mode — Cu: 0.007 µg/mL
Graphite furnace mode — Cd≤4.0 pg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Ruili
OriginBeijing, China
ModelWFX-200
Instrument TypeDual-mode Flame/Graphite Furnace AAS
MonochromatorPlane Grating
Optical SystemSingle-beam
DetectorPhotomultiplier Tube (PMT)
Spectral ResolutionResolves Mn 279.5 nm and 279.8 nm doublet with valley energy <36%
SensitivityFlame mode — Cu: 0.04 µg/mL per 1% absorption
Graphite furnace mode — Cd≤0.9 pg
Precision (RSD)Flame mode ≤0.9%
Detection LimitFlame mode — Cu: 0.007 µg/mL
Graphite furnace mode — Cd≤4.0 pg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRayleigh
OriginBeijing, China
ModelWQF-600N
Instrument PrincipleFourier Transform (FT)
Wavenumber Range3300–10000 cm⁻¹
Spectral Resolution< 4 cm⁻¹
Wavenumber AccuracyBetter than half the set resolution
Transmittance Repeatability±0.5% T
Signal-to-Noise Ratio (S/N)>10,000:1 (RMS, 32 scans at 4300–4400 cm⁻¹)
Beam SplitterCaF₂
Detector OptionsDTGS (PbS, InGaAs optional)
Light SourceAir-cooled tungsten-halogen lamp
Data SystemPC-based with Windows OS
SoftwareFull-featured FT-NIR acquisition, preprocessing, chemometric modeling, and spectral analysis suite compliant with ASTM E1655 and ISO 12099
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Ruili
OriginBeijing, China
ModelVIS-723N
Optical SystemSingle-beam
DetectorSilicon photodiode array
Wavelength Range320–1100 nm
Wavelength Accuracy±0.5 nm
Spectral Bandwidth1.0, 2.0, or 5.0 nm (user-selectable fixed settings)
Stray Light≤0.05% T (at 220 nm using NaI solution
Wavelength ScanningMotorized automatic wavelength drive
Dimensions530 × 420 × 205 mm
Weight18 kg
Power SupplyAC 220 V/50 Hz or 110 V/60 Hz
Power Consumption140 W
Interface OptionsRS-232 (RS-485 and USB available on request)
Data StorageNon-volatile memory for method parameters and measurement results
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Ruili
OriginBeijing, China
ModelFR60
Instrument TypePortable Hybrid FTIR-Raman Spectrometer
IR Wavenumber Range4200–650 cm⁻¹
Raman Wavenumber Range175–2800 cm⁻¹
IR Resolution< 4 cm⁻¹
Raman Resolution< 10 cm⁻¹
Scan SpeedFull-spectrum acquisition in ≤ 5 seconds
Signal-to-Noise Ratio (SNR)> 2000:1 (IR, 100 scans)
Wavenumber Accuracy< ±0.1 cm⁻¹ at 2000 cm⁻¹
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Ruili
OriginBeijing, China
ModelWFX-910
Optical SystemSingle-beam
Detector TypeSolid-state CCD detector
Atomizer TypeResistive-heated filament atomizer
Power Consumption~6% of conventional graphite furnace systems
Dimensions (H×W×D)335 mm × 610 mm × 230 mm
Weight18 kg
ComplianceDesigned for field-deployable environmental monitoring per ISO 8288, EPA Method 7000B principles
SoftwareEmbedded acquisition and quantification interface with calibration curve generation and QC flagging
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Ruili
OriginBeijing, China
ModelUV-1801
Optical SystemSingle-beam
DetectorPhotodiode Array
Wavelength Range190–1100 nm
Wavelength Accuracy±0.5 nm
Spectral Bandwidth1.0, 2.0, or 5.0 nm (user-selectable)
Stray Light≤0.05% T (at 220 nm with NaI solution
Display6-inch high-brightness blue LCD
Light SourcesImported deuterium lamp and tungsten-halogen lamp
Power SupplyAC 220 V/50 Hz or 110 V/60 Hz
Power Consumption140 W
Dimensions (W×D×H)530 × 420 × 205 mm
Net Weight18 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Ruili
OriginBeijing, China
ModelPAF-1100
Instrument TypeSingle-channel Atomic Fluorescence Spectrometer
Sample IntroductionPeristaltic Pump
Detectable ElementsAs, Sb, Bi, Se, Te, Pb, Sn, Hg, Cd, Ge, Zn, Au, Cu, Ag, Co, Ni
Detection LimitsAs ≤ 0.06 µg/L, Hg (Cold Vapor Method) ≤ 0.006 µg/L
Relative Standard Deviation (RSD)As ≤ 1.5%, Hg (Cold Vapor Method) ≤ 1.5%
Linear Dynamic Range> 3 orders of magnitude
Linearity (r)≥ 0.999 for As (0.5–50 µg/L) and Hg (0.05–5 µg/L)
Drift≤ 2% over 30 min
Noise≤ 2% over 30 min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Ruili
OriginBeijing, China
ModelWQF-530A
Instrument TypeLaboratory FTIR Spectrometer
Wavenumber Range350–7800 cm⁻¹
Resolution<0.85 cm⁻¹ (upgradable to ≤0.4 cm⁻¹)
Signal-to-Noise Ratio (S/N)>20,000:1 (upgradable to 55,000:1)
Wavenumber Accuracy<0.1 cm⁻¹
DetectorDLATGS (Deuterated Triglycine Sulfate) with Temperature Stabilization
Scan SpeedMicroprocessor-controlled, user-selectable
Data InterfaceEthernet (RJ-45), USB 2.0
Software Compliance21 CFR Part 11-ready audit trail, electronic signature support
Operating System CompatibilityWindows 10/11 (64-bit)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Ruili
OriginBeijing, China
ModelOILA-I
Instrument TypeBenchtop
Excitation MethodArc
Detector TypeCMOS
Focal Length400 mm
Grating Grooves2400 lines/mm
Wavelength Range201–810 nm
Detection ModeFull-Spectrum Simultaneous Acquisition
Argon ConsumptionNone
Detector ResolutionHigh-Density CMOS Array with Pixel-Level Spectral Sampling
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Ruili
OriginBeijing, China
ModelWFX-220A
Instrument TypeFlame and Graphite Furnace AAS
MonochromatorPlane Grating
Optical SystemSingle-beam
DetectorPhotomultiplier Tube (PMT)
Background CorrectionDeuterium Lamp + Self-absorption Method
Spectral Bandwidth0.2 nm ± 0.02 nm (at 0.2 nm setting)
SensitivityFlame mode — Cu ≤0.03 µg/mL/1%
Precision (RSD)Flame mode — Cu ≤0.5%
Detection LimitFlame mode — Cu ≤0.003 µg/mL
Baseline Stability≤0.002 absorbance units/30 min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Ruili
OriginBeijing, China
ModelWQF-520A
Instrument TypeLaboratory FTIR Spectrometer
Wavenumber Range7800–350 cm⁻¹
Spectral ResolutionBetter than 0.5 cm⁻¹
Scan Velocity2 mm/s (optical path difference rate)
Signal-to-Noise Ratio>15,000:1 (at 4 cm⁻¹, 1 min scan, peak-to-peak)
Dimensions540 × 515 × 260 mm
Weight28 kg
InterfaceUSB 2.0
Light SourceHigh-intensity air-cooled infrared source with spherical reflector
DetectorStandard DTGS or optional MCT (configurable)
Environmental ProtectionHermetically sealed Michelson interferometer with desiccant-view window
Software PlatformWindows-based native Chinese GUI with spectral library management, quantitative analysis, and GLP-compliant reporting modules
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0