BrandBeifen Ruili
OriginBeijing, China
ModelSP-2110
Instrument TypeDedicated Gas Chromatograph for Dissolved Gas Analysis (DGA) in Transformer Oil
ComplianceDesigned to meet GB/T 17623–2017, DL/T 703–2015, and IEC 60567 requirements
InterfaceUSB 2.0
Data AcquisitionIntegrated with Transformer Oil DGA-Specific Chromatography Workstation
Injection SystemManual syringe injection with micro-switch trigger activation
Gas ControlEquipped with digital pressure and mass flow sensors for carrier gas (N₂, H₂, or Ar) and detector gases
Detector ConfigurationDual-TCD (Thermal Conductivity Detector) or TCD+FID (optional)
ColumnPre-packed stainless-steel capillary or packed column optimized for C₁–C₅ hydrocarbons and CO/CO₂ separation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Ruili
OriginBeijing, China
ModelSP-2120
Temperature Control Range20–400 °C above ambient
Ramp Rate0.5–35 °C/min
Cool-down Time<5 min (250 °C → 50 °C)
Carrier Gas Pressure Range & Control0–0.8 MPa
Injector Max Operating Temperature400 °C
Injector Pressure Setting Range0–0.8 MPa
Detection LimitsH₂ ≤5 ppm, CO ≤0.5 ppm, O₂/N₂ ≤0.05 vol%, CH₄/CO₂/C₂H₄/C₂H₆/C₂H₂ ≤0.1 ppm
Total Analysis Time≤7 min (single injection, 9-component full profile)
Simultaneous Active Detectors3 (TCD + dual FID)
Flow Sensors4-channel digital gas flow monitoring
Valve ConfigurationHigh-reliability imported 10-port rotary valve
Explosion Risk AssessmentReal-time calculation per GB/T 20964–2007 and AQ 1018–2006
ComplianceDesigned for GLP-compliant coal mine safety labs
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Ruili
OriginBeijing, China
ModelSY9230
Instrument TypeLaboratory Benchtop Ion Chromatograph
Application ScopeGeneral-Purpose Anion and Cation Analysis
Pump Pressure Range0–35 MPa
Flow Rate Range0–9.999 mL/min
Eluent Flow Rate Accuracy0.1–5.0 mL/min
Max Operating Pressure35 MPa
Column Oven Temperature RangeAmbient +5 °C to 60 °C
Temperature Stability±0.2 °C
Eluent Concentration Range0.1–100 mM
Fluidic Path MaterialFull-PEEK (Polyetheretherketone)
Eluent GenerationOn-Demand Electrolytic Eluent Generator (EG) with Water-Only Input
DegassingIntegrated Low-Pressure Membrane Degasser + Gas-Liquid Separator
Safety FeaturesReal-Time Pressure Monitoring, Leak Detection, Eluent Reservoir Level Sensing, Auto-Shutdown Protocol
Consumables MonitoringColumn & Suppressor Usage Tracking with Auto-Recognition of New Units
Compliance SupportDesigned for GLP/GMP environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Ruili
OriginBeijing, China
ModelSP-5220
Instrument TypeLaboratory Gas Chromatograph
Application ScopeGeneral-Purpose
Regulatory ComplianceCE-marked per EN 61010-1, IEC 61326-1 (EMC), ISO/IEC 17025-compatible operation
Control SystemLinux-based embedded platform with Ethernet and USB 2.0 interfaces
Pressure Control Accuracy±0.001 psi (EPC)
Temperature Program Reproducibility±0.5% (RSD)
MTBF>12,000 hours
Safety CertificationUL 61010-1 / GB 4793.1 compliant
Electromagnetic CompatibilityTested to IEC 61326-1 Class A
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Ruili
OriginBeijing, China
ModelSP-3420A
Temperature Control RangeAmbient +12 °C to 400 °C
Maximum Oven Ramp Rate>35 °C/min (100 °C to 200 °C in <3 min)
Injector Maximum Temperature400 °C
Injector Pressure Setting Range0–0.6 MPa
Compatible DetectorsTCD, FID, ECD, FPD, TSD
Injection SystemsPacked Column Injector, Split/Splitless Capillary Injector
Method Storage Capacity4 pre-programmed methods
Diagnostic CapabilityReal-time self-diagnostic with fault localization
Safety ProtectionsTCD carrier-gas failure protection, overtemperature shutdown, FPD light-leak detection
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Ruili
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelSP-3500
Price RangeUSD 14,000–21,000 (FOB)
Instrument TypeLaboratory Gas Chromatograph
Application ScopeGeneral-Purpose
Oven Temperature Range5°C above ambient to 450°C
Maximum Ramp Rate50°C/min
Carrier Gas Flow Control0–1000 mL/min (H₂)
Carrier Gas Pressure Control0–100 psi
Injector Maximum Operating Temperature400°C
Injector Pressure Setting Range0–100 psi
Injector Total Flow Setting Range0–1000 mL/min (H₂)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Ruili
OriginBeijing, China
ModelSP3400
Temperature Control RangeAmbient +12 °C to 420 °C
Maximum Oven Ramp Rate>33 °C/min (100 °C to 200 °C in <3 min)
Injector Max Operating Temperature420 °C
Injector Pressure Setting Range0–0.6 MPa
Detector OptionsTCD, FID, ECD, FPD, TSD
Injector TypesPacked Column Injector, Split/Splitless Capillary Injector
Method Storage Capacity4 methods
ComplianceDesigned to meet ISO/IEC 17025 operational prerequisites for routine GC analysis
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Ruili
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Regional CategoryDomestic (PRC)
ModelMAS-100
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Ruili
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Product OriginDomestic (PRC)
ModelSP-3510
Price RangeUSD 14,000–21,000 (FOB Beijing)
Instrument TypeLaboratory Gas Chromatograph
Application ScopeGeneral-Purpose
Oven Temperature Range5 °C above ambient to 450 °C
Maximum Ramp Rate50 °C/min
Cooling CapabilityForced-air cooling (no cryogenic option)
Carrier Gas Flow Control Range0–1000 mL/min (H₂)
Carrier Gas Pressure Control Range0–100 psi
Injector Maximum Operating Temperature400 °C
Injector Pressure Setting Range0–150 psi
Injector Total Flow Setting Range0–1000 mL/min (H₂)
Heating Zones9 independent temperature-controlled zones
Simultaneous Inlets/DetectorsUp to 3 inlets and 3 detectors operational concurrently
Detector OptionsFID, TCD, ECD, FPD, TSD, AFD
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Ruili
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Regional ClassificationDomestic (PRC)
ModelSY-9100
Price RangeUSD 14,000–28,000
Instrument TypeConventional HPLC System
Application ScopeGeneral-purpose analytical use
Flow Rate Range0.001–9.999 mL/min (0.001 mL/min increment)
Maximum Operating Pressure42 MPa
Flow Precision<0.1% RSD
Sample Tray Capacity96 positions (1.5 mL vials)
Injection Volume Range1–100 µL
Column Oven Temperature RangeAmbient +5 °C to 100 °C
UV-Vis Wavelength Range190–800 nm
Data Acquisition Frequency50 Hz