Beijing Beifen-Ruili Analytical Instrument (Group) Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Ruili
OriginBeijing, China
ModelWFX-810
Instrument TypeFlame and Graphite Furnace AAS
MonochromatorPlane Grating
Optical SystemDouble-Beam
DetectorPhotomultiplier Tube (PMT)
ResolutionResolves Mn 279.5 nm and 279.8 nm doublet with valley energy < 36%
SensitivityFlame mode — Cu 0.13 µg/mL per 1% absorption
Repeatability (RSD)Flame RSD ≤ 0.9%
Detection LimitFlame — Cu 0.010 µg/mL
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Ruili
OriginBeijing, China
ModelWFX-320
Instrument TypeFlame AAS
MonochromatorPlane Grating
Optical SystemSingle-beam
DetectorPhotomultiplier Tube (PMT)
ResolutionResolves Mn 279.5 nm and 279.8 nm doublet with valley energy <36%
SensitivityCu 0.04 µg/mL per 1% absorption
Repeatability (RSD)≤0.9% (flame mode)
Detection LimitCu 0.007 µg/mL (flame mode)
Optional AccessoryHydride Generation System
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Ruili
OriginBeijing, China
ModelWFX-210
Instrument TypeFlame and Graphite Furnace AAS
MonochromatorPlane Grating
Optical SystemSingle-Beam
DetectorPhotomultiplier Tube (PMT)
ResolutionResolves Mn 279.5 nm and 279.8 nm doublet with valley energy <36%
SensitivityFlame mode — Cu: 0.04 µg/mL per 1% absorption
Graphite furnace mode — Cd≤0.9 pg
Precision (RSD)Flame mode ≤0.9%
Detection LimitFlame mode — Cu: 0.007 µg/mL
Graphite furnace mode — Cd≤4.0 pg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Ruili
OriginBeijing, China
ModelWFX-200
Instrument TypeDual-mode Flame/Graphite Furnace AAS
MonochromatorPlane Grating
Optical SystemSingle-beam
DetectorPhotomultiplier Tube (PMT)
Spectral ResolutionResolves Mn 279.5 nm and 279.8 nm doublet with valley energy <36%
SensitivityFlame mode — Cu: 0.04 µg/mL per 1% absorption
Graphite furnace mode — Cd≤0.9 pg
Precision (RSD)Flame mode ≤0.9%
Detection LimitFlame mode — Cu: 0.007 µg/mL
Graphite furnace mode — Cd≤4.0 pg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Ruili
OriginBeijing, China
ModelWFX-910
Optical SystemSingle-beam
Detector TypeSolid-state CCD detector
Atomizer TypeResistive-heated filament atomizer
Power Consumption~6% of conventional graphite furnace systems
Dimensions (H×W×D)335 mm × 610 mm × 230 mm
Weight18 kg
ComplianceDesigned for field-deployable environmental monitoring per ISO 8288, EPA Method 7000B principles
SoftwareEmbedded acquisition and quantification interface with calibration curve generation and QC flagging
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Ruili
OriginBeijing, China
ModelWFX-220A
Instrument TypeFlame and Graphite Furnace AAS
MonochromatorPlane Grating
Optical SystemSingle-beam
DetectorPhotomultiplier Tube (PMT)
Background CorrectionDeuterium Lamp + Self-absorption Method
Spectral Bandwidth0.2 nm ± 0.02 nm (at 0.2 nm setting)
SensitivityFlame mode — Cu ≤0.03 µg/mL/1%
Precision (RSD)Flame mode — Cu ≤0.5%
Detection LimitFlame mode — Cu ≤0.003 µg/mL
Baseline Stability≤0.002 absorbance units/30 min