| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Model | WFX-810 |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Plane Grating |
| Optical System | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Resolution | Resolves Mn 279.5 nm and 279.8 nm doublet with valley energy < 36% |
| Sensitivity | Flame mode — Cu 0.13 µg/mL per 1% absorption |
| Repeatability (RSD) | Flame RSD ≤ 0.9% |
| Detection Limit | Flame — Cu 0.010 µg/mL |
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Model | WFX-320 |
| Instrument Type | Flame AAS |
| Monochromator | Plane Grating |
| Optical System | Single-beam |
| Detector | Photomultiplier Tube (PMT) |
| Resolution | Resolves Mn 279.5 nm and 279.8 nm doublet with valley energy <36% |
| Sensitivity | Cu 0.04 µg/mL per 1% absorption |
| Repeatability (RSD) | ≤0.9% (flame mode) |
| Detection Limit | Cu 0.007 µg/mL (flame mode) |
| Optional Accessory | Hydride Generation System |
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Model | WFX-210 |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Plane Grating |
| Optical System | Single-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Resolution | Resolves Mn 279.5 nm and 279.8 nm doublet with valley energy <36% |
| Sensitivity | Flame mode — Cu: 0.04 µg/mL per 1% absorption |
| Graphite furnace mode — Cd | ≤0.9 pg |
| Precision (RSD) | Flame mode ≤0.9% |
| Detection Limit | Flame mode — Cu: 0.007 µg/mL |
| Graphite furnace mode — Cd | ≤4.0 pg |
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Model | WFX-200 |
| Instrument Type | Dual-mode Flame/Graphite Furnace AAS |
| Monochromator | Plane Grating |
| Optical System | Single-beam |
| Detector | Photomultiplier Tube (PMT) |
| Spectral Resolution | Resolves Mn 279.5 nm and 279.8 nm doublet with valley energy <36% |
| Sensitivity | Flame mode — Cu: 0.04 µg/mL per 1% absorption |
| Graphite furnace mode — Cd | ≤0.9 pg |
| Precision (RSD) | Flame mode ≤0.9% |
| Detection Limit | Flame mode — Cu: 0.007 µg/mL |
| Graphite furnace mode — Cd | ≤4.0 pg |
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Model | WFX-910 |
| Optical System | Single-beam |
| Detector Type | Solid-state CCD detector |
| Atomizer Type | Resistive-heated filament atomizer |
| Power Consumption | ~6% of conventional graphite furnace systems |
| Dimensions (H×W×D) | 335 mm × 610 mm × 230 mm |
| Weight | 18 kg |
| Compliance | Designed for field-deployable environmental monitoring per ISO 8288, EPA Method 7000B principles |
| Software | Embedded acquisition and quantification interface with calibration curve generation and QC flagging |
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Model | WFX-220A |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Plane Grating |
| Optical System | Single-beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp + Self-absorption Method |
| Spectral Bandwidth | 0.2 nm ± 0.02 nm (at 0.2 nm setting) |
| Sensitivity | Flame mode — Cu ≤0.03 µg/mL/1% |
| Precision (RSD) | Flame mode — Cu ≤0.5% |
| Detection Limit | Flame mode — Cu ≤0.003 µg/mL |
| Baseline Stability | ≤0.002 absorbance units/30 min |