- All
- Favorite
- Popular
- Most rated
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | BCNX-YY08 |
| Price Range | USD 0.14–714 (FOB) |
| Detection Principle | Multi-Parameter Integrated Sensing (Optical Scattering + Semiconductor/PID for NMHC + Dedicated Oil Mist Transduction) |
| Mobility | Fixed Online Installation |
| Application Domain | Commercial Food Service Establishments (Restaurants, Canteens, Street Food Hubs) |
| Measurement Range | 0.0–4.0 mg/m³ |
|---|---|
| Accuracy | ±10% |
| Sampling Cycle | < 1 min |
| Operating Voltage | 220 VAC |
| Power Consumption | 8 W |
| Operating Temperature | –25°C to +75°C |
| Operating Humidity | 5%–95% RH |
| Probe Dimensions | φ45 × 10 mm |
| Data Logger Dimensions | φ45 × 270 mm |
| Startup Time | ~20 s (network-dependent) |
| Controlled Load Rating | 2 kW / 250 V / 10 A per channel |
| Overcurrent Protection | Auto-disconnect after 6 s at threshold exceedance |
| Communication Interfaces | RS485 (sensor), Analog Inputs (status), TCP/IP, CDMA/GPRS/2G, WiFi, LoRa, NB-IoT |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | BCNX-YY08 |
| Price Range | USD 0.14–714 (FOB) |
| Detection Principle | Multi-Parameter Integrated Sensing (Optical Scattering + Semiconductor/PID for NMHC + Dedicated Oil Mist Transduction) |
| Mobility | Fixed Online Installation |
| Application Domain | Commercial Food Service Establishments (Restaurants, Canteens, Street Food Hubs) |
| Oil Mist Measurement Range | 0–30,000 µg/m³ |
| Accuracy | ±10% of reading (vs. reference gravimetric method) |
| Zero Drift | ≤±0.5 mg/m³ over 1 h |
| Relative Error vs. Reference Method | ≤±20% (per HJ 629–2011 & DB11/1488–2018) |
| Linearity Error | ≤10% |
| Insulation Resistance | ≥20 MΩ |
| Withstand Voltage | No arcing or dielectric breakdown at rated test voltage |
| Sampling Cycle | 60 s |
| Operating Voltage | 220 VAC ±10% |
| Power Consumption | 8 W |
| Operating Temperature | 0–70 °C |
| Operating Humidity | 5–95% RH (non-condensing) |
| Probe Dimensions | Ø24 × 248 mm (installation bore: Ø25–26 mm) |
| PM Measurement | Optical scattering principle |
| Resolution | 1 µg/m³ |
| Range | 0–20 mg/m³ (configurable variants: 0–10 mg/m³ or 0–2000 mg/m³) |
| NMHC Measurement | Dual-mode selectable — Metal Oxide Semiconductor (MOS) or Photoionization Detector (PID) |
| Range | 0–30 ppm or 0–1000 ppm |
| Resolution | 0.1 ppm (PID), 1 ppm (MOS) |
| Control Outputs | 4-channel dry-contact relay interface for fan/purifier status monitoring and remote switching |
| Overcurrent Protection | Automatic cut-off after 6 s if load current exceeds threshold |
| Data Reporting Interval | User-configurable (1–3600 s) |
Show next