Empowering Scientific Discovery

Beijing Bocnuo Xin Technology Development Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (PRC)
ModelBCNX-YY08
Price RangeUSD 0.14–714 (FOB)
Detection PrincipleMulti-Parameter Integrated Sensing (Optical Scattering + Semiconductor/PID for NMHC + Dedicated Oil Mist Transduction)
MobilityFixed Online Installation
Application DomainCommercial Food Service Establishments (Restaurants, Canteens, Street Food Hubs)
Added to wishlistRemoved from wishlist 0
Add to compare
Measurement Range0.0–4.0 mg/m³
Accuracy±10%
Sampling Cycle< 1 min
Operating Voltage220 VAC
Power Consumption8 W
Operating Temperature–25°C to +75°C
Operating Humidity5%–95% RH
Probe Dimensionsφ45 × 10 mm
Data Logger Dimensionsφ45 × 270 mm
Startup Time~20 s (network-dependent)
Controlled Load Rating2 kW / 250 V / 10 A per channel
Overcurrent ProtectionAuto-disconnect after 6 s at threshold exceedance
Communication InterfacesRS485 (sensor), Analog Inputs (status), TCP/IP, CDMA/GPRS/2G, WiFi, LoRa, NB-IoT
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (PRC)
ModelBCNX-YY08
Price RangeUSD 0.14–714 (FOB)
Detection PrincipleMulti-Parameter Integrated Sensing (Optical Scattering + Semiconductor/PID for NMHC + Dedicated Oil Mist Transduction)
MobilityFixed Online Installation
Application DomainCommercial Food Service Establishments (Restaurants, Canteens, Street Food Hubs)
Oil Mist Measurement Range0–30,000 µg/m³
Accuracy±10% of reading (vs. reference gravimetric method)
Zero Drift≤±0.5 mg/m³ over 1 h
Relative Error vs. Reference Method≤±20% (per HJ 629–2011 & DB11/1488–2018)
Linearity Error≤10%
Insulation Resistance≥20 MΩ
Withstand VoltageNo arcing or dielectric breakdown at rated test voltage
Sampling Cycle60 s
Operating Voltage220 VAC ±10%
Power Consumption8 W
Operating Temperature0–70 °C
Operating Humidity5–95% RH (non-condensing)
Probe DimensionsØ24 × 248 mm (installation bore: Ø25–26 mm)
PM MeasurementOptical scattering principle
Resolution1 µg/m³
Range0–20 mg/m³ (configurable variants: 0–10 mg/m³ or 0–2000 mg/m³)
NMHC MeasurementDual-mode selectable — Metal Oxide Semiconductor (MOS) or Photoionization Detector (PID)
Range0–30 ppm or 0–1000 ppm
Resolution0.1 ppm (PID), 1 ppm (MOS)
Control Outputs4-channel dry-contact relay interface for fan/purifier status monitoring and remote switching
Overcurrent ProtectionAutomatic cut-off after 6 s if load current exceeds threshold