Empowering Scientific Discovery

Beijing Bocnuo Xin Technology Development Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (PRC)
ModelBCNX-YY08
Price RangeUSD 0.14–714 (FOB)
Detection PrincipleMulti-Parameter Integrated Sensing (Optical Scattering + Semiconductor/PID for NMHC + Dedicated Oil Mist Transduction)
MobilityFixed Online Installation
Application DomainCommercial Food Service Establishments (Restaurants, Canteens, Street Food Hubs)
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelBCNX
Price RangeUSD 1,400 – 7,000 (FOB)
Measurement PrincipleBeta Attenuation + Laser Scattering Hybrid Method
Measured ParametersTSP, PM₁₀, PM₂.₅, PM₁
Measurement Ranges0–1000 µg/m³, 0–2000 µg/m³, 0–10 mg/m³, 0–20 mg/m³ (field-selectable)
Sampling Flow Rate16.7 L/min (standard), configurable up to 30 L/min
Detection Limit≤2 µg/m³ (PM₂.₅, 1-hour average, ISO 12103-1 A2 dust reference)
Flow Stability±2% over 24 h (at 25°C, 1 atm, with integrated mass flow controller)
ComplianceDesigned per HJ 653–2013, HJ 93–2013, and GB 3095–2012
supports audit-ready data logging per EPA 40 CFR Part 58 Appendix A & ISO/IEC 170252017 requirements
Added to wishlistRemoved from wishlist 0
Add to compare
Measurement Range0.0–4.0 mg/m³
Accuracy±10%
Sampling Cycle< 1 min
Operating Voltage220 VAC
Power Consumption8 W
Operating Temperature–25°C to +75°C
Operating Humidity5%–95% RH
Probe Dimensionsφ45 × 10 mm
Data Logger Dimensionsφ45 × 270 mm
Startup Time~20 s (network-dependent)
Controlled Load Rating2 kW / 250 V / 10 A per channel
Overcurrent ProtectionAuto-disconnect after 6 s at threshold exceedance
Communication InterfacesRS485 (sensor), Analog Inputs (status), TCP/IP, CDMA/GPRS/2G, WiFi, LoRa, NB-IoT
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (PRC)
ModelBCNX-YY08
Price RangeUSD 0.14–714 (FOB)
Detection PrincipleMulti-Parameter Integrated Sensing (Optical Scattering + Semiconductor/PID for NMHC + Dedicated Oil Mist Transduction)
MobilityFixed Online Installation
Application DomainCommercial Food Service Establishments (Restaurants, Canteens, Street Food Hubs)
Oil Mist Measurement Range0–30,000 µg/m³
Accuracy±10% of reading (vs. reference gravimetric method)
Zero Drift≤±0.5 mg/m³ over 1 h
Relative Error vs. Reference Method≤±20% (per HJ 629–2011 & DB11/1488–2018)
Linearity Error≤10%
Insulation Resistance≥20 MΩ
Withstand VoltageNo arcing or dielectric breakdown at rated test voltage
Sampling Cycle60 s
Operating Voltage220 VAC ±10%
Power Consumption8 W
Operating Temperature0–70 °C
Operating Humidity5–95% RH (non-condensing)
Probe DimensionsØ24 × 248 mm (installation bore: Ø25–26 mm)
PM MeasurementOptical scattering principle
Resolution1 µg/m³
Range0–20 mg/m³ (configurable variants: 0–10 mg/m³ or 0–2000 mg/m³)
NMHC MeasurementDual-mode selectable — Metal Oxide Semiconductor (MOS) or Photoionization Detector (PID)
Range0–30 ppm or 0–1000 ppm
Resolution0.1 ppm (PID), 1 ppm (MOS)
Control Outputs4-channel dry-contact relay interface for fan/purifier status monitoring and remote switching
Overcurrent ProtectionAutomatic cut-off after 6 s if load current exceeds threshold
Data Reporting IntervalUser-configurable (1–3600 s)
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelUAV-Mounted Integrated Sensor Payload
Price RangeUSD 140,000 – 210,000
Product CategoryAtmospheric Heavy Metal & Particulate Matter Online Analyzer
Measurement PrincipleLaser Scattering (PM), Electrochemical (SO₂, NO₂, CO, O₃), Photoionization (VOC), Optical Absorption (optional heavy metal speciation via integrated micro-XRF or LIBS module*)
Measurement RangeTSP, PM₁₀ (0–1999 µg/m³), PM₂.₅ (0–999 µg/m³), O₃/SO₂/NO₂ (0–1 ppm), CO (0–200 ppm), VOC (0–50 ppm)
Detection Limit1–10 ppb (gas species)
Filter Replacement Interval30 days (under typical urban ambient conditions)
Operating Temperature−30 °C to +60 °C
Operating Humidity15–95% RH (non-condensing)
Ambient Pressure Range80–106 kPa
Power Supply12–24 V DC
Weight950 g (7-parameter standard configuration)
Dimensions220 × 145 × 60 mm
Battery Endurance≥10 h continuous operation (with onboard LiPo power management)
Data TransmissionDual-mode GPRS + 2.4 GHz RF telemetry (AES-128 encrypted)
ComplianceISO 9001-certified manufacturing
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0