Empowering Scientific Discovery

Beijing Bolun Jingwei Technology Development Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandApogee
OriginUSA
ModelSU-200-SS / SU-202-SS / SU-205-SS
Spectral Range300–400 nm
Output Types0–10 mV (SU-200-SS), 0–2.5 V (SU-202-SS), 0–5 V (SU-205-SS)
Calibration UnitW·m⁻² (irradiance)
Measurement Range0–100 W·m⁻²
Spectral Bandwidth300–400 nm
Wavelength Accuracy±5%
Stray Light Rejection±1%
Operating Temperature−35 to +85 °C
Relative Humidity Range0–100% RH
Housing IP RatingIP68
Cable Length5 m
Sensor Diameter × HeightΦ30.5 × 37 mm
Weight140 g
Long-Term Drift<2% per year
Nonlinearity<1%
Directional Response±2% at 45°, ±5% at 75°
Temperature Coefficient0.1% / °C
Calibration Uncertainty±10%
Added to wishlistRemoved from wishlist 0
Add to compare
BrandApogee
OriginUSA
ModelSP-110 / SP-212 / SP-214 / SP-215 / SP-230
Output TypesmV (SP-110, SP-230), 0–2.5 V (SP-212), 4–20 mA (SP-214), 0–5 V (SP-215)
Spectral Range360–1120 nm
Field of View180°
Sensitivity0.2 mV/(W·m⁻²) (SP-110, SP-230), 2.0 mV/(W·m⁻²) (SP-212), 0.013 mA/(W·m⁻²) (SP-214), 4.0 mV/(W·m⁻²) (SP-215)
Calibration Uncertainty±5%
Nonlinearity<1% (0–1250 or 0–1750 W·m⁻², model-dependent)
Response Time<1 ms
Directional Error @75°±5%
Temperature Response−0.04 ± 0.04 %/°C
Operating Environment−40 to +70 °C, 0–100 % RH
Long-Term Drift<2 %/year
Repeatability<1%
Housing DimensionsØ24 mm × 28 mm
Weight (with 5 m cable)90 g (SP-110, SP-212, SP-215, SP-230), 140 g (SP-214)
Warranty4 years
Added to wishlistRemoved from wishlist 0
Add to compare
BrandApogee
OriginUSA
ModelPS-200
Spectral Range190–850 nm
Calibration Wavelength Range300–850 nm
Wavelength Resolution0.85 nm
Detector2048-pixel CCD
Grating Density590 lines/mm
A/D Conversion16-bit
Signal-to-Noise Ratio1000:1
Stray Light0.02% at 435 nm
Repeatability<1%
Radiometric Accuracy±10%
Integration Time1 ms – 65 s
Angular Response (up to 80°)±5%
InterfaceUSB 2.0
Power Supply5 V DC / 100 mA via USB
Operating Temperature0–60 °C
Optical Fiber Length2 m
Dimensions69 × 100 × 150 mm
Weight900 g
Added to wishlistRemoved from wishlist 0
Add to compare
BrandApogee
OriginUSA
ModelMU-100 / MU-200
Spectral Range250–400 nm
UVA Range315–400 nm
UVB Range280–315 nm
Output Unitsμmol·m⁻²·s⁻¹ and W·m⁻²
Calibration Uncertainty±10%
Repeatability<1%
Long-Term Drift<3% per year
Nonlinearity<1% (up to 300 μmol·m⁻²·s⁻¹)
Response Time<1 ms
Field of View180°
Directional Response±10% at 75° zenith angle
Temperature Dependence~0.1%/°C
Operating Environment0–50°C, ≤90% RH non-condensing
Probe IP RatingIP68 (MU-200 probe, 30 m submersible)
Data LoggingManual (99 points) or Automatic (30 s sampling interval, 30 min averaging, 99 daily means)
PowerCR2320 coin cell (MU-100)
Dimensions (Meter)126 × 70 × 24 mm
Weight (Meter only)150 g (MU-100), 180 g (MU-200 body)
Cable Length (MU-200)2 m
AccessoriesAC-100 USB interface cable, AM-310/AM-320 telescoping probe handles, AL-100/AL-210 leveling mounts with bubble vials and three-point adjustment
Added to wishlistRemoved from wishlist 0
Add to compare
BrandApogee
OriginUSA
Manufacturer TypeAuthorized Distributor
Product OriginImported
ModelCloudburst SG-400 Series
Output InterfaceSDI-12 v1.4 (Modbus option planned)
Capture Area324 cm² (SG-400/SG-410) or 200 cm² (SG-420/SG-430)
Inlet Diameter8 in (20.3 cm) or 6.3 in (16 cm)
Precipitation Capacity900 mm (SG-400/SG-410) or 1500 mm (SG-420/SG-430)
Bucket Volume30 L
Heating OptionOptional (SG-410 & SG-430)
Accuracy (Cumulative)±0.1 mm (<5 mm), ±1% (>5 mm)
Accuracy (Rate)±5% (>2 mm/hr)
Resolution0.01 mm
Temperature Sensitivity±0.01 mm/°C
Long-Term Drift<0.5%/year
Nonlinearity<0.1 mm (SG-400/SG-420), <0.2 mm (SG-410/SG-430)
Sensor TypeStainless Steel Strain-Gauge Load Cell
Power Supply5.5–26 VDC
Current Draw20 mA (non-heated), +2.1 A @24 VDC (heated)
Power Consumption240 mW (base), up to 50 W (heater active)
Operating Temperature–20 to +60 °C
Humidity Range0–100% RH
Enclosure RatingIP67
DimensionsØ38 cm × H80 cm
Weight12 kg
MountingCompatible with 15.24 cm wooden posts or 10.16 cm metal pipes
Cable Length5 m standard
Added to wishlistRemoved from wishlist 0
Add to compare
BrandApogee
OriginUSA
ModelMS100
Spectral Range380–780 nm
Spectral Resolution1 nm
FWHM~12 nm
Wavelength Repeatability±1 nm
PPFD Range0.1–3,500 µmol/m²/s
Illuminance Range5–190,000 lx
Illuminance Accuracy±5 % (Illuminant A, 2856 K, 20,000 lx)
Chromaticity Accuracy±0.0025 in CIE 1931 x,y
CCT Accuracy±2 %
CRI Accuracy±1.5 %
Diffuse Rejection−25 dB
Integration Time6–1,000 ms
Operating Temperature0–35 °C (RH ≤70 %, non-condensing)
Storage Temperature−10–40 °C (RH ≤70 %, non-condensing)
Display0.96″ 128×64 monochrome OLED
Battery700 mAh / 3.7 V rechargeable Li-ion
Weight (with battery)70 g ±5 g
Dimensions90 × 30 × 32.2 mm
Data StoragemicroSDHC up to 32 GB (supports ≥120,000 Excel files)
ConnectivityMini-USB 2.0, Bluetooth 3.0/4.0 (iOS & Android compatible)
SoftwareApogee InSight (Windows, macOS, iOS, Android)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandApogee
OriginUSA
ModelDLI400, DLI500, DLI600
Measurement Wavelength Range400–700 nm (DLI400), 389–692 nm (DLI500), 383–757 nm (DLI600)
Measurement Range0–4000 µmol/m²/s
Resolution1 µmol/m²/s (real-time), 0.1 µmol/m²/s (stored PPFD), 0.1 mol/m²/day (DLI), 0.1 h (photoperiod)
Calibration Uncertainty±5%
Long-term Drift<2%/year
Cosine Response Error±5% up to 75° zenith angle
Field of View180°
Response Time2.5 s
Data Logging Capacity99 days (DLI & photoperiod), 10 days (30-min averaged PPFD/ePPFD)
Operating Temperature–40 to +70 °C (DLI500/DLI600), –10 to +60 °C (DLI400)
IP RatingIP65
Weight67 g
PowerTwo AAA batteries (≈6 months life)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandApogee
OriginUSA
ModelSM500 / SM600
Temperature Range–60 to +80 °C
Temp Accuracy±0.2 °C
Temp Drift<0.02 °C/year
Temp Repeatability<0.01 °C
Temp Response Time7 s
RH Range0–95 %RH
RH Accuracy±3 % @ 20–80 %RH
CO₂ Range0–2000 ppm
CO₂ Accuracy±50 ppm + 2 % of reading
CO₂ Response Time105 s
Barometric Pressure Range70–110 kPa
Spectral Range (SM500)389–692 nm
Spectral Range (SM600)383–757 nm
PAR/ePAR Range0–4000 µmol·m⁻²·s⁻¹
Calibration Uncertainty±5 %
Long-term Instability<2 %/year
Measurement Repeatability<0.5 %
Field of View180°
Directional Response Error±5 % @ 75° zenith angle
Azimuthal Error<0.5 %
Tilt Error<0.5 %
Nonlinearity<1 %
Sensor Response Time1 ms
Temp Coefficient–0.11 % ±0.04 %/°C
Daily Integral Uncertainty<5 %
Power Supply5–30 V DC
Power Consumption1.1–1.5 W
Data Storage9 months of 1-minute intervals
Output InterfacesModbus RTU (RS-232 & RS-485) and Bluetooth 5.0
Operating Environment–40 to +60 °C, 0–100 %RH
Enclosure MaterialWhite ASA plastic
IP RatingIP53
Weight392 g
DimensionsØ105 mm × H157 mm
Cable Length5 m
Added to wishlistRemoved from wishlist 0
Add to compare
BrandApogee
OriginUSA
ModelSQ-500
Power SupplySelf-powered (no external power required)
Sensitivity0.01 mV per μmol·m⁻²·s⁻¹
Calibration Factor100 μmol·m⁻²·s⁻¹ per mV
Absolute Accuracy±5%
Repeatability<1%
Long-term Drift<2% per year
Nonlinearity<1% up to 4000 μmol·m⁻²·s⁻¹
Response Time<1 ms
Field of View180° (cosine-corrected hemispherical)
Spectral Range389–692 nm
Directional Response Error at 75°±5%
Temperature Response−0.11 ± 0.03 %/°C
Operating Environment−40 to +70 °C, 0–100% RH
DimensionsØ24 mm × 35 mm (sensor head)
Weight100 g (sensor with 5 m cable)
Waterproof RatingSubmersible to 30 m
Warranty4 years
Added to wishlistRemoved from wishlist 0
Add to compare
BrandApogee
OriginUSA
ModelSI-111
Operating Wavelength8–14 µm
Field of View22° half-angle
Accuracy±0.2 °C @ −10 to +65 °C
Repeatability±0.05 °C @ 10 to +65 °C
Response Time<1 s
Output60 µV/°C (target), 0–2500 mV (sensor body temperature)
HousingAnodized aluminum with germanium optical window
DimensionsØ23 mm × 60 mm
Weight190 g
Cable4.5 m, 4-conductor shielded
Operating Ambient−55 to +80 °C, 0–100 % RH
Power Supply2.5 V excitation for thermistor
Added to wishlistRemoved from wishlist 0
Add to compare
BrandApogee
OriginUSA
ModelMQ-100 / MQ-200 / MQ-306
Spectral Range410–655 nm
PAR Measurement Range0–3000 µmol/m²/s
Field of View180°
Calibration Uncertainty±5%
Repeatability<1%
Long-Term Drift<2% per year
Nonlinearity<1% (up to 3000 µmol/m²/s)
Response Time<1 ms
Directional (Cosine) Error±5% at 75° zenith angle
Temperature Dependence0.06 ± 0.06 %/°C
Operating Environment0–50 °C, ≤90% RH non-condensing
Waterproof RatingIP68 (MQ-200, MQ-301, MQ-303, MQ-306 probe)
Data LoggingManual (99 samples) or Automatic (30-sec measurement interval, 30-min averaging, 99 daily means)
DisplayIntegrated LCD
InterfaceAC-100 USB cable
PowerCR2320 coin cell (MQ-100/MQ-200), CR2477 (MQ-301/MQ-303/MQ-306)
Dimensions (Meter)125 × 70 × 24 mm
Weight (Meter)150 g (MQ-100), 180 g (MQ-200), 380 g (MQ-301), 300 g (MQ-303/MQ-306)
Probe Count1 (MQ-100/MQ-200), 10 (MQ-301), 3 (MQ-303), 6 (MQ-306)
Probe Cable LengthNone (MQ-100), 2 m or 5 m (MQ-200), 70 cm rod (MQ-301), 50 cm rod (MQ-303/MQ-306)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandApogee
OriginUSA
ModelSN-522-SS / SN-522
Spectral Range (Shortwave, Upward)385–2105 nm
Spectral Range (Shortwave, Downward)295–2685 nm
Spectral Range (Longwave)5–30 µm
Shortwave Measurement Range0–2000 W/m²
Longwave Net Measurement Range−200 to +200 W/m²
Sensitivity (Shortwave, Up)0.045 mV/(W/m²)
Sensitivity (Shortwave, Down)0.035 mV/(W/m²)
Sensitivity (Longwave)0.12 mV/(W/m²)
Calibration Uncertainty (Shortwave)<3% @ 1000 W/m²
Calibration Uncertainty (Longwave)±5%
Output Signal (Shortwave)0–90 mV (up), 0–70 mV (down)
Output Signal (Longwave)−24 to +24 mV
Response Time<0.5 s (analog), 750 ms (digital processing)
Field of View180° (upward shortwave), 150° (downward shortwave & longwave)
Cosine Response Error<30 W/m² at 80° solar zenith (up), <20% from 0–60° (down)
Zero Offset A<5 W/m² (unheated), <10 W/m² (heated)
Zero Offset B<5 W/m²
Nonlinearity<1%
Repeatability<1%
Long-Term Drift<2%/year
Temperature Operating Range−50 to +80 °C
Relative Humidity Range0–100% RH
Power Supply5.5–24 V DC
Current Draw (Heater On, 12 V DC)72 mA
Current Draw (Heater Off, 12 V DC)13.5 mA
Heater Power (per sensor)740 mW @ 12 V DC
Dimensions116 × 45 × 66 mm
Weight320 g (incl. mounting rod and 5 m cable)
Cable5 m shielded twisted-pair, Santoprene jacket, M8 IP68 connector
Integrated Temperature Sensor30 kΩ thermistor, ±1 °C tolerance at 25 °C
Thermistor Output0–2500 mV (typical), excitation voltage 2500 mV (typical)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandApogee
OriginUSA
ModelSQ-420
Spectral Range410–655 nm
Calibration Uncertainty±5%
Repeatability<1%
Long-Term Drift<2% per year
Nonlinearity<1% (up to 3000 µmol·m⁻²·s⁻¹)
Response Time1 s
Directional Error±5% (at 75° zenith angle)
Temperature Dependence0.06 ± 0.06 %/°C
Operating Environment−40 to +70 °C, 0–100% RH
Submersible Depth<30 m
Field of View180°
Resolution0.1 µmol·m⁻²·s⁻¹
Internal Memory Capacity10,000 measurements
Sampling Interval1 s to 1440 min (user-configurable)
Power SupplyUSB 5 VDC
Current Draw5.1 mA
Probe Dimensions60 mm (diameter) × 70 mm (height)
Cable Length4.6 m
Weight90 g
Added to wishlistRemoved from wishlist 0
Add to compare
BrandApogee
OriginUSA
ModelSN-500
Measurement RangeShortwave Up: 0–2000 W/m²
Shortwave Down0–2000 W/m²
Longwave Up–200 to +200 W/m²
Longwave Down–200 to +200 W/m²
Spectral RangeShortwave Up: 385–2105 nm
Shortwave Down295–2685 nm
Longwave Up/Down5000–30,000 nm
Sensitivity55 µV/W/m² (SW Up)
Response Time<1 s (to 95%)
Zero Offset (5 K/h)18.2 W/m² (SW Up)
Field of ViewSW Up: 180°
SW Down150°
LW Up/Down180°
Built-in Temperature SensorPT-100 Platinum RTD
Heater12 V DC
Cable Length5 m
Ingress ProtectionIP67
Output InterfaceSDI-12 (4 independent channels)
Operating Environment–50 °C to +80 °C, 0–100 % RH
Added to wishlistRemoved from wishlist 0
Add to compare
BrandApogee
OriginUSA
ModelSO-110, SO-120, SO-210, SO-220
Measurement Range0–100 % O₂
Output Sensitivity2.6 mV/%O₂ (SO-110/SO-210), 0.6 mV/%O₂ (SO-120/SO-220)
Output at 20.95 %O₂6 mV (SO-110), 3 mV (SO-120), 55 mV (SO-210), 12.5 mV (SO-220)
Repeatability±0.001 %O₂
Nonlinearity<0.01 %O₂
Long-term Drift1 mV/year (SO-110/SO-210), 0.8 mV/year (SO-120/SO-220)
Response Time (t₉₀)60 s (SO-110/SO-120), 14 s (SO-210/SO-220)
Operating Temperature–20 to +60 °C
Relative Humidity Range0–100 % RH
Pressure Range60–140 kPa
Supply Voltage12 V DC (with heater), 2.5 V DC (for thermistor excitation)
Heater Current6.2 mA
Thermistor Excitation Current0.1 mA
Sensor Dimensions32 mm Ø × 68 mm L
Diffusion Probe (optional)35 mm Ø × 35 mm L, 125-mesh stainless steel screen
Flow-through Probe (optional)32 mm Ø × 91 mm L, 0.25″ nylon connector
Housing MaterialAnodized aluminum or polypropylene
Internal Temperature SensorYes, for thermal compensation
Heating ElementIntegrated, prevents membrane condensation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandApogee
OriginUSA
ModelMC-100
Measurement Unitµmol chlorophyll m⁻²
Sampling Area63.6 mm² (9.0 mm diameter) / 19.6 mm² (5.0 mm reduced diameter)
Resolution±10 µmol m⁻²
Linearity±1%
Repeatability±1%
Sampling Time3 s
Memory Capacity94,000 measurements (8 MB internal) + 160,000 GPS-tagged records
Display125 × 37.5 px monochrome LCD
InterfaceUSB + RS-232 (GPS-integrated)
Operating Temperature0–50 °C with full-range thermal compensation
Power9 V DC alkaline battery
Dimensions152 × 82 × 25 mm
Warranty1-year limited warranty, lifetime technical support
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAcclima, Inc.
OriginUSA
ModelSWHMS
Instrument TypeMulti-parameter Soil Monitoring System
ComplianceASTM D5084, ISO 18643, USCRN Protocols, GLP-aligned Data Logging
Power Supply6–17 VDC
CommunicationSDI-12, RS-232/RS-485 (via CR1000X)
Operating Temperature−40 °C to +85 °C
Enclosure RatingIP67/IP68 (sensor-specific)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAcclima, Inc.
OriginUSA
ModelTDR315N
Instrument TypeSoil Moisture / Water Potential Analyzer
Volumetric Water Content Range0–100% VWC
Resolution0.1% VWC
Accuracy±2% FS
Dielectric Constant Range1–100
Resolution0.1
Accuracy±2%
Bulk EC Range0–6000 µS/cm
Pore Water EC (Hilhorst Model)0–55,000 µS/cm
EC Resolution1 µS/cm
EC Accuracy±25 µS/cm (0–1000 µS/cm), ±2.5% (1000–2000 µS/cm), ±5% (2000–5000 µS/cm)
Temperature Range−40 to +60 °C
Temp Accuracy±0.25 °C (5–35 °C), ±0.5 °C (−15 to +50 °C)
Temp Resolution0.1 °C
Rise Time (20–80%)300 ps
Waveform Digitization Resolution5 ps
Input Voltage6.5–15 V DC
Quiescent Current10 µA
Active Current118 mA @ 12 V DC
Output Interface3-wire SDI-12 v1.4 compliant
Probe Dimensions15 mm L × 3.5 mm Ø
Sensor Body210 mm × 53 mm × 20 mm
Weight (bare)105 g
Cable Length5 m standard (10 m optional)
EnclosureWaterproof epoxy-filled housing
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAcclima, Inc.
OriginUSA
ModelTDR305N
Instrument TypeSoil Moisture / Water Potential Analyzer
Volumetric Water Content Range0–100% VWC
Resolution0.1% VWC
Accuracy±2% FS
Repeatability (RMS)0.07% VWC
Dielectric Constant Range1–100
Resolution0.1
Accuracy±2%
Bulk EC Range0–3000 µS/cm
Stability±1% FS
Soil Temperature Range−40 to +60 °C
Resolution0.1 °C
Accuracy±0.25 °C (5–35 °C), ±0.5 °C (−15–50 °C)
Pore Water EC (Hilhorst Model)0–55,000 µS/cm
Volume EC Resolution1 µS/cm
Repeatability3 µS/cm
Accuracy±25 µS/cm (0–1000 µS/cm), ±2.5% (1000–2000 µS/cm), ±5% (2000–5000 µS/cm)
Rise Time (20–80%)300 ps
Waveform Digitization Resolution5 ps
Incident Pulse Amplitude2.3 V
Power Supply6.5–15 V DC
Quiescent Current10 µA
Active Current118 mA @ 12 V DC
Output Interface3-wire SDI-12 v1.4 compliant
Probe Dimensions49.9 mm × Ø3.5 mm
Body Dimensions150 × 33 mm
Weight (no cable)121 g
Standard Cable Length5 m (optional: 10 m)
HousingWaterproof epoxy-filled enclosure
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAcclima, Inc.
OriginUSA
ModelTDR305W
Measurement PrincipleTime-Domain Reflectometry (TDR)
Output Interface3-wire SDI-12 v1.4 compliant
Volumetric Water Content Range0–100% VWC
Resolution0.1% VWC
Accuracy±5% FS
Bulk EC Range0–9000 µS/cm
Pore Water EC (Hilhorst model)0–55,000 µS/cm
EC Accuracy±25 µS/cm (0–1000 µS/cm), ±2.5% (1000–2500 µS/cm), ±5% (2500–6000 µS/cm), ±7.5% (6000–9000 µS/cm)
Dielectric Constant Range1–100
Resolution0.1
Accuracy±4%
Temperature Range−40 to +55 °C
Resolution0.1 °C
Accuracy±0.25 °C (5–35 °C), ±0.5 °C (−15–50 °C)
Waveform Digitization Resolution5 ps
Input Pulse Amplitude2.3 V
HousingWaterproof epoxy-filled enclosure
Power Supply4.2–15 V DC
Quiescent Current<26 µA
Active Current90 mA @ 12 V DC
Dimensions (sensor head)110 × 53 × 20 mm
Probe Length49.55 mm
Probe Diameter3.5 mm
Weight (bare sensor)94 g
Standard Cable Length5 m (optional: 10 m)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAcclima, Inc.
OriginUSA
ModelRD1200
Instrument TypeSoil Moisture / Water Potential Analyzer
Measurement PrinciplesTDR (Time Domain Reflectometry) with Integrated Dielectric, Thermal, and Conductivity Sensing
Soil Volumetric Water Content Range0–100% VWC
Resolution0.1% VWC
Accuracy±1% VWC (coarse-medium soils), ±2.5% VWC (fine-textured soils)
Soil Temperature Range−40 to +60 °C
Resolution0.1 °C
Accuracy±0.25 °C
Dielectric Constant Range1–80
Resolution0.1
Accuracy±1% (coarse-medium), ±2% (fine-textured)
Bulk Electrical Conductivity (ECb)0–5000 μS/cm
Pore Water Electrical Conductivity (ECw)0–55,000 μS/cm
EC Resolution1 μS/cm
EC Accuracy±25 μS/cm (0–1000 μS/cm), ±2.5% (1000–2000 μS/cm), ±5% (2000–5000 μS/cm)
GPS ModuleIntegrated SDI-12-compatible GNSS receiver (latitude, longitude, altitude, UTC time sync)
Data StorageInternal non-volatile memory + USB 2.0 interface supporting up to 25 GB flash drives
Power Supply5 VDC @ 1 A (AC adapter: 100–240 VAC input)
Dimensions150 × 80 × 25 mm
Weight0.3 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAcclima, Inc.
OriginUSA
ModelTDR310W
Sensor TypeTDR-based Volumetric Water Content, Soil Temperature & Bulk Electrical Conductivity Sensor
Measurement PrincipleTime-Domain Reflectometry (TDR) with Ultra-High-Speed Waveform Generation & 5 ps Timebase Resolution
Output Interface3-Wire SDI-12 v1.4 Compliant
Probe Length100 mm
Probe Diameter3.5 mm
HousingWaterproof Epoxy-Filled Enclosure
Power Supply6.5–15 V DC
Quiescent Current10 µA
Active Current118 mA @ 12 V DC
Operating Temperature–40 °C to +60 °C
Cable Length5 m (standard), optional 10 m
Weight94 g (sensor head only)
Dimensions (housing)160 × 53 × 20 mm
Volumetric Water Content Range0–100 % VWC
VWC Resolution0.1 % VWC
VWC Accuracy±2 % FS
VWC Repeatability (RMS)0.07 % VWC
Dielectric Constant Range1–100
Dielectric Resolution0.1
Dielectric Accuracy±2 %
Bulk EC Range0–6000 µS/cm
Bulk EC Resolution1 µS/cm
Bulk EC Accuracy±25 µS/cm (0–1000 µS/cm), ±2.5% (1000–2000 µS/cm), ±5% (2000–5000 µS/cm)
Pore Water EC (Hilhorst model)0–55,000 µS/cm
Soil Temperature Range–40 °C to +60 °C
Temp Resolution0.1 °C
Temp Accuracy±0.25 °C (5–35 °C), ±0.5 °C (–15–50 °C)
Temp Repeatability (RMS)0.01 °C
Rise Time (20–80%)300 ps
Waveform Digitization Resolution5 ps
Incident Pulse Amplitude2.3 V
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAcclima, Inc.
OriginUSA
ModelTDT
Instrument TypeVolumetric Water Content (VWC) and Bulk Electrical Conductivity (EC) Sensor
Measurement PrincipleTime Domain Transmission (TDT)
VWC Range0–100.00% VWC
VWC Resolution0.06% VWC
VWC Accuracy±2% VWC (typical mineral soils)
Bulk EC Range0–5 dS/m
Bulk EC Resolution0.01 dS/m
Bulk EC Accuracy±0.2 dS/m
Bulk EC Stability±1% of full scale (0–5 dS/m)
Soil Temperature Range–20 to +50 °C
Soil Temperature Resolution0.1 °C
Soil Temperature Accuracy±0.3 °C (0–40 °C), ±0.5 °C (–20–0 °C and 40–50 °C)
Response Time450 ms
Power Supply5–15 VDC (12 VDC nominal)
Current Draw84 mA (during measurement burst)
Output ProtocolSDI-12 v1.3
Operating Temperature (in soil)0.5–50 °C (non-frozen conditions)
Storage Temperature–20 to +75 °C
Dimensions20 × 5.33 × 1.5 cm
Weight220 g
Cable Length10 m
Added to wishlistRemoved from wishlist 0
Add to compare
BrandALPHA (USA)
OriginUSA
ModelAIC3Pro
Instrument TypeHandheld
Flow ModeLow-flow Gerdien Tube Design
Repeatability±5%
Accuracy±20%*
Ion Concentration Range0–2×10⁶ ions/cm³ or 0–2×10⁸ ions/cm³ (selectable)
Resolution10 ions/cm³ @ 2×10⁶ range
Polarity ModesUnipolar (Positive/Negative) or Bipolar (with real-time Sum calculation)
Polarity Switching Interval (Bipolar)7.5 s per polarity
Data LoggingTimestamped CSV to removable microSD (up to 32 GB)
Display128×128 px backlit LCD
Battery2000 mAh rechargeable Li-ion (UN38.3 certified)
Operating Environment–20 °C to +43 °C, 0–85% RH (non-condensing), wind <15 km/h
Humidity Sensor Accuracy±2% RH
ComplianceFCC Part 15, CE EMC (BS EN 55032:2015/Cor1:2016
BS EN 61000-3-22019
BS EN 61000-3-32013+A1:2017
BS EN 550352017/A11:2020), RoHS (EN 50581:2012)
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0