Empowering Scientific Discovery

Beijing Bolun Jingwei Technology Development Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandApogee
OriginUSA
ModelDLI400, DLI500, DLI600
Measurement Wavelength Range400–700 nm (DLI400), 389–692 nm (DLI500), 383–757 nm (DLI600)
Measurement Range0–4000 µmol/m²/s
Resolution1 µmol/m²/s (real-time), 0.1 µmol/m²/s (stored PPFD), 0.1 mol/m²/day (DLI), 0.1 h (photoperiod)
Calibration Uncertainty±5%
Long-term Drift<2%/year
Cosine Response Error±5% up to 75° zenith angle
Field of View180°
Response Time2.5 s
Data Logging Capacity99 days (DLI & photoperiod), 10 days (30-min averaged PPFD/ePPFD)
Operating Temperature–40 to +70 °C (DLI500/DLI600), –10 to +60 °C (DLI400)
IP RatingIP65
Weight67 g
PowerTwo AAA batteries (≈6 months life)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandApogee
OriginUSA
ModelSN-500
Measurement RangeShortwave Up: 0–2000 W/m²
Shortwave Down0–2000 W/m²
Longwave Up–200 to +200 W/m²
Longwave Down–200 to +200 W/m²
Spectral RangeShortwave Up: 385–2105 nm
Shortwave Down295–2685 nm
Longwave Up/Down5000–30,000 nm
Sensitivity55 µV/W/m² (SW Up)
Response Time<1 s (to 95%)
Zero Offset (5 K/h)18.2 W/m² (SW Up)
Field of ViewSW Up: 180°
SW Down150°
LW Up/Down180°
Built-in Temperature SensorPT-100 Platinum RTD
Heater12 V DC
Cable Length5 m
Ingress ProtectionIP67
Output InterfaceSDI-12 (4 independent channels)
Operating Environment–50 °C to +80 °C, 0–100 % RH
Added to wishlistRemoved from wishlist 0
Add to compare
BrandApogee
OriginUSA
ModelMC-100
Measurement Unitµmol chlorophyll m⁻²
Sampling Area63.6 mm² (9.0 mm diameter) / 19.6 mm² (5.0 mm reduced diameter)
Resolution±10 µmol m⁻²
Linearity±1%
Repeatability±1%
Sampling Time3 s
Memory Capacity94,000 measurements (8 MB internal) + 160,000 GPS-tagged records
Display125 × 37.5 px monochrome LCD
InterfaceUSB + RS-232 (GPS-integrated)
Operating Temperature0–50 °C with full-range thermal compensation
Power9 V DC alkaline battery
Dimensions152 × 82 × 25 mm
Warranty1-year limited warranty, lifetime technical support
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKipp & Zonen
OriginNetherlands
ModelCMP6
ISO 90601990 Classification: First Class
Spectral Range (50% points)285–2800 nm
Thermal Offset (at 200 W/m²)<12 W/m²
Temperature Response Drift<4% (−10 °C to +40 °C)
Non-stability (annual)<1%
Non-linearity (100–1000 W/m²)<1%
Tilt Error (0–90°, 1000 W/m²)<1%
Leveling Accuracy<0.1°
Response Time (63%)<6 s
Response Time (95%)<18 s
Max. Irradiance2000 W/m²
Sensitivity5–20 µV/W/m²
Impedance20–200 Ω
Output Signal (0–1500 W/m²)0–30 mV
Spectral Selectivity (350–1500 nm)<3%
Field of View180°
Operating Environment−40 °C to +80 °C, 0–100% RH
Ingress ProtectionIP67
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKipp & Zonen
OriginNetherlands
ModelSolys 2AP
Tracking Accuracy<0.1° (passive) / <0.02° (active, with optional sun sensor)
Torque>40 Nm
Payload Capacity (balanced)65 kg
Maximum Angular Velocity1.8°/s
Maximum Angular Acceleration3.6°/s
Power Supply24 VDC or 115/230 VAC, 50/60 Hz
Power Consumption50 W (tracker), +100 W (optional heater)
Operating Temperature0–50 °C (standard) / –20–50 °C (with frost cover) / –50–50 °C (with frost cover + heater)
Dimensions (H×W×D)42 × 26 × 38 cm
Weight30 kg
Communication InterfaceRS-232
SoftwareWin2AP (PC-based, user-supplied)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEKO
OriginJapan
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelMP-11
Price RangeUSD 4,200 – 7,000 (FOB)
Automation LevelSemi-Automatic
Effective Test Points per I-V Curve400
Voltage Measurement Accuracy±1% FS
Current Measurement Accuracy±1% FS
Max Voltage Range10–1000 V
Max Current Range0.1–30 A
Power Range10 W–18 kW
Scan Time4–60 ms
Internal Storage Capacity300 I-V curves
Display128×64 LED monochrome LCD (no backlight)
Host Dimensions230 × 320 × 180 mm
Host Weight2.5 kg
Sensor Unit Dimensions210 × 85 × 55 mm
Sensor Unit Weight0.5 kg
Battery8× Ni-MH rechargeable cells (host), 1× 006P (sensor)
ComplianceIEC 61215, IEC 61646, IEC 62446-1, ASTM E1036, UL 1703
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0