Empowering Scientific Discovery

Beijing Chengmeng Weiye Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandChengmeng
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelCM2001
Instrument TypeAutomated Quantitative Concentrator
Temperature RangeAmbient to 95 °C
Temperature Control Accuracy±0.1 °C
Sample Capacity per VialUp to 50 mL
Maximum Parallel Channels60
Heating MethodWater Bath
Gas Control12 Independent Solenoid-Valve-Controlled Channels (5 Nozzles per Channel)
Gas Pressure Range0–0.1 MPa (Adjustable in 0.01 MPa Steps)
External N₂ Supply Requirement0.2–0.8 MPa
Gas Consumption~500 mL/min per nozzle at 0.1 MPa
Auto-ReplenishmentIntegrated Level-Sensing Water Refill System
Safety InterlocksLid-Activated Pause/Resume, Low-Water & Low-Pressure Alarms
DisplayFull-Color Touchscreen Interface
Power Supply220 V / 50 Hz
Dimensions (W×D×H)730 × 500 × 380 mm
Weight30 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandChengmeng
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelCM-24PUS Automated Nitrogen Evaporator
Instrument TypeAutomated Quantitative Sample Concentrator
Temperature RangeAmbient to 100 °C
Temperature Control Accuracy±0.5 °C
Sample Volume Capacity1–200 mL
Sample PositionsUp to 24 parallel channels (configurable: 12/24/36/64 positions)
Heating MethodPID-Controlled Water Bath
Display8-inch HD Touchscreen (800×480 resolution)
Gas ControlElectromagnetic Valves with Real-Time Pressure & Flow Monitoring
Pressure Input Range7–145 psi
Output Pressure Range0–72.5 psi
Power Supply220 V / 110 V, 50 Hz
Rated Power2200 W
End-Point DetectionOptical Fiber Sensors for 0.5 mL and 1.0 mL auto-shutoff
Safety FeaturesLow-water-level alarm, over-temperature cutoff, dry-run protection, auto-drain module
Added to wishlistRemoved from wishlist 0
Add to compare
BrandChengmeng Technology
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelCMDS-12D
Instrument TypeAutomated Quantitative Concentrator
Temperature RangeAmbient to 99 °C
Temperature Control Accuracy±0.5 °C
Sample Vessel Capacity50 mL or 150 mL
Heating MethodDry-block (water bath optional)
Endpoint DetectionOptical sensor per channel
Adjustable Endpoint Volume1.0 mL, 0.5 mL, or near-dry (~0.1 mL)
Nitrogen Pressure Range0–0.1 MPa (adjustable in 0.01 MPa increments)
Inlet Gas Requirement0.2–0.8 MPa
Gas Consumption~500 mL/min per channel at 0.1 MPa
Endpoint Sensitivity10-level optical threshold adjustment
Power Supply220 V / 60 Hz
Dimensions650 × 450 × 308 mm
Weight21 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandChengmeng Technology
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Region of ManufactureDomestic (China)
ModelCMDS-24D
Instrument CategoryAutomated Quantitative Concentrator
Temperature RangeAmbient to 99 °C
Temperature Control Accuracy±0.5 °C
Sample Capacity per Vial150 mL
Heating MethodDry-Block (Water Bath Optional)
Endpoint DetectionOptical Sensor per Channel
Adjustable Endpoint Volumes1.0 mL, 0.5 mL, or Near-Dry (~0.1 mL)
Nitrogen Pressure Control0–0.1 MPa (adjustable in 0.01 MPa increments)
Inlet N₂ Supply Requirement0.2–0.8 MPa (max tolerance: 1.0 MPa)
Gas Consumption~500 mL/min per channel at 0.1 MPa
Endpoint Sensitivity10-Level Adjustable
Dimensions650 × 450 × 308 mm
Weight21 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOrganomation
OriginUSA
ModelS-EVAP-RB Series Parallel Evaporator
Instrument TypeAutomated Quantitative Concentrator
Temperature Range30–100 °C
Temperature Control Accuracy±2 °C
Solvent Bottle Capacity250 mL and 500 mL options
Safety CertificationsUL/cUL Listed
ComplianceISO 14000-compatible operation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandChengmeng
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelChengmeng CM-12PUS Automated Nitrogen Evaporator
Instrument TypeAutomated Quantitative Sample Concentrator
Temperature RangeAmbient to 100 °C
Temperature Control Accuracy±0.5 °C
Sample Volume Capacity per Vial50–150 mL
Maximum Simultaneous Samples64 (configurable: 12/24/36/64 positions)
Nitrogen Input Pressure Range7–145 psi
Output Pressure Range0–72.5 psi
Heating Power2200 W
Display8-inch HD Touchscreen (800×480 resolution)
Sample DetectionOptical Fiber Sensor for Endpoint Detection at 0.5 mL or 1.0 mL
Water Bath MaterialStainless Steel
Control ModesManual & Automatic
ComplianceDesigned for GLP-compliant laboratories
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0