- All
- Favorite
- Popular
- Most rated
| Brand | Accurion |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Halcyonics Workstations |
| Price | Upon Request |
| Load Capacity (Vario Series) | 80–320 kg |
| Load Capacity (Micro Series) | 100–100 kg |
| Isolation Performance | >98.22% at 10 Hz |
| Effective Low-Frequency Cutoff | <5 Hz |
| Interface | USB 1.1 |
| Software | Windows-based Evaluation Suite |
| Dimensions (L×W×H, mm) | Vario_600: 770×770×700 |
| Vario_780 | 990×810×700 |
| Vario_900 | 1110×960×700 |
| Micro_780 | 950×770×700 |
| Micro_1000 | 1070×1170×700 |
| Brand | J.U.M. |
|---|---|
| Origin | Germany |
| Model | 109A-OVE |
| Detection Principle | Flame Ionization Detection (FID) |
| Instrument Type | Online Continuous Analyzer |
| Configuration | Total VOC (TVOC) Monitoring System |
| Measurement Range | 0–1000 ppm (as propane equivalent) |
| Resolution | 0.1 ppm |
| Accuracy | ±5% of reading |
| Response Time (T90) | <60 s |
| Brand | Mercury Instruments |
|---|---|
| Origin | Germany |
| Model | SM-4 Mobile |
| Detection Principle | Cold Vapor Atomic Fluorescence Spectrometry (CVAFS) with Gold Amalgamation Pre-concentration |
| Measurement Range | 0.05–100 µg/m³ (Hg⁰, Hg²⁺, Hgₚ after catalytic conversion) |
| Response Time (t₉₀) | ≤180 s |
| Sample Line Length | Up to 73 m (240 ft) |
| Dilution Ratio | Adjustable, typically 1:10 to 1:100 |
| Operating Temperature | Heated sample path up to 180 °C |
| Compliance | EPA Method 29 / ASTM D6784-22 / EN 14181 QAL1 & QAL3 certified |
| Calibration Options | Integrated NIST-traceable elemental Hg vapor generator (optional), QAL3-compliant ionized Hg⁰ calibration source (optional) |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SM-3 |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Behr CL10 (AOX/EOX/POX) |
| Measurement Principle | Combustion–Microcoulometric Titration |
| Measurement Range | 0.1–3000 mg/L Cl (as Cl⁻ equivalent) |
| Accuracy | <1% RSD |
| Repeatability | <1% RSD |
| Detection Limit | 0.1 µg Cl absolute |
| Resolution | 0.01 µg Cl |
| Carrier Gases | O₂ (99.95%), Ar (99.95% for EOX) |
| IR Furnace Max Temp | 1000 °C |
| Resistive Downstream Furnace Max Temp | 1000 °C |
| Sample Capacity | AOX—up to 200 mL aqueous |
| Analysis Time | 5–10 min per sample (halogen-content dependent) |
| Titration Current Range | 2–450 µA |