BrandAccurion
OriginGermany
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelHalcyonics Workstations
PriceUpon Request
Load Capacity (Vario Series)80–320 kg
Load Capacity (Micro Series)100–100 kg
Isolation Performance>98.22% at 10 Hz
Effective Low-Frequency Cutoff<5 Hz
InterfaceUSB 1.1
SoftwareWindows-based Evaluation Suite
Dimensions (L×W×H, mm)Vario_600: 770×770×700
Vario_780990×810×700
Vario_9001110×960×700
Micro_780950×770×700
Micro_10001070×1170×700
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJ.U.M.
OriginGermany
Model109A-OVE
Detection PrincipleFlame Ionization Detection (FID)
Instrument TypeOnline Continuous Analyzer
ConfigurationTotal VOC (TVOC) Monitoring System
Measurement Range0–1000 ppm (as propane equivalent)
Resolution0.1 ppm
Accuracy±5% of reading
Response Time (T90)<60 s
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMercury Instruments
OriginGermany
ModelSM-4 Mobile
Detection PrincipleCold Vapor Atomic Fluorescence Spectrometry (CVAFS) with Gold Amalgamation Pre-concentration
Measurement Range0.05–100 µg/m³ (Hg⁰, Hg²⁺, Hgₚ after catalytic conversion)
Response Time (t₉₀)≤180 s
Sample Line LengthUp to 73 m (240 ft)
Dilution RatioAdjustable, typically 1:10 to 1:100
Operating TemperatureHeated sample path up to 180 °C
ComplianceEPA Method 29 / ASTM D6784-22 / EN 14181 QAL1 & QAL3 certified
Calibration OptionsIntegrated NIST-traceable elemental Hg vapor generator (optional), QAL3-compliant ionized Hg⁰ calibration source (optional)
Added to wishlistRemoved from wishlist 0
Add to compare
OriginGermany
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelSM-3
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
OriginGermany
Manufacturer TypeAuthorized Distributor
Origin CategoryImported Instrument
ModelBehr CL10 (AOX/EOX/POX)
Measurement PrincipleCombustion–Microcoulometric Titration
Measurement Range0.1–3000 mg/L Cl (as Cl⁻ equivalent)
Accuracy<1% RSD
Repeatability<1% RSD
Detection Limit0.1 µg Cl absolute
Resolution0.01 µg Cl
Carrier GasesO₂ (99.95%), Ar (99.95% for EOX)
IR Furnace Max Temp1000 °C
Resistive Downstream Furnace Max Temp1000 °C
Sample CapacityAOX—up to 200 mL aqueous
Analysis Time5–10 min per sample (halogen-content dependent)
Titration Current Range2–450 µA