Empowering Scientific Discovery

Beijing Chengyi Hengyi Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
OriginGermany
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelBehr S5
Price RangeUSD 14,000 – 28,000
Instrument TypeKjeldahl Nitrogen Determinator
Distillation Time1–99 min
Repeatability≤0.5% CV (RSD ≤1%)
Recovery Rate>99.5%
Power Consumption750–1500 W
Voltage115–230 V~, 50/60 Hz
Cooling Water Flow~5 L/min
Dimensions (W×H×D)410 × 675 × 410 mm
Weight~36 kg
Titration InterfaceRS232
DisplayLCD
Preprogrammed Methods100
Compatible with External TitratorYes
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJ.U.M.
OriginGermany
Model3-200
Detection PrincipleFlame Ionization Detection (FID)
Operating Temperature190 °C (heated sample path & detector chamber)
Response Time< 1 s
FuelHydrogen (low-pressure metal-hydride cartridge, 40 h runtime)
Combustion AirIntegrated air generator (no external cylinder required)
Sample Filtration2 µm stainless steel filter (permanent or replaceable)
Filter CleaningAutomated compressed air or nitrogen back-purge (measurement uninterrupted)
ComplianceEPA Method 25A, EN 12619, ISO 8573-1 (gas purity), GLP/GMP-ready data handling
Added to wishlistRemoved from wishlist 0
Add to compare
OriginGermany
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelBehr InKjel Series (InKjel1210M, InKjel625P, InKjel1225M, InKjel450P, InKjel475M)
Digestion Time Range1–199 min
Repeatability±0.5% RSD
Nitrogen Recovery Rate>99.5%
Power Input750–1500 W (adjustable 0–100% in 1% increments)
Voltage230 VAC / 115 VAC, 50/60 Hz
Dimensions (W × D × H)≈54 × 44 × 75 cm
Weight (incl. reaction tubes)≈20 kg
Added to wishlistRemoved from wishlist 0
Add to compare
OriginGermany
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelBehr B10dN / B22dN / B45dN
Pure Water GradeASTM Type I / ISO 3696 Grade 1
Resistivity18.2 MΩ·cm @ 25°C
Heavy Metals & Soluble Silica< 0.1 ppb
Total Organic Carbon (TOC)< 3 ppb
Microbial Count / Endotoxins< 0.001 EU/mL
Particles (>0.1 µm)< 1 particle/mL
Max. Operating Pressure8 bar
Housing MaterialPolyamide (PA66-GF30)
Exchange Capacity (B10dN/B22dN/B45dN)1.2 / 2.4 / 5.5 kL @ 10 °dH hardness removal
Max. Flow Rate (L/h)300 / 500 / 800
Overall Height (cm)68 / 112 / 125
Housing Height (cm)55 / 98 / 110
Added to wishlistRemoved from wishlist 0
Add to compare
BrandELGA
OriginUnited Kingdom
ModelDI/UV/UF/UVF
Resistivity18.2 MΩ·cm @ 25 °C
Heavy Metals & Soluble Silica<0.1 ppb
Total Organic Carbon (TOC)1–3 ppb
Microbial Count<0.1 CFU/mL
Endotoxins<0.001 EU/mL
Particles (>0.1 µm)<0.2 particles/mL
DNase<0.02 pg/mL
RNase<0.002 ng/mL
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMercury Instruments
OriginGermany
ModelMC3000
Instrument TypePortable
PrincipleCold Vapor Atomic Absorption (CVAA)
Detection Limit≤1 ng/mL
Repeatability≤3% (CVAA method)
Linearity Error5%
Mercury Vapor Output Range15–500 µg/m³ Hg⁰
Calibration MethodNIST-Recommended Mercury Saturated Vapor Pressure Technique
Stabilization Time30 min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDME
OriginDenmark
ModelDS95Navi
Positioning Detection NoiseX-Y < 0.15 nm RMS, Z = 35 pm
Sample DimensionsDiameter < 15 mm, Thickness < 5 mm
Sample Stage Travel Range180 nm × 180 nm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSavillex
OriginUSA
ModelHPX-200-1
Heating Power230 V AC
ControllerIntegrated digital controller
Max Operating Temperature240 °C
Temperature Uniformity±2 °C at 150 °C
Plate Dimensions47.5 cm × 40.4 cm × 14.8 cm
Heating Zone Dimensions415 mm × 212 mm
DisplayLED digital display
Surface MaterialSemiconductor-grade graphite core with full PFA (perfluoroalkoxy alkane) fluoropolymer coating
Edge ProtectionMolded PTFE thermal guard ring
CertificationsTÜV-certified, CE-compliant, RoHS-conformant
Application ClassTrace-metal-clean sample digestion and evaporation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandIMT
OriginGermany
ModelVSP-4000
Instrument TypeDynamic Headspace Sampler
Automation LevelFully Automatic
Sample Vial Heating RangeAmbient to 200 °C
Valve Oven Temperature RangeAmbient to 200 °C
Quantitative Loop Volume1 mL
Sample Capacity80 positions
Vial Format20 mL
Trap ConfigurationSingle Mikro-packed 1/16″ trap
Trap CoolingPeltier-cooled cold trap at −35 °C
Detection Limit≤0.1 ppt (for selected VOCs)
Thermal Desorption Max TempUp to 280 °C (field-upgradable)
Optional FeaturesInternal Standard Addition Module, Split Flow up to 50 mL/min, Foam Sensor, Integrated Pressure & Mass Flow Control
Added to wishlistRemoved from wishlist 0
Add to compare
OriginGermany
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelKEX Compact Soxhlet Extraction System
PricingAvailable Upon Request
Voltage230 VAC / 115 VAC
Frequency50/60 Hz
Current3 A / 6 A
Power Rating450 W
Weight~7.5 kg
Dimensions (W×D×H)~23 × 33 × 71.5 cm (KEX 30) / ~23 × 33 × 80 cm (KEX 100)
Extraction Vessel Capacity30–500 mL
Sample Throughput1 sample per unit (compact configuration)
Condenser InterfaceStandard threaded joint (compatible with Weibull/Stoldt acid hydrolysis units)
Drain ValveIntegrated piston valve for post-extraction solvent transfer
Cooling RequirementCompatible with UK 12/400 recirculating chiller (380 W)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCHINYEE
OriginJapan
ModelNT-6100A
ComplianceUSP <711>, <724>, <1092>
Apparatus TypePaddle (App. 2)
Vessel Capacity900–1000 mL
Temperature Control Range30–45 °C (±0.2 °C stability)
Rotation Speed25–250 rpm (±1 rpm accuracy)
Number of Vessels6
InterfaceRS-232C, optional USB/Ethernet upgrade
Calibration SupportUSP Calibrator Tablets (Prednisone, Salicylic Acid), mechanical verification tools included
Drive ArchitectureMonolithic shaft coupling with one-touch bath cover release
Vessel PositioningCentered alignment via precision-machined guide rails
TraceabilityIndividual serialized vessels, paddles, and shafts
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJ.U.M.
OriginGermany
ModelAeroFid60 Aerosol Can Gas Leak Detection System
CategoryPhysical Property Testing Instruments — Other Physical Property Testing Instruments
Import StatusImported
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSavillex
OriginUSA
Model850-011-100706
MaterialPerfluoroalkoxy (PFA)
ConfigurationDual-channel nebulizer spray chamber assembly with detachable O-ring sealed end cap, integrated make-up gas port, 6 mm OD nebulizer inlet, PFA drain connector kit, quartz torch, PFA injection tube, support stand, and pre-cleaned components (pre-rinsed in high-purity HNO₃/HF)
ComplianceCompatible with Thermo Scientific Element 2 HR-ICP-MS and Neptune MC-ICP-MS platforms
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMercury Instruments
OriginGermany
Model3000XS
Instrument TypePortable
Measurement PrincipleCold Vapor Atomic Absorption Spectrometry (CVAAS)
Detection Limit≤0.1 µg/m³
Repeatability≤1.0%
Linearity Error±1%
Wavelength253.7 nm
Light SourceElectrodeless Discharge Lamp (EDL)
Response Time (99% signal)1 s
Sensitivity0.1 µg/m³ (0.01 ppb)
Measurement Ranges0–100, 0–1000, 0–2000 µg/m³
Data Logger Capacity10,000 readings
Power SupplyRechargeable NiMH battery (6 h operation), 12 V DC input, 100–240 V AC (50/60 Hz)
Weight~5 kg (with battery)
DisplayBacklit graphical LCD
Output InterfacesUSB, RS232, 4–20 mA analog output
HousingCorrosion-resistant ABS with IP65-rated connectors
PumpMaintenance-free diaphragm pump
FilterIntegrated particulate filter at probe inlet
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSavillex
OriginUSA
ModelC-Flow
Flow Rates50 µL/min and 200 µL/min
MaterialPerfluoroalkoxy (PFA)
ComplianceCompatible with Scott-type spray chambers (35 mm), O-ring-free design
CertificationManufactured under ISO 9001-certified processes, compliant with ASTM D5673 and USP <232>/<233> for trace metal analysis
Added to wishlistRemoved from wishlist 0
Add to compare
OriginGermany
Manufacturer TypeDistributor
Origin CategoryImported
ModelBehr Metal Guarded Heating Mantle
PricingUpon Request
KP1Ø90 mm, 500 W, 230 V
KP2Ø145 mm, 1100 W, 230 V
Weight (KP1)~1.2 kg
Weight (KP2)~1.3 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRocklabs
OriginNew Zealand
Product TypeCertified Reference Material (CRM)
Matrix TypesOxide, Sulphide, Siliceous
Certified ElementsPt (0.456–4.749 ppm), Pd (0.563–5.918 ppm), Au (0.0798–30.49 ppm), Ag (60.2–153.9 ppm)
Uncertainty95% confidence intervals reported for all certified values
Blank LevelsAu < 0.002 ppm
Packaging2.5 kg jars, 30 g & 50 g sachets (varies by material)
CertificationISO/IEC 17034-accredited, recognized by IAG (International Association of Geoanalysts)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSavillex
OriginUSA
ModelDST-1000A
Instrument TypeSub-boiling Distiller
Heating MethodResistive Heating (Corrosion-Resistant Heater Sleeve)
Cooling MethodNatural Air Cooling
Distillation Rate1000 mL/24 h
Warm-up Time30 min
Endpoint ControlManual
Heating ElementCorrosion-Resistant PFA-Encapsulated Heater Sleeve
Power Input70 W
Voltage Options100/115/230 VAC ±10%, 50/60 Hz
Dimensions (L×W×H)20 × 20 × 43 cm (excl. funnel)
Weight4.6 kg
Maximum Capacity1 L
Material of Wetted PartsInjection-Molded PFA
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSavillex
OriginUSA
Manufacturer Authorization StatusAuthorized Distributor
Origin CategoryImported
Model No.850-011-100787
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
OriginGermany
Manufacturer TypeAuthorized Distributor
Product OriginImported
ModelBehr STI
Price RangeUSD 14,000 – 28,000
Instrument TypeKjeldahl Nitrogen Analyzer System
Distillation Time1–99 minutes
Repeatability±0.5% RSD
Nitrogen Recovery Rate>99.5%
Power Consumption750–1500 W
Input Voltage230 VAC / 115 VAC
Frequency50/60 Hz
Net Weight~3.5 kg
Dimensions (W × D × H)~33 × 20 × 60 cm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMercury Instruments
OriginGermany
ModelMMS-NG
Instrument TypeOnline Analyzer
Measurement PrincipleCold Vapor Atomic Absorption Spectroscopy (CVAAS)
Detection Limit≤0.1 ng/m³
Repeatability≤1.0% (CVAAS)
Linearity Error±1% (CVAAS)
Measurement Range0.001–50 µg/m³ (extendable to 2000 µg/m³ with integrated dilution system)
Wavelength253.7 nm
Sample Inlet Pressureup to 240 bar (3480 psi)
Sampling Points2–16 via multiplexed valve manifold
Cycle Time~3 minutes per point
Calibration MethodSaturated mercury vapor generation (NIST-recommended vapor pressure equation)
CertificationsATEX 2G IIC T4 EEx p, IECEx, ISO/DIS 6978-3, ASTM D5954, VDI 2267 Part 8, ISO 6978-1
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMercury Instruments
OriginGermany
ModelSM-4 Mobile
Measurement PrincipleThermal Catalytic Conversion + Gold Amalgamation Cold Vapor Atomic Fluorescence (CVAFS)
Detection Limit0.05 µg/m³
Response Time (t₉₀)~180 s
Sample Line LengthUp to 73 m (240 ft)
Dilution RatioAdjustable, up to 1:100
ComplianceEU EN 15267-3 certified, US EPA Performance Specification 12A (PS-12A) and RATA validated
Calibration OptionsAutomated Hg⁰ and Hg²⁺ gas generators (NIST-traceable), QAL3-compliant auto-validation module
Waste GenerationZero liquid or solid waste
Operating Temperature RangeProbe heated to >180 °C
FilterHeated particulate filter with automatic air-purge cleaning
Added to wishlistRemoved from wishlist 0
Add to compare
BrandELGA
OriginUnited Kingdom
ModelQuest / Quest UV
Purified Water GradeASTM Type I (Ultra-pure), Type II (Pure), Type III (RO)
Resistivity18.2 MΩ·cm at 25 °C
Heavy Metals & Soluble Silica< 0.1 ppb
Total Organic Carbon (TOC)< 5 ppb
Microbial Count< 0.001 CFU/mL
Endotoxins< 0.001 EU/mL
Particles (>0.1 µm)< 1 particle/mL
RO Feed Flow RateUp to 10 L/h
Dispense Flow RateUp to 1.2 L/min
Integrated Reservoir7 L (internal), optional external tanks: 15 L or 30 L
Dimensions (W × D × H)23.2 cm × 34 cm × 51 cm
ComplianceMeets ISO 3696:1987, ASTM D1193-06, CLSI EP21-A, and USP <1231> for purified water
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMercury Instruments
OriginGermany
Model3000XS
Instrument TypePortable
Measurement PrincipleCold Vapor Atomic Absorption Spectrometry (CVAAS)
Detection Limit0.1 µg/m³
Repeatability≤3.0%
Linearity Error±10%
Measurement Ranges0–100 / 0–1000 / 0–2000 µg/m³
Resolution0.1 µg/m³
UV SourceElectrodeless Low-Pressure Mercury Lamp (253.7 nm)
Optical CellHigh-Purity Fused Silica
Pump TypeMaintenance-Free Diaphragm Pump
Battery LifeUp to 6 Hours
Data LoggingIntegrated Recorder
ComplianceDesigned for ISO 15202, ASTM D6784, and EPA Method 29–compliant field deployment
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0