Empowering Scientific Discovery

Beijing Huayun Analytical Instrument Research Institute Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuayun
OriginBeijing, China
Manufacturer TypeManufacturer
Product CategoryDomestic
ModelGXH-3010/3011BF
Instrument TypePortable
Detection TargetMulti-component
Minimum Range(0–50.0) × 10⁻⁶ CO, 0–0.500% CO₂
Repeatability≤1% FS
Resolution0.1 × 10⁻⁶ CO
Response TimeCO: t₀–t₉₀ ≤45 s
CO₂t₀–t₉₀ ≤15 s
Zero Drift≤±2% FS/h
Span Drift≤±2% FS/3 h
Linearity Error≤±2% FS
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuayun Instruments
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
ModelGXH-3010E
Measurement PrincipleNon-Dispersive Infrared (NDIR)
Detection Range0–0.500% or 0–1.000% CO₂ (customizable)
Resolution0.001%
Repeatability≤1% FS
Zero Drift≤±2% FS/h
Span Drift≤±2% FS/3h
Temperature Error≤±2% FS/10°C (10–45°C)
CO Interference≤±0.3% FS at 1250 mg/m³ CO
Warm-up Time≤10 min
Response Time (t₀–t₉₀)≤15 s
Sample Flow Rate0.5–1.0 L/min
Power SupplyAC 220 V (±10%) or rechargeable internal battery
Dimensions210 × 165 × 85 mm
Weight≤2.0 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuayun
ModelGXH-3010D
TypeNDIR-based Fixed Gas Analyzer
Measurement PrincipleGas Filter Correlation (GFC) Infrared Spectroscopy
MeasurandsCO, CO₂, Hydrocarbons (HC)
Range0–100% vol (user-selectable sub-ranges)
Repeatability≤1% FS
Warm-up Time≤30 min
Response Time (T90)≤10 s
Output4–20 mA analog + RS-232/RS-485 digital interface
Temperature ControlInternal thermostatic stabilization
ComplianceJJG 635–1999, GB/T 18204.24–2000
EnclosureCustomizable compact chassis (standard or application-specific rackmount)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuayun
OriginBeijing, China
Manufacturer TypeManufacturer
Product CategoryDomestic
ModelGXH-3011N
Instrument TypeOnline
Detection TargetSingle-component
Minimum RangeCO (0–500) × 10⁻⁶
Repeatability≤ ±1% FS
Resolution≤ ±1% FS
Response Timet₀–t₉₀ ≤ 30 s (from sample gas entry)
Zero Drift≤ ±2% FS / 72 h
Span Drift≤ ±2% FS / 72 h
Linearity Error≤ ±2% FS
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuayun
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelGXH-3010H (with One-Touch Zero Calibration)
Instrument TypePortable
Detection TargetSingle-Component Gas
Measurement Range0–0.500% CO₂ (expandable to 0–1.000%)
Repeatability≤1% of Full Scale
Resolution0.001%
Response Time (t₀–t₉₀)≤15 s
Zero Drift≤±2% FS/h
Span Drift≤±2% FS/3 h
Linearity Error≤±2% FS
Sampling MethodIntegrated Pump-Aspiration
Flow Rate0.5–1.0 L/min
Warm-up Time≤10 min
Operating Temperature10–45 °C
CO Interference≤±0.3% FS at 1250 mg/m³ CO
Power SupplyAC 220 V (±10%) or Rechargeable Li-ion Battery
Dimensions200 × 95 × 35 mm
Weight≤500 g
ComplianceGB/T 18204.2–2014, GBZ/T 300.37–2017, JJG 635–2011
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuayun Instruments
OriginBeijing, China
Manufacturer TypeOEM Manufacturer
Country of OriginChina
ModelHY-3000
Instrument TypeOnline Fixed-Mount System
Target AnalyteSingle-Component Gas
Measurement Range (Minimum)0–50 ppm
Repeatability≤1% F.S.
Resolution0.1 ppm
Response Time≤60 s
Zero Drift≤±5% F.S.
Span Drift≤±1% F.S.
Linearity Error≤±2% F.S.
Added to wishlistRemoved from wishlist 0
Add to compare
KeyOrigin: Imported
Manufacturer TypeDistributor
ModelLD-3C
Measurement PrincipleLight Scattering (Laser Nephelometry)
Safety RatingNon-explosion-proof
Range (Low)0.01–100 mg/m³
Range (High)0.001–10 mg/m³
Sensitivity (L)1 CPM = 0.01 mg/m³
Sensitivity (H)1 CPM = 0.001 mg/m³
Sampling Time Options0.1, 1, 2, 5, 10 min + manual mode
Accuracy±10%
Dimensions192 × 69 × 140 mm
Weight1.4 kg
ComplianceWS/T 206–2001, LD 98–1996, TB/T 2323–92
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuayun Instruments
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelGXH-3010/3011BF
Instrument TypePortable
Detection TargetMulti-component (CO & CO₂)
Minimum RangeCO: 0–50 ppm
CO₂0–0.500%
Repeatability≤1% F.S.
ResolutionCO: 0.1 ppm
CO₂0.001%
Response Time≤15 s (CO₂), ≤45 s (CO)
Zero Drift≤±2% F.S./4 h
Span Drift≤±2% F.S./4 h
Linearity Error≤±2% F.S.
Operating Temperature Range10–45 °C
Flow Rate0.5–1.2 L/min
Data Storage CapacityUp to 5000 records
InterfaceUSB with proprietary data transfer software
Power SupplyAC 220 V (±10%) or rechargeable internal battery
Dimensions270 × 230 × 90 mm
Weight≤3.5 kg
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelLD-5C
Price¥27,800
Sampling MethodReal-time Laser Scattering with Optional Filter-Based Gravimetric Validation
Particle Size SelectivityPM₁₀ / PM₅ / PM₂.₅ via Interchangeable Impactors
Concentration RangeLD-5C(L): 0.01–100 mg/m³
LD-5C(H)0.001–10 mg/m³
Detection LimitLD-5C(L): 0.1 mg/m³
LD-5C(H)0.001 mg/m³
DisplayBacklit LCD with Chinese Character Menu
Data Storage99 Cyclic Records
Sampling DurationConfigurable from 0.1 min to user-defined intervals (1–9999 s)
Communication InterfacesRS232 Serial Port, Thermal Printer Output, 0–1 V Analog Output, Digital TTL-Level Output
Power SupplyRechargeable Ni-MH Battery (8 h continuous operation), AC/DC Adapter Included
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuayun
OriginBeijing, China
Manufacturer TypeManufacturer
Country of OriginDomestic (China)
ModelGXH-3010/3011AE
Instrument TypePortable
Detection TargetMulti-component
Minimum Range0–50 ppm
Repeatability≤1% F.S.
Resolution0.1 ppm
Response Time≤30 s
Zero Drift≤±2% F.S./4 h
Span Drift≤±2% F.S./4 h
Linearity Error≤±2% F.S.
Measurement PrincipleNon-Dispersive Infrared (NDIR)
Sampling MethodBuilt-in Pump-aspiration
Flow Rate0.5–1.2 L/min
Power SupplyAC 220 V (±10%) or Rechargeable Battery
Dimensions260 × 210 × 90 mm
Weight≤3.5 kg
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
Model1027
Sampling MethodActive (Pump-Driven)
Measurement Range0.1–999 pCi/L (3.7–37,000 Bq/m³)
Minimum Detectable Concentration0.1 pCi/L
Sensitivity2.5 counts per hour per pCi/L (cph/pCi/L)
Accuracy±25% or ±1 pCi/L (whichever is greater)
Display3-digit LCD
Power Supply220 VAC / 9 VDC adapter
Dimensions200 × 120 × 65 mm
Weight0.9 kg
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
ModelHY-3000
Instrument TypeContinuous Emission Monitoring System (CEMS)
Measurement Repeatability<1%
Response Time30 s
Measured GasesCO, CO₂, CH₄, O₂
Added to wishlistRemoved from wishlist 0
Add to compare
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (PRC)
ModelML-91
PriceUSD 950 (FOB Jiangsu)
Operating Temperature−10 °C to +40 °C
Relative Humidity66 % ±15 % RH
Atmospheric Pressure750 mmHg ±30 mmHg
Frequency Band3–33 cm (i.e., 0.9–10 GHz)
Power Density Range0.2 µW/cm² to 20 mW/cm²
Display3-digit LED, auto-ranging across 200 µW/cm² / 2 mW/cm² / 20 mW/cm² scales with LED range indicators
Alarm ThresholdAdjustable, default ≥5 mW/cm²
Calibration Field Accuracy±0.75 dB
Full-Scale Indication Error (at rated voltage)≤±1.5 %
Indicator Dimensions82 mm × 40 mm × 172 mm
Net Weight0.8 kg
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
Model4160-2
PriceUSD 3,650 (FOB)
PrincipleElectrochemical Sensor
Measurement Range0–19.99 ppm
Extended Low-Range Mode0–500 ppb
Resolution0.01 ppm
Accuracy±2% Rd ±0.01 ppm
Flow Rate1.0 L/min
Dimensions178 × 102 × 225 mm
Weight2.0 kg
PowerRechargeable Li-ion battery with real-time voltage monitoring
CertificationChina NIM Type Approval (Certificate No. 2021F012), Evaluated by Chinese Center for Disease Control and Prevention – Institute of Environmental Health and Related Product Safety
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuayun Instruments
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Product TypeOnline Fixed-Mount Analyzer
PrincipleNon-Dispersive Infrared (NDIR) Absorption
Response TimeT₀–T₉₀ ≤ 15 s (from sample gas entry)
Repeatability≤ ±1% FS for CO, CO₂, CH₄
Linearity Error≤ ±2% FS
Zero Drift≤ ±2% FS / 72 h
Span Drift≤ ±2% FS / 72 h
Measurement RangesCO (0–500) ppm, CO₂ (0–500) ppm, CH₄ (0–1000) ppm
Output Signal4–20 mA analog
Power Supply220 VAC ±10%, 50 Hz ±10%
Dimensions436 × 426 × 133 mm (L×W×H, excluding protrusions)
Weight≤10 kg
Operating Temperature5–45 °C
Relative Humidity≤80% RH (non-condensing)
Environmental RequirementsNon-corrosive atmosphere, airflow ≤0.5 m/s, vibration-free horizontal mounting
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Product OriginDomestic (PRC)
ModelHY-3000
Instrument TypeOnline Continuous Emission Monitoring System (CEMS)
Target GasesCO, CO₂, CH₄, O₂, SO₂, H₂
Response Time≤30 s
Zero Drift±2% FS / 48 h
Span Drift±2% FS / 48 h
Linearity Error±2% FS
O₂ Range Options0–2% or 0–25% vol
H₂ Range Options0–5% or 0–100% vol
CO Range0–5000 ppm (expandable)
CO₂/CH₄/SO₂ Ranges0–500 ppm / 0–500 ppm / 0–2000 ppm (all expandable)
Added to wishlistRemoved from wishlist 0
Add to compare
OriginChina
Manufacturer TypeDistributor
ModelHS6288B
PriceUSD 1,390 (FOB)
Frequency Range31.5 Hz – 8 kHz
Sound Pressure Level Range35–130 dB(A), 40–130 dB (Linear)
Self-Noise<20 dB(A)
Time WeightingFast (F), Slow (S), Max Hold
Measurement FunctionsLeq, LAE, LN (L10/L50/L90), Lmin, Lmax, SD, Ld, Ln, Ldn
Measurement DurationsManual trigger, 10 s, 1 min, 5 min, 10 min, 20 min, 1 h, 8 h, 24 h, and full-hour synchronized logging
Display54 × 42 mm LCD with analog bar graph, real-time time stamp, measurement mode indicator, and 1/1-octave center frequency readout
InterfaceRS-232 serial port for PC connectivity and data export
Standard AccessoriesHS6288B(D) main unit, 4784A thermal printer (with charger), mounting bracket, software CD, thermal paper roll, 18″ protective carrying case, windscreen, screwdriver
Optional Accessories5 m / 10 m extension cables, Class 1 acoustic calibrator (e.g., HS6020)
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (PRC)
ModelHD-2000
PriceUSD 1,240 (FOB)
Measurement Range0.01–100 µGy/h
Energy Threshold60 keV
Linearity (r vs. CPS)≥0.999
Stability≤6%
Accuracy±20%
Sensitivity≥350 cps at 1 µGy/h
Power Consumption≤100 mW
Operating Temperature0–40 °C
Relative Humidity≤90% @ 40 °C
Weight6 kg
Dimensions35 × 20 × 25 cm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuayun Instruments
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelHY-400 (New)
PriceUSD 5,600 (FOB Beijing)
Temperature Control Accuracy±0.1 °C
Setpoint Range–20 °C to +10 °C (factory default: 4 °C)
Dimensions (W×H×D)484 × 178 × 320 mm
Gas Path MaterialPTFE-lined stainless steel
Cooling MethodStaged refrigeration + condensate aggregation
MountingPanel-mount (19″ rack compatible)
Liquid Level Alarm OutputDry contact relay (NO/NC configurable)
Integrated Pump MountingYes (for sampling pump & peristaltic drain pump)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuayun Instruments
OriginBeijing, China
Manufacturer TypeOEM Manufacturer
Regional OriginDomestic (China)
ModelGXH-3010F
PriceUpon Request
Measurement PrincipleNon-Dispersive Infrared (NDIR)
Standard Range0–5000 ppm or 0–10000 ppm CO₂
Response Time≤10 s
Linearity≤±2% FS
Repeatability≤1% FS
Power SupplyAC 220 V / Internal Rechargeable Battery
Weight≤3 kg
Dimensions248 mm × 185 mm × 85 mm
Optional AccessoriesRS232 Interface, Real-Time Data Acquisition & Processing Software
Customization OptionsAlternate Ranges, Integrated Temperature Sensor, O₂ Sensor (for Controlled Atmosphere Storage), Leaf Chamber Integration (Agricultural CO₂ Monitoring), Soil Probe Integration (Soil Respiration Studies)
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (PRC)
ModelGXH-3010E
Instrument TypePortable
Detection TargetSingle-component (CO₂)
Measurement Range0–0.500% v/v (configurable to 0–1.000%)
Repeatability≤1.0% FS
Resolution0.001% v/v
Response Time (t₀–t₉₀)≤15 s
Zero Drift≤±2% FS/h
Span Drift≤±2% FS/3 h
Linearity Error≤±2% FS
CO Interference≤±0.3% FS at 1250 mg/m³ CO
Temperature Effect≤±2% FS/10°C (10–45°C)
Warm-up Time≤10 min
Sample Flow Rate0.5–1.0 L/min
Power SupplyAC 220 V ±10% or rechargeable Li-ion battery
Dimensions210 × 165 × 85 mm
Weight≤2.0 kg
Added to wishlistRemoved from wishlist 0
Add to compare
OriginChina
TypePortable
Measurement Range60–140 dB (re 10⁻⁶ m/s²)
Frequency Range1–80 Hz
Frequency WeightingsWhole-body vertical (VLz), whole-body horizontal (VLx-y), linear (VAL)
Dimensions (main unit)24 × 8.1 × 3.1 cm
Weight (main unit)0.4 kg
Data Storage Capacity127 measurement sets
ComplianceISO 2631-1, ISO 5349-1, and IEC 61260 Class 2 requirements for vibration meters
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelIFC-2
PriceUSD 690 (FOB Beijing)
Flow Rate Range5–25 L/min (continuously adjustable)
Timer Range0–99 minutes
Power SupplyAC 220 V / DC rechargeable battery (≥3 h continuous operation)
Dimensions210 × 130 × 90 mm
Explosion ProtectionIntrinsic Safety “ib I” per GB 3836.4–2021 / IEC 60079-11
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuayun
OriginBeijing, China
Manufacturer TypeManufacturer
Product CategoryDomestic
ModelGXH-3010F
Instrument TypePortable
Detection TargetSingle-component gas
Measurement Range0–0.500% CO₂ (customizable up to 0–20.00%)
Repeatability≤1% FS
Resolution0.001% CO₂
Response Timet₀–t₉₀ ≤15 s
Zero Drift≤±2% FS/h
Span Drift≤±2% FS/3 h
Linearity Error≤±2% FS
Temperature Effect≤±2% FS/10°C (10–45°C)
CO Interference≤±0.3% FS at 1250 mg/m³ CO
Power SupplyAC 220 V (±10%) or internal rechargeable battery
Dimensions255 × 215 × 92 mm
Weight≤3.2 kg
Show next